Madeline Hess
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Madeline Hess has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Sharmila Majumdar
Department of Radiology and Biomedical Imaging University of California San Francisco California USA
3 shared publicationsValentina Pedoia
Department of Radiology and Biomedical Imaging University of California San Francisco California USA
3 shared publicationsKenneth T Gao
Department of Radiology and Biomedical Imaging, University of California, San Francisco , San Francisco, CA, United States
2 shared publicationsAbel Torres‐Espin
School of Public Health Sciences Faculty of Health University of Waterloo Waterloo Ontario Canada
1 shared publication- Abhejit Rajagopal
Department of Radiology and Biomedical Imaging, University of California-San Francisco, San Francisco, CA 94158, USA
1 shared publication - Avantika Sinha
Department of Radiology and Biomedical Imaging, University of California-San Francisco, San Francisco, CA 94158, USA
1 shared publication
Latest Publications
- Open Access
- 22 February 2025
- Published by MDPI AG in Tomography
- Vol. 11 (3) , 21
Deep Learning-Based Tumor Segmentation of Murine Magnetic Resonance Images of Prostate Cancer Patient-Derived Xenografts
Background/Objective: Longitudinal in vivo studies of murine xenograft models are widely utilized in oncology to study cancer biology and develop therapies. Magnetic resonance imaging (MRI) of these tumors is an invaluable tool for monitoring tumor growth and characterizing the tumors as well. Methods: In this work, a pipeline for automating the segmentation of xenografts in mouse models was developed. T2-weighted (T2-wt) MRI images from mice implanted with six different prostate cancer patient-derived xenografts (PDX) in the kidneys, liver, and tibia were used. The segmentation pipeline included a slice classifier to identify the slices that had tumors and subsequent training and validation using several U-Net-based segmentation architectures. Multiple combinations of the algorithm and training images for different sites were evaluated for inference quality. Results and Conclusions: The slice classifier network achieved 90% accuracy in identifying slices containing tumors. Among the various segmentation architectures tested, the dense residual recurrent U-Net achieved the highest performance in kidney tumors. When evaluated across the kidneys, tibia, and liver, this architecture performed the best when trained on all data as compared to training on only data from a single site (and inferring on a multi-site tumor images), achieving a Dice score of 0.924 across the test set.
- 22 February 2025
- Published by MDPI AG in Tomography
- Vol. 11 (3) , 21
Open AccessDeep Learning-Based Tumor Segmentation of Murine Magnetic Resonance Images of Prostate Cancer Patient-Derived Xenografts
Background/Objective: Longitudinal in vivo studies of murine xenograft models are widely utilized in oncology to study cancer biology and develop therapies. Magnetic resonance imaging (MRI) of these tumors is an invaluable tool for monitoring tumor growth and characterizing the tumors as well. Methods: In this work, a pipeline for automating the segmentation of xenografts in mouse models was developed. T2-weighted (T2-wt) MRI images from mice implanted with six different prostate cancer patient-derived xenografts (PDX) in the kidneys, liver, and tibia were used. The segmentation pipeline included a slice classifier to identify the slices that had tumors and subsequent training and validation using several U-Net-based segmentation architectures. Multiple combinations of the algorithm and training images for different sites were evaluated for inference quality. Results and Conclusions: The slice classifier network achieved 90% accuracy in identifying slices containing tumors. Among the various segmentation architectures tested, the dense residual recurrent U-Net achieved the highest performance in kidney tumors. When evaluated across the kidneys, tibia, and liver, this architecture performed the best when trained on all data as compared to training on only data from a single site (and inferring on a multi-site tumor images), achieving a Dice score of 0.924 across the test set.
- Open Access
Thresholding approaches for estimating paraspinal muscle fat infiltration using T1 ‐ and T2 ‐weighted MRI : Comparative analysis using water–fat MRI
Background: Paraspinal muscle fat infiltration is associated with spinal degeneration and low back pain, however, quantifying muscle fat using clinical magnetic resonance imaging (MRI) techniques continues to be a challenge. Advanced MRI techniques, including chemical‐shift encoding (CSE) based water–fat MRI, enable accurate measurement of muscle fat, but such techniques are not widely available in routine clinical practice. Methods: To facilitate assessment of paraspinal muscle fat using clinical imaging, we compared four thresholding approaches for estimating muscle fat fraction (FF) using T1‐ and T2‐weighted images, with measurements from water–fat MRI as the ground truth: Gaussian thresholding, Otsu's method, K‐mean clustering, and quadratic discriminant analysis. Pearson's correlation coefficients ( r ), mean absolute errors, and mean bias errors were calculated for FF estimates from T1‐ and T2‐weighted MRI with water–fat MRI for the lumbar multifidus (MF), erector spinae (ES), quadratus lumborum (QL), and psoas (PS), and for all muscles combined. Results: We found that for all muscles combined, FF measurements from T1‐ and T2‐weighted images were strongly positively correlated with measurements from the water–fat images for all thresholding techniques ( r = 0.70–0.86, p < 0.0001) and that variations in inter‐muscle correlation strength were much greater than variations in inter‐method correlation strength. Conclusion: We conclude that muscle FF can be quantified using thresholded T1‐ and T2‐weighted MRI images with relatively low bias and absolute error in relation to water–fat MRI, particularly in the MF and ES, and the choice of thresholding technique should depend on the muscle and clinical MRI sequence of interest.
