Theofanis Vrettos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Theofanis Vrettos has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Evangelos Liatsikos
Department of Urology, University of Patras Hospital, Patras, Greece
10 shared publications - Panagiotis Kallidonis
Department of Urology, University Hospital of Patras, Patras, Greece
10 shared publications - Vasileios Tatanis
Department of Urology, University of Patras, Patras, Greece
9 shared publications - Angelis Peteinaris
Department of Urology, University of Patras Hospital, Patras, Greece
8 shared publications - Paraskevi Katsakiori
Department of Urology, University Hospital of Patras, 26504 Patras, Greece
8 shared publications - Theodoros Spinos
Department of Urology, University of Patras Hospital, 26504 Patras, Greece
6 shared publications
Latest Publications
- Open Access
- 6 May 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (9) , 3537
Use of Novel 6.3 Fr Ureteroscope in Endoscopic Combined Intrarenal Surgery (ECIRS): Comparative Experience with Conventional Ureteroscopes
Background/Objectives: Recently, a 6.3 Fr single-use flexible ureteroscope (f-URS) was introduced to the market. The purpose of this pilot study is to present our experience with it during Endoscopic Combined Intrarenal Surgery (ECIRS) and to compare its performance with the conventional 7.5 Fr scope. Methods: For percutaneous access, renal puncture was performed in a nonpapillary approach. Regarding retrograde access, for the first group, a 7.5 Fr single-use f-URS was used, while for the second group, a 6.3 Fr single-use f-URS was utilized. Lithotripsy was primarily performed in an antegrade manner, using the Lithoclast Trilogy®. In cases where stones could not be reached with a nephroscope, retrograde lithotripsy was performed with either a Holmium:YAG laser or a Thulium Fiber Laser. Results: In total, 45 patients were included. Of these, 23 patients underwent ECIRS with the 6.3 Fr f-URS and 22 with the 7.5 Fr f-URS. The mean operative time, fluoroscopy time and lasing time were 59.5 ± 5.6 min, 139.7 ± 14.2 s and 18.4 ± 2.7 min in the 6.3 Fr group and 57.1 ± 3.9 min, 133.8 ± 29.7 s and 18.6 ± 1.9 min in the 7.5 Fr group, respectively. Two patients in the 6.3 Fr group and three patients in the 7.5 Fr group experienced Grade II complications. Stone-free rates were 91.3% in the 6.3 Fr group versus 86.4% in the 7.5 Fr group. Conclusions: The use of a 6.3 Fr f-URS during ECIRS is potentially a feasible, safe and efficient approach. Both the 6.3 Fr and 7.5 Fr scopes were associated with comparable outcomes during ECIRS. Additional studies are needed so as to draw safer conclusions.
- 6 May 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (9) , 3537
Open AccessUse of Novel 6.3 Fr Ureteroscope in Endoscopic Combined Intrarenal Surgery (ECIRS): Comparative Experience with Conventional Ureteroscopes
Background/Objectives: Recently, a 6.3 Fr single-use flexible ureteroscope (f-URS) was introduced to the market. The purpose of this pilot study is to present our experience with it during Endoscopic Combined Intrarenal Surgery (ECIRS) and to compare its performance with the conventional 7.5 Fr scope. Methods: For percutaneous access, renal puncture was performed in a nonpapillary approach. Regarding retrograde access, for the first group, a 7.5 Fr single-use f-URS was used, while for the second group, a 6.3 Fr single-use f-URS was utilized. Lithotripsy was primarily performed in an antegrade manner, using the Lithoclast Trilogy®. In cases where stones could not be reached with a nephroscope, retrograde lithotripsy was performed with either a Holmium:YAG laser or a Thulium Fiber Laser. Results: In total, 45 patients were included. Of these, 23 patients underwent ECIRS with the 6.3 Fr f-URS and 22 with the 7.5 Fr f-URS. The mean operative time, fluoroscopy time and lasing time were 59.5 ± 5.6 min, 139.7 ± 14.2 s and 18.4 ± 2.7 min in the 6.3 Fr group and 57.1 ± 3.9 min, 133.8 ± 29.7 s and 18.6 ± 1.9 min in the 7.5 Fr group, respectively. Two patients in the 6.3 Fr group and three patients in the 7.5 Fr group experienced Grade II complications. Stone-free rates were 91.3% in the 6.3 Fr group versus 86.4% in the 7.5 Fr group. Conclusions: The use of a 6.3 Fr f-URS during ECIRS is potentially a feasible, safe and efficient approach. Both the 6.3 Fr and 7.5 Fr scopes were associated with comparable outcomes during ECIRS. Additional studies are needed so as to draw safer conclusions.
