Chao Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chao Chen has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Fangyi Xu
Department of Radiology, Sir Run Run Shaw Hospital, Hangzhou, Zhejiang, China
1 shared publication - Hai-Shan Xu
Ultrasound
1 shared publication - Hongjie Hu
Department of Radiology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, China
1 shared publication - Huitao Wu
Intelligent Healthcare Team, Baidu Inc., Beijing, China
1 shared publication - Jingsong Li
College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou 310027, China
1 shared publication - Lanfen Lin
Zhejiang University
1 shared publication
Latest Publications
- 29 December 2022
- Published by Wolters Kluwer Health in Ultrasound Quarterly
- Vol. 39 (2) , 95-99
Preoperative Value of Contrast-Enhanced Ultrasound in Totally Laparoscopic Associating Liver Partition and Portal Vein Ligation for Staged Hepatectomy for Liver Tumors: A Preliminary Study
The clinical data of 15 cases that planned to receive totally laparoscopic associating liver partition and portal vein ligation for staged hepatectomy were retrospectively collected. Before the stage 1 operation, the size and number of the tumors in future liver remnant (FLR) and the presence of cancer embolus in the portal vein were assessed using contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT). Before the stage 2 operation, CEUS was performed to assess the presence of traffic blood flow between the diseased liver and FLR after round-the-liver ligation. Before the stage 1 operation, 5 cases with tumors in FLR were found by CEUS and 6 cases were found by CECT (P > 0.05). Similarly, CEUS found 5 cases with cancer thrombus in portal vein, and CECT found 7 cases (P = 0.500). The consistency between the 2 modalities was good (κ = 0.857, P < 0.05, κ = 0.727, P < 0.05, respectively). Before the stage 2 operation, CEUS confirmed that there were 7 cases without traffic blood flow between the diseased liver and FLR, and 3 cases with residual traffic blood flow. The daily growth rate of FLR in the group without traffic blood flow (mean rank = 7.00) was higher than that in the group with traffic blood flow (2.00) significantly (P < 0.05). Contrast-enhanced ultrasound is a promising application in the preoperative evaluation of totally laparoscopic associating liver partition and portal vein ligation for staged hepatectomy.
- 29 December 2022
- Published by Wolters Kluwer Health in Ultrasound Quarterly
- Vol. 39 (2) , 95-99
Preoperative Value of Contrast-Enhanced Ultrasound in Totally Laparoscopic Associating Liver Partition and Portal Vein Ligation for Staged Hepatectomy for Liver Tumors: A Preliminary Study
The clinical data of 15 cases that planned to receive totally laparoscopic associating liver partition and portal vein ligation for staged hepatectomy were retrospectively collected. Before the stage 1 operation, the size and number of the tumors in future liver remnant (FLR) and the presence of cancer embolus in the portal vein were assessed using contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT). Before the stage 2 operation, CEUS was performed to assess the presence of traffic blood flow between the diseased liver and FLR after round-the-liver ligation. Before the stage 1 operation, 5 cases with tumors in FLR were found by CEUS and 6 cases were found by CECT (P > 0.05). Similarly, CEUS found 5 cases with cancer thrombus in portal vein, and CECT found 7 cases (P = 0.500). The consistency between the 2 modalities was good (κ = 0.857, P < 0.05, κ = 0.727, P < 0.05, respectively). Before the stage 2 operation, CEUS confirmed that there were 7 cases without traffic blood flow between the diseased liver and FLR, and 3 cases with residual traffic blood flow. The daily growth rate of FLR in the group without traffic blood flow (mean rank = 7.00) was higher than that in the group with traffic blood flow (2.00) significantly (P < 0.05). Contrast-enhanced ultrasound is a promising application in the preoperative evaluation of totally laparoscopic associating liver partition and portal vein ligation for staged hepatectomy.
- 25 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (7) , 2363-2373
Attention-RefNet: Interactive Attention Refinement Network for Infected Area Segmentation of COVID-19
COVID-19 pneumonia is a disease that causes an existential health crisis in many people by directly affecting and damaging lung cells. The segmentation of infected areas from computed tomography (CT) images can be used to assist and provide useful information for COVID-19 diagnosis. Although several deep learning-based segmentation methods have been proposed for COVID-19 segmentation and have achieved state-of-the-art results, the segmentation accuracy is still not high enough (approximately 85%) due to the variations of COVID-19 infected areas (such as shape and size variations) and the similarities between COVID-19 and non-COVID-infected areas. To improve the segmentation accuracy of COVID-19 infected areas, we propose an interactive attention refinement network (Attention RefNet). The interactive attention refinement network can be connected with any segmentation network and trained with the segmentation network in an end-to-end fashion. We propose a skip connection attention module to improve the important features in both segmentation and refinement networks and a seed point module to enhance the important seeds (positions) for interactive refinement. The effectiveness of the proposed method was demonstrated on public datasets (COVID-19CTSeg and MICCAI) and our private multicenter dataset. The segmentation accuracy was improved to more than 90%. We also confirmed the generalizability of the proposed network on our multicenter dataset. The proposed method can still achieve high segmentation accuracy.
- 25 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (7) , 2363-2373
Attention-RefNet: Interactive Attention Refinement Network for Infected Area Segmentation of COVID-19
COVID-19 pneumonia is a disease that causes an existential health crisis in many people by directly affecting and damaging lung cells. The segmentation of infected areas from computed tomography (CT) images can be used to assist and provide useful information for COVID-19 diagnosis. Although several deep learning-based segmentation methods have been proposed for COVID-19 segmentation and have achieved state-of-the-art results, the segmentation accuracy is still not high enough (approximately 85%) due to the variations of COVID-19 infected areas (such as shape and size variations) and the similarities between COVID-19 and non-COVID-infected areas. To improve the segmentation accuracy of COVID-19 infected areas, we propose an interactive attention refinement network (Attention RefNet). The interactive attention refinement network can be connected with any segmentation network and trained with the segmentation network in an end-to-end fashion. We propose a skip connection attention module to improve the important features in both segmentation and refinement networks and a seed point module to enhance the important seeds (positions) for interactive refinement. The effectiveness of the proposed method was demonstrated on public datasets (COVID-19CTSeg and MICCAI) and our private multicenter dataset. The segmentation accuracy was improved to more than 90%. We also confirmed the generalizability of the proposed network on our multicenter dataset. The proposed method can still achieve high segmentation accuracy.