Open AccessThresholding approaches for estimating paraspinal muscle fat infiltration using T1 ‐ and T2 ‐weighted MRI : Comparative analysis using water–fat MRI
Background: Paraspinal muscle fat infiltration is associated with spinal degeneration and low back pain, however, quantifying muscle fat using clinical magnetic resonance imaging (MRI) techniques continues to be a challenge. Advanced MRI techniques, including chemical‐shift encoding (CSE) based water–fat MRI, enable accurate measurement of muscle fat, but such techniques are not widely available in routine clinical practice. Methods: To facilitate assessment of paraspinal muscle fat using clinical imaging, we compared four thresholding approaches for estimating muscle fat fraction (FF) using T1‐ and T2‐weighted images, with measurements from water–fat MRI as the ground truth: Gaussian thresholding, Otsu's method, K‐mean clustering, and quadratic discriminant analysis. Pearson's correlation coefficients ( r ), mean absolute errors, and mean bias errors were calculated for FF estimates from T1‐ and T2‐weighted MRI with water–fat MRI for the lumbar multifidus (MF), erector spinae (ES), quadratus lumborum (QL), and psoas (PS), and for all muscles combined. Results: We found that for all muscles combined, FF measurements from T1‐ and T2‐weighted images were strongly positively correlated with measurements from the water–fat images for all thresholding techniques ( r = 0.70–0.86, p < 0.0001) and that variations in inter‐muscle correlation strength were much greater than variations in inter‐method correlation strength. Conclusion: We conclude that muscle FF can be quantified using thresholded T1‐ and T2‐weighted MRI images with relatively low bias and absolute error in relation to water–fat MRI, particularly in the MF and ES, and the choice of thresholding technique should depend on the muscle and clinical MRI sequence of interest.
- Open Access
- 21 March 2023
- Published by Oxford University Press (OUP) in Pain Medicine
- Vol. 24 (Supplement) , S149-S159
Technology and Tool Development for BACPAC: Qualitative and Quantitative Analysis of Accelerated Lumbar Spine MRI with Deep-Learning Based Image Reconstruction at 3T
To evaluate whether combining fast acquisitions with deep-learning reconstruction can provide diagnostically useful images and quantitative assessment comparable to standard-of-care acquisitions for lumbar spine magnetic resonance imaging (MRI). Eighteen patients were imaged with both standard protocol and fast protocol using reduced signal averages, each protocol including sagittal fat-suppressed T2-weighted, sagittal T1-weighted, and axial T2-weighted 2D fast spin-echo sequences. Fast-acquisition data was additionally reconstructed using vendor-supplied deep-learning reconstruction with three different noise reduction factors. For qualitative analysis, standard images as well as fast images with and without deep-learning reconstruction were graded by three radiologists on five different categories. For quantitative analysis, convolutional neural networks were applied to sagittal T1-weighted images to segment intervertebral discs and vertebral bodies, and disc heights and vertebral body volumes were derived. Based on noninferiority testing on qualitative scores, fast images without deep-learning reconstruction were inferior to standard images for most categories. However, deep-learning reconstruction improved the average scores, and noninferiority was observed over 24 out of 45 comparisons (all with sagittal T2-weighted images while 4/5 comparisons with sagittal T1-weighted and axial T2-weighted images). Interobserver variability increased with 50 and 75% noise reduction factors. Deep-learning reconstructed fast images with 50% and 75% noise reduction factors had comparable disc heights and vertebral body volumes to standard images (r2 0.86 for disc heights and r2 0.98 for vertebral body volumes). This study demonstrated that deep-learning-reconstructed fast-acquisition images have the potential to provide noninferior image quality and comparable quantitative assessment to standard clinical images.- 21 March 2023
- Published by Oxford University Press (OUP) in Pain Medicine
- Vol. 24 (Supplement) , S149-S159
Open AccessTechnology and Tool Development for BACPAC: Qualitative and Quantitative Analysis of Accelerated Lumbar Spine MRI with Deep-Learning Based Image Reconstruction at 3T
To evaluate whether combining fast acquisitions with deep-learning reconstruction can provide diagnostically useful images and quantitative assessment comparable to standard-of-care acquisitions for lumbar spine magnetic resonance imaging (MRI). Eighteen patients were imaged with both standard protocol and fast protocol using reduced signal averages, each protocol including sagittal fat-suppressed T2-weighted, sagittal T1-weighted, and axial T2-weighted 2D fast spin-echo sequences. Fast-acquisition data was additionally reconstructed using vendor-supplied deep-learning reconstruction with three different noise reduction factors. For qualitative analysis, standard images as well as fast images with and without deep-learning reconstruction were graded by three radiologists on five different categories. For quantitative analysis, convolutional neural networks were applied to sagittal T1-weighted images to segment intervertebral discs and vertebral