- Open Access
Is a Ureteral Access Sheath Necessary for Maintaining Safe Intrarenal Pressures During Retrograde Lithotripsy Using a Flexible 7.5 Fr Scope and a High-Power TFL? In Vivo Experimental Study
Background and Objectives: To evaluate the effect of a ureteral access sheath (UAS) on the maximal intra-pelvic pressure (IPP max) during retrograde lithotripsy of hard and soft stones in a porcine model. Materials and Methods: A 22 Fr percutaneous tract was established in the upper calyces of the kidneys in three female pigs. A custom-made Foley catheter with a urodynamic catheter was inserted into the pelvicalyceal system and connected to a urodynamic device for real-time IPP measurement. A Pusen Uscope 7.5 Fr single-use ureteroscope (Zhuhai Pusen Medical Technology, Jinhua, China) with manual pump irrigation was used. BegoStone™ powder (Bego, Lincoln, RI, USA) was prepared in two powder-to-water ratios (15:3 and 15:6) to create hard and soft stones, respectively. Stones were positioned in the pelvicalyceal system through the percutaneous tract, and retrograde intrarenal lithotripsy was performed in three settings: without UAS and with a 9.5/11 Fr UAS, with lasing in the center of the pelvis, and during lithotripsy of soft and hard stones. Results: With manual pump irrigation and without a UAS, the IPP max reached 55 cmH2O during lasing in the pelvis center. During lithotripsy of soft and hard stones, the IPP max increased to 62 and 65 cmH2O, respectively. Using a UAS, the IPP max was significantly lower: 18 cmH2O in the center of the pelvis, and 25 and 29 cmH2O during lithotripsy of soft and hard stones, respectively. Conclusions: Manual pump irrigation without a UAS can elevate IPP max to potentially unsafe levels during retrograde correct flexible lithotripsy, even when using a 7.5 Fr flexible scope. The addition of a UAS helps maintain the IPP max within safer limits.
Open AccessIs a Ureteral Access Sheath Necessary for Maintaining Safe Intrarenal Pressures During Retrograde Lithotripsy Using a Flexible 7.5 Fr Scope and a High-Power TFL? In Vivo Experimental Study
Background and Objectives: To evaluate the effect of a ureteral access sheath (UAS) on the maximal intra-pelvic pressure (IPP max) during retrograde lithotripsy of hard and soft stones in a porcine model. Materials and Methods: A 22 Fr percutaneous tract was established in the upper calyces of the kidneys in three female pigs. A custom-made Foley catheter with a urodynamic catheter was inserted into the pelvicalyceal system and connected to a urodynamic device for real-time IPP measurement. A Pusen Uscope 7.5 Fr single-use ureteroscope (Zhuhai Pusen Medical Technology, Jinhua, China) with manual pump irrigation was used. BegoStone™ powder (Bego, Lincoln, RI, USA) was prepared in two powder-to-water ratios (15:3 and 15:6) to create hard and soft stones, respectively. Stones were positioned in the pelvicalyceal system through the percutaneous tract, and retrograde intrarenal lithotripsy was performed in three settings: without UAS and with a 9.5/11 Fr UAS, with lasing in the center of the pelvis, and during lithotripsy of soft and hard stones. Results: With manual pump irrigation and without a UAS, the IPP max reached 55 cmH2O during lasing in the pelvis center. During lithotripsy of soft and hard stones, the IPP max increased to 62 and 65 cmH2O, respectively. Using a UAS, the IPP max was significantly lower: 18 cmH2O in the center of the pelvis, and 25 and 29 cmH2O during lithotripsy of soft and hard stones, respectively. Conclusions: Manual pump irrigation without a UAS can elevate IPP max to potentially unsafe levels during retrograde correct flexible lithotripsy, even when using a 7.5 Fr flexible scope. The addition of a UAS helps maintain the IPP max within safer limits.
