Carolina López Sanguos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Carolina López Sanguos has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Maria Luz Couce
Servicio de Neonatología, Hospital Clínico Universitario de Santiago; IDIS, RICORS-SAMID, Universidad de Santiago de Compostela, Santiago de Compostela (La Coruña), Spain
3 shared publications - Olalla López-Suárez
Department of Neonatology, University Clinical Hospital of Santiago de Compostela, Santiago de Compostela, 15704, Spain; IDIS-Health Research Institute of Santiago de Compostela, Santiago de Compostela, 15704, Spain; Faculty of Medicine, University of Santiago de Compostela, Santiago de Compostela, 15704, Spain; Primary Care Interventions to Prevent Maternal and Child Chronic Diseases of Perinatal and Developmental Origin (RICORS), Instituto de Salud Carlos III, Madrid, Spain
3 shared publications - Elena Martínez-Carballo
Analytical and Food Chemistry Department, Agri-Food Research and Transfer Cluster (CITACA), Campus da Auga, Faculty of Sciences of the University of Vigo, 32004, Ourense, Spain
2 shared publications - Rosaura Picáns-Leis
Servicio de Neonatología, Instituto de Investigación Sanitaria de Santiago (IDIS), Hospital Clínico Universitario de Santiago, Santiago de Compostela, España
2 shared publications - Christer Sinderby
Department of Critical Care, KKeenan Centre for Biomedical Research and Li Ka, Canada
1 shared publication - Elizabeth Asztalos
Women and Babies Program, Division of Neonatology, Department of Pediatrics, Sunnybrook Health Sciences Center, Toronto, ON M4N 3M5, Canada
1 shared publication
Latest Publications
- Open Access
Effect of Nasal Continuous Positive Airway Pressure Delivered by RAM® Cannula Versus Standard Binasal Prongs on Diaphragm Electrical Activity in Very Low Birth Weight Preterm Infants: A Randomized Crossover Trial
Background/Objectives: The RAM cannula is widely used to deliver nasal continuous positive airway pressure (nCPAP) to preterm infants, but its non-occlusive fit permits leak and may reduce the distending pressure transmitted to the airway. Prescribing approximately 2 cmH2O more pressure than with conventional prongs is common but has not been validated physiologically. We compared diaphragm electrical activity (Edi) during nCPAP delivered through a RAM cannula and through Fisher & Paykel (F&P) short binasal prongs. Methods: In a randomized, open-label crossover trial (ClinicalTrials.gov NCT03121781), 20 clinically stable very low birth weight preterm infants on nCPAP received 2 h of nCPAP through each interface in randomized order. Prescribed positive end-expiratory pressure was 2 cmH2O higher during RAM cannula support. Edi was analyzed over the final 15 min of each period. The primary outcome was minimum (end-expiratory) Edi. Within-infant differences (RAM minus F&P) were analyzed with paired t tests. Results: All 20 infants completed both periods, with no missing outcome data. Minimum Edi was higher during RAM cannula support (mean (SD) 3.06 (1.85) versus 2.00 (1.12) microvolts; mean difference 1.06, 95% confidence interval (CI) 0.36 to 1.76; p = 0.005), as were peak Edi (2.02 microvolts, 0.80 to 3.24; p = 0.003) and neural respiratory rate (11.44 breaths/min, 8.07 to 14.82; p < 0.001); each was higher in all 20 infants. Mean fraction of inspired oxygen did not differ significantly (1.56 percentage points, −0.07 to 3.19; p = 0.06). No infant met a prespecified stopping criterion. Conclusions: In clinically stable very low birth weight preterm infants, nCPAP through a RAM cannula was associated with greater diaphragmatic electrical activity and a higher neural respiratory rate than binasal prongs, despite a 2 cmH2O higher prescribed pressure. A fixed 2 cmH2O increment cannot be assumed to restore equivalent support.
Open AccessEffect of Nasal Continuous Positive Airway Pressure Delivered by RAM® Cannula Versus Standard Binasal Prongs on Diaphragm Electrical Activity in Very Low Birth Weight Preterm Infants: A Randomized Crossover Trial
Background/