bodies, and disc heights and vertebral body volumes were derived. Based on noninferiority testing on qualitative scores, fast images without deep-learning reconstruction were inferior to standard images for most categories. However, deep-learning reconstruction improved the average scores, and noninferiority was observed over 24 out of 45 comparisons (all with sagittal T2-weighted images while 4/5 comparisons with sagittal T1-weighted and axial T2-weighted images). Interobserver variability increased with 50 and 75% noise reduction factors. Deep-learning reconstructed fast images with 50% and 75% noise reduction factors had comparable disc heights and vertebral body volumes to standard images (r2 0.86 for disc heights and r2 0.98 for vertebral body volumes). This study demonstrated that deep-learning-reconstructed fast-acquisition images have the potential to provide noninferior image quality and comparable quantitative assessment to standard clinical images. - Open Access
- 31 October 2022
- Published by Oxford University Press (OUP) in Pain Medicine
- Vol. 24 (Supplement) , S139-S148
Deep Learning for Multi-Tissue Segmentation and Fully Automatic Personalized Biomechanical Models from BACPAC Clinical Lumbar Spine MRI
Study Design: In vivo retrospective study of fully automatic quantitative imaging feature extraction from clinically acquired lumbar spine magnetic resonance imaging (MRI). Objective: To demonstrate the feasibility of substituting automatic for human-demarcated segmentation of major anatomic structures in clinical lumbar spine MRI to generate quantitative image-based features and biomechanical models. Setting: Previous studies have demonstrated the viability of automatic segmentation applied to medical images; however, the feasibility of these networks to segment clinically acquired images has not yet been demonstrated, as they largely rely on specialized sequences or strict quality of imaging data to achieve good performance. Methods: Convolutional neural networks were trained to demarcate vertebral bodies, intervertebral disc, and paraspinous muscles from sagittal and axial T1-weighted MRIs. Intervertebral disc height, muscle cross-sectional area, and subject-specific musculoskeletal models of tissue loading in the lumbar spine were then computed from these segmentations and compared against those computed from human-demarcated masks. Results: Segmentation masks, as well as the morphological metrics and biomechanical models computed from those masks, were highly similar between human- and computer-generated methods. Segmentations were similar, with Dice similarity coefficients of 0.77 or greater across networks, and morphological metrics and biomechanical models were similar, with Pearson R correlation coefficients of 0.69 or greater when significant. Conclusions: This study demonstrates the feasibility of substituting computer-generated for human-generated segmentations of major anatomic structures in lumbar spine MRI to compute quantitative image-based morphological metrics and subject-specific musculoskeletal models of tissue loading quickly, efficiently, and at scale without interrupting routine clinical care.
- 31 October 2022
- Published by Oxford University Press (OUP) in Pain Medicine
- Vol. 24 (Supplement) , S139-S148
Open AccessDeep Learning for Multi-Tissue Segmentation and Fully Automatic Personalized Biomechanical Models from BACPAC Clinical Lumbar Spine MRI
Study Design: In vivo retrospective study of fully automatic quantitative imaging feature extraction from clinically acquired lumbar spine magnetic resonance imaging (MRI). Objective: To demonstrate the feasibility of substituting automatic for human-demarcated segmentation of major anatomic structures in clinical lumbar spine MRI to generate quantitative image-based features and biomechanical models. Setting: Previous studies have demonstrated the viability of automatic segmentation applied to medical images; however, the feasibility of these networks to segment clinically acquired images has not yet been demonstrated, as they largely rely on specialized sequences or strict quality of imaging data to achieve good performance. Methods: Convolutional neural networks were trained to demarcate vertebral bodies, intervertebral disc, and paraspinous muscles from sagittal and axial T1-weighted MRIs. Intervertebral disc height, muscle cross-sectional area, and subject-specific musculoskeletal models of tissue loading in the lumbar spine were then computed from these segmentations and compared against those computed from human-demarcated masks. Results: Segmentation masks, as well as the morphological metrics and biomechanical models computed from those masks, were highly similar between human- and computer-generated methods. Segmentations were similar, with Dice similarity coefficients of 0.77 or greater across networks, and morphological metrics and biomechanical models were similar, with Pearson R correlation coefficients of 0.69 or greater when significant. Conclusions: This study demonstrates the feasibility of substituting computer-generated for human-generated segmentations of major anatomic structures in lumbar spine MRI to compute quantitative image-based morphological metrics and subject-specific musculoskeletal models of tissue loading quickly, efficiently, and at scale without interrupting routine clinical care.