- Open Access
- 11 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (22) , 6788
Kidney-Sparing Management of UTUC in Solitary Kidney Patients: A Retrospective Analysis and Narrative Review
Background/Objectives: The aim of this study is the presentation of an endoscopic therapeutic approach for three patients with a solitary kidney who were diagnosed with urothelial cancer of the upper tract. Methods: This retrospective analysis included patients with solitary kidneys who suffered from high-grade UTUC (urothelial cancer of the upper urinary tract) and underwent conservative treatment. Results: The first patient was a 67-year-old male who had a prior history of a nephroureterectomy due to UTUC six years ago. The patient was diagnosed with high-grade UTUC in the contralateral kidney. The tumor has been managed with endoscopic ablation. The second patient was a 74-year-old male with a non-functional kidney and high-grade UTUC diagnosed in the contralateral side. The patient underwent endoscopic ablation for the tumor. The third case was a 68-year-old female patient who had a history of a nephroureterectomy due to UTUC. Afterward, she was diagnosed with high-grade UTUC in the contralateral kidney. The patient was treated with percutaneous tumor resection and the placement of a nephrostomy tube. The first patient was included in an immunotherapy program based on an oncologist consultation after laser ablation treatment for Ta high-grade UTUC, followed by the endoscopic management of two recurrences. Afterward, no recurrence was detected. The remaining two patients followed up without the detection of a new recurrence. Conclusions: The kidney-sparing approach (tumor laser ablation or resection) for high-risk UTUC treatment in selected patients with solitary kidneys seems to provide adequate early outcomes in relation to preserving renal function and effective disease management. It is important to personalize the way of treatment in every case after a thorough examination of the patient’s data.
- 11 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (22) , 6788
Open AccessKidney-Sparing Management of UTUC in Solitary Kidney Patients: A Retrospective Analysis and Narrative Review
Background/Objectives: The aim of this study is the presentation of an endoscopic therapeutic approach for three patients with a solitary kidney who were diagnosed with urothelial cancer of the upper tract. Methods: This retrospective analysis included patients with solitary kidneys who suffered from high-grade UTUC (urothelial cancer of the upper urinary tract) and underwent conservative treatment. Results: The first patient was a 67-year-old male who had a prior history of a nephroureterectomy due to UTUC six years ago. The patient was diagnosed with high-grade UTUC in the contralateral kidney. The tumor has been managed with endoscopic ablation. The second patient was a 74-year-old male with a non-functional kidney and high-grade UTUC diagnosed in the contralateral side. The patient underwent endoscopic ablation for the tumor. The third case was a 68-year-old female patient who had a history of a nephroureterectomy due to UTUC. Afterward, she was diagnosed with high-grade UTUC in the contralateral kidney. The patient was treated with percutaneous tumor resection and the placement of a nephrostomy tube. The first patient was included in an immunotherapy program based on an oncologist consultation after laser ablation treatment for Ta high-grade UTUC, followed by the endoscopic management of two recurrences. Afterward, no recurrence was detected. The remaining two patients followed up without the detection of a new recurrence. Conclusions: The kidney-sparing approach (tumor laser ablation or resection) for high-risk UTUC treatment in selected patients with solitary kidneys seems to provide adequate early outcomes in relation to preserving renal function and effective disease management. It is important to personalize the way of treatment in every case after a thorough examination of the patient’s data.
- Open Access
Anterior and Mid-Penile Hypospadias Repair with TIP Technique—Is It Possible with 20-Hour Catheterization?
Background/Objectives: Several surgical procedures have been proposed for the treatment of hypospadias, a common and heterogeneous congenital abnormality in males. Most surgeons utilize either a urethral stent or bladder catheter for 2–14 days as a postoperative urine diversion method depending on the severity of each case and the surgeon’s preferences. The aim of the present study was to evaluate the feasibility of anterior and mid-penile hypospadias repair while placing the urethral catheter for only 20 h. Methods: A single-centre retrospective study was conducted, including all patients who underwent anterior or penile hypospadias repair from January 2012 to January 2023. All operations were performed based on the Tubularized Incised Plate (TIP) Urethroplasty. At the end of the operation, a 6 Fr 100% silicon catheter was stabilized. The catheter was removed 20 h postoperatively, and all patients were discharged on the first postoperative day. The primary endpoint of the study was the complication rate. Results: In total, 104 patients were enrolled. Eighty (76.9%) patients presented with distal penile hypospadias, while 24 patients (23.1%) had mid-penile hypospadias. The mean age at the operation was 20.8 ± 12.4 months, while the mean operative time was 114.2 ± 28.7 min. All the operations were successfully completed. During the follow-up period (mean duration 101.1 ± 44.8 months), complications were recorded in 16.3% of the patients. Conclusions: The application of 20-h catheterization seems to be an effective alternative with outcomes comparable to other conventional drainage approaches, as it reduces the discomfort of the patients without increased risk of complications.
Open AccessAnterior and Mid-Penile Hypospadias Repair with TIP Technique—Is It Possible with 20-Hour Catheterization?
Background/Objectives: Several surgical procedures have been proposed for the treatment of hypospadias, a common and heterogeneous congenital abnormality in males. Most surgeons utilize either a urethral stent or bladder catheter for 2–14 days as a postoperative urine diversion method depending on the severity of each case and the surgeon’s preferences. The aim of the present study was to evaluate the feasibility of anterior and mid-penile hypospadias repair while placing the urethral catheter for only 20 h. Methods: A single-centre retrospective study was conducted, including all patients who underwent anterior or penile hypospadias repair from January 2012 to January 2023. All operations were performed based on the Tubularized Incised Plate (TIP) Urethroplasty. At the end of the operation, a 6 Fr 100% silicon catheter was stabilized. The catheter was removed 20 h postoperatively, and all patients were discharged on the first postoperative day. The primary endpoint of the study was the complication rate. Results: In total, 104 patients were enrolled. Eighty (76.9%) patients presented with distal penile hypospadias, while 24 patients (23.1%) had mid-penile hypospadias. The mean age at the operation was 20.8 ± 12.4 months, while the mean operative time was 114.2 ± 28.7 min. All the operations were successfully completed. During the follow-up period (mean duration 101.1 ± 44.8 months), complications were recorded in 16.3% of the patients. Conclusions: The application of 20-h catheterization seems to be an effective alternative with outcomes comparable to other conventional drainage approaches, as it reduces the discomfort of the patients without increased risk of complications.
- 1 July 2024
- Published by SAGE Publications in Journal of Endourology
- Vol. 38 (7) , 652-660
Novel Robotic Platforms for Robot-Assisted Laparoscopic Surgery in Urology: A Narrative Review
Robot-assisted surgery (RAS) has been integrated into clinical practice to overcome several limitations of conventional open or laparoscopic surgery. After the expiration of the long key patent period of Intuitive Surgical, various robotic systems (RSs) have been developed aiming at improving certain characteristics of the first robotic platform, the Da Vinci RS. This narrative review provides an overview of the current RSs utilized in urology along with the initial results from their application in urologic procedures. Nine robotic platforms are being analyzed regarding their unique characteristics as well as their efficacy, safety, feasibility, and outcomes in urologic, oncological or non-oncological operations. The main barrier to the wide application of RAS has been the increased cost which refers to both acquisition and maintenance costs. Besides, the health inequality resulting from the lack of expert robotic surgeons and the difficulty of performing robot-assisted procedures in provincial hospitals should be overcome. However, large properly designed comparative studies are required to establish the role of newly introduced RSs. Additionally, urologists should keep abreast of new developments and research in robot-assisted urologic procedures.
- 1 July 2024
- Published by SAGE Publications in Journal of Endourology
- Vol. 38 (7) , 652-660
Novel Robotic Platforms for Robot-Assisted Laparoscopic Surgery in Urology: A Narrative Review
Robot-assisted surgery (RAS) has been integrated into clinical practice to overcome several limitations of conventional open or laparoscopic surgery. After the expiration of the long key patent period of Intuitive Surgical, various robotic systems (RSs) have been developed aiming at improving certain characteristics of the first robotic platform, the Da Vinci RS. This narrative review provides an overview of the current RSs utilized in urology along with the initial results from their application in urologic procedures. Nine robotic platforms are being analyzed regarding their unique characteristics as well as their efficacy, safety, feasibility, and outcomes in urologic, oncological or non-oncological operations. The main barrier to the wide application of RAS has been the increased cost which refers to both acquisition and maintenance costs. Besides, the health inequality resulting from the lack of expert robotic surgeons and the difficulty of performing robot-assisted procedures in provincial hospitals should be overcome. However, large properly designed comparative studies are required to establish the role of newly introduced RSs. Additionally, urologists should keep abreast of new developments and research in robot-assisted urologic procedures.
- Open Access
- 16 February 2024
- Published by PAGEPress Publications in Archivio Italiano di Urologia e Andrologia
- Vol. 96 (1)
Endoscopic enucleation of the prostate with Thulium Fiber Laser (ThuFLEP). A retrospective single-center study
Purpose: The aim of the present, retrospective study was to describe our initial experience and early outcomes of Thulium Fiber Laser enucleation of the prostate (ThuFLEP) with the use of the FiberDust™ (Quanta System, Samarate, Italy) in patients with benign prostate hyperplasia.Methods: From June 2022 to April 2023, all patients who underwent endoscopic enucleation of the prostate at Urology Department of the University Hospital of Patras were included. A single surgeon utilizing the same standardized operative technique performed all the surgeries. The primary endpoints included the uneventful completion of the operation, the surgical time and any minor or major complication observed intra- or post-operatively.Results: Twenty patients with benign prostate hyperplasia were treated with ThuFLEP. All the surgeries were completed successfully and uneventfully. The enucleation phase of the operation was completed in a mean time of 45±9.1 min, while the average time needed for the morcellation was 17.65±3.42 min. No significant complications were observed intra- or post-operatively. The average hemoglobin drop was calculated to be 0.94±0.71 g/dL.Conclusions: All the operations were successfully and efficiently completed with the use of the FiberDust™ (Quanta System, Samarate, Italy) in ThuFLEP. Significant blood loss or major complications were not observed.
- 16 February 2024
- Published by PAGEPress Publications in Archivio Italiano di Urologia e Andrologia
- Vol. 96 (1)
Open AccessEndoscopic enucleation of the prostate with Thulium Fiber Laser (ThuFLEP). A retrospective single-center study
Purpose: The aim of the present, retrospective study was to describe our initial experience and early outcomes of Thulium Fiber Laser enucleation of the prostate (ThuFLEP) with the use of the FiberDust™ (Quanta System, Samarate, Italy) in patients with benign prostate hyperplasia.Methods: From June 2022 to April 2023, all patients who underwent endoscopic enucleation of the prostate at Urology Department of the University Hospital of Patras were included. A single surgeon utilizing the same standardized operative technique performed all the surgeries. The primary endpoints included the uneventful completion of the operation, the surgical time and any minor or major complication observed intra- or post-operatively.Results: Twenty patients with benign prostate hyperplasia were treated with ThuFLEP. All the surgeries were completed successfully and uneventfully. The enucleation phase of the operation was completed in a mean time of 45±9.1 min, while the average time needed for the morcellation was 17.65±3.42 min. No significant complications were observed intra- or post-operatively. The average hemoglobin drop was calculated to be 0.94±0.71 g/dL.Conclusions: All the operations were successfully and efficiently completed with the use of the FiberDust™ (Quanta System, Samarate, Italy) in ThuFLEP. Significant blood loss or major complications were not observed.
- Open Access
- 16 February 2024
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 15, 47
Delayed postoperative erosion of hypopharynx after anterior hardware extrusion: A case report
Postoperative erosion of hypopharynx is a serious and potentially fatal complication of anterior cervical corpectomy/fusion (ACF).
- 16 February 2024
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 15, 47
Open AccessDelayed postoperative erosion of hypopharynx after anterior hardware extrusion: A case report
Postoperative erosion of hypopharynx is a serious and potentially fatal complication of anterior cervical corpectomy/fusion (ACF).
- Open Access
- 22 January 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (2) , 621
Nonpapillary Prone Endoscopic Combined Intrarenal Surgery (ECIRS): Five-Year Experience and Outcomes from a High-Volume Center
Endoscopic combined intrarenal surgery (ECIRS) provides simultaneous retrograde and percutaneous access to the upper urinary tract. The purpose of this study is to present revised data, tips and tricks, and technique modifications arising from our five-year experience with ECIRS. The data of 62 patients who underwent nonpapillary prone ECIRS from January 2019 to November 2023 were prospectively collected. All cases were performed in the prone position. Inclusion criteria were complex stone cases with stones in multiple calyces requiring either multiple accesses or multiple sessions to achieve stone-free status. Patients’ mean age was 54.4 ± 12.39 years, while the mean stone size was 39.03 ± 13.93 mm. The mean operative time was 51.23 ± 17.75 min. Primary and final stone-free rates were 83.8% and 90.3%, respectively. In total, nine patients presented with postoperative complications, which were all Grade II ones. The holmium-YAG laser type during retrograde lithotripsy was associated with significantly shorter operative times compared to the thulium fiber laser. Nonpapillary prone ECIRS is a feasible, safe, and efficient approach for patients with specific stone and anatomy characteristics. The implementation of more, higher-evidence studies is of utmost importance so that safer conclusions can be drawn.
- 22 January 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (2) , 621
Open AccessNonpapillary Prone Endoscopic Combined Intrarenal Surgery (ECIRS): Five-Year Experience and Outcomes from a High-Volume Center
Endoscopic combined intrarenal surgery (ECIRS) provides simultaneous retrograde and percutaneous access to the upper urinary tract. The purpose of this study is to present revised data, tips and tricks, and technique modifications arising from our five-year experience with ECIRS. The data of 62 patients who underwent nonpapillary prone ECIRS from January 2019 to November 2023 were prospectively collected. All cases were performed in the prone position. Inclusion criteria were complex stone cases with stones in multiple calyces requiring either multiple accesses or multiple sessions to achieve stone-free status. Patients’ mean age was 54.4 ± 12.39 years, while the mean stone size was 39.03 ± 13.93 mm. The mean operative time was 51.23 ± 17.75 min. Primary and final stone-free rates were 83.8% and 90.3%, respectively. In total, nine patients presented with postoperative complications, which were all Grade II ones. The holmium-YAG laser type during retrograde lithotripsy was associated with significantly shorter operative times compared to the thulium fiber laser. Nonpapillary prone ECIRS is a feasible, safe, and efficient approach for patients with specific stone and anatomy characteristics. The implementation of more, higher-evidence studies is of utmost importance so that safer conclusions can be drawn.
- Open Access
- 5 December 2023
- Published by PAGEPress Publications in Archivio Italiano di Urologia e Andrologia
- Vol. 95 (4)
Feasibility study of a novel robotic system for transperitoneal partial nephrectomy: An in vivo experimental animal study
Purpose: To evaluate the safety and feasibility of partial nephrectomy with the use of the novel robotic system in an in vivo animal model. Methods: Right partial nephrectomy was performed in female pigs by a surgical team consisting of one surgeon and one bedside assistant. Both were experienced in laparoscopic surgery and trained in the use of the novel robotic system. The partial nephrectomies were performed using four trocars (three trocars for the robotic arms and one as an assistant trocar). The completion of the operations, set-up time, operation time, warm ischemia time (WIT) and complication events were recorded. The decrease in all variables between the first and last operation was calculated. Results: In total, eight partial nephrectomies were performed in eight female pigs. All operations were successfully completed. The median set-up time was 19.5 (range, 15-30) minutes, while the estimated median operative time was 80.5 minutes (range, 59-114). The median WIT was 23.5 minutes (range, 17-32) and intra- or postoperative complications were not observed. All variables decreased in consecutive operations. More precisely, the decrease in the set-up time was calculated to 15 minutes between the first and third attempts. The operative time was reduced by 55 minutes between the first and last operation, while the WIT was decreased by 15 minutes during the consecutive attempts. No complications were noticed in any operation. Conclusions: Using the newly introduced robotic system, all the advantages of robotic surgery are optimized and incorporated, and partial nephrectomies can be performed in a safe and effective manner.
- 5 December 2023
- Published by PAGEPress Publications in Archivio Italiano di Urologia e Andrologia
- Vol. 95 (4)
Open AccessFeasibility study of a novel robotic system for transperitoneal partial nephrectomy: An in vivo experimental animal study
Purpose: To evaluate the safety and feasibility of partial nephrectomy with the use of the novel robotic system in an in vivo animal model. Methods: Right partial nephrectomy was performed in female pigs by a surgical team consisting of one surgeon and one bedside assistant. Both were experienced in laparoscopic surgery and trained in the use of the novel robotic system. The partial nephrectomies were performed using four trocars (three trocars for the robotic arms and one as an assistant trocar). The completion of the operations, set-up time, operation time, warm ischemia time (WIT) and complication events were recorded. The decrease in all variables between the first and last operation was calculated. Results: In total, eight partial nephrectomies were performed in eight female pigs. All operations were successfully completed. The median set-up time was 19.5 (range, 15-30) minutes, while the estimated median operative time was 80.5 minutes (range, 59-114). The median WIT was 23.5 minutes (range, 17-32) and intra- or postoperative complications were not observed. All variables decreased in consecutive operations. More precisely, the decrease in the set-up time was calculated to 15 minutes between the first and third attempts. The operative time was reduced by 55 minutes between the first and last operation, while the WIT was decreased by 15 minutes during the consecutive attempts. No complications were noticed in any operation. Conclusions: Using the newly introduced robotic system, all the advantages of robotic surgery are optimized and incorporated, and partial nephrectomies can be performed in a safe and effective manner.
- Open Access
- 1 January 2023
- Published by AVES YAYINCILIK A.Ş. in Urology Research and Practice
- Vol. 49 (6) , 387-391
How Safe Are the Laparoscopic and Robotic Graspers? Evaluation of the Novel Avatera Robotic Surgical System: An Acute In Vivo Study on a Porcine Model
Objective: To evaluate the tissue injury caused by the force applied by the roboticassisted graspers of avatera robotic surgical system on bowel tissue. Methods: An experimental in vivo porcine model with 1 pig was conducted. After a standard transperitoneal setup of the avatera robotic surgical system, different laparoscopic and robotic graspers were used on the bowel with maximum force applied each time. Robotic atraumatic grasper, laparoscopic right angle grasper, laparoscopic curved grasper, and laparoscopic atraumatic grasper were used. After using all graspers, the pig was sacrificed. The bowel segments were resected and sent for histological analysis. Results: The pathologist reported that all the graspers caused signs of acute inflammation without any irreversible damage or signs compatible with ischemia of the tissue. No significant difference in histology was observed between the graspers. Conclusion: No permanent damage was caused by graspers, except for acute, reversible inflammation. Concluding, the avatera grasper could be safe to use on bowel segments, independent of the applied pressure. Cite this article as: Tatanis V, Natsos A, Tsaturyan A, et al. How safe are the laparoscopic and robotic graspers? Evaluation of the novel avatera robotic surgical system: An acute in vivo study on a porcine model. Urol Res Pract. 2023;49(6):387-391.
- 1 January 2023
- Published by AVES YAYINCILIK A.Ş. in Urology Research and Practice
- Vol. 49 (6) , 387-391
Open AccessHow Safe Are the Laparoscopic and Robotic Graspers? Evaluation of the Novel Avatera Robotic Surgical System: An Acute In Vivo Study on a Porcine Model
Objective: To evaluate the tissue injury caused by the force applied by the roboticassisted graspers of avatera robotic surgical system on bowel tissue. Methods: An experimental in vivo porcine model with 1 pig was conducted. After a standard transperitoneal setup of the avatera robotic surgical system, different laparoscopic and robotic graspers were used on the bowel with maximum force applied each time. Robotic atraumatic grasper, laparoscopic right angle grasper, laparoscopic curved grasper, and laparoscopic atraumatic grasper were used. After using all graspers, the pig was sacrificed. The bowel segments were resected and sent for histological analysis. Results: The pathologist reported that all the graspers caused signs of acute inflammation without any irreversible damage or signs compatible with ischemia of the tissue. No significant difference in histology was observed between the graspers. Conclusion: No permanent damage was caused by graspers, except for acute, reversible inflammation. Concluding, the avatera grasper could be safe to use on bowel segments, independent of the applied pressure. Cite this article as: Tatanis V, Natsos A, Tsaturyan A, et al. How safe are the laparoscopic and robotic graspers? Evaluation of the novel avatera robotic surgical system: An acute in vivo study on a porcine model. Urol Res Pract. 2023;49(6):387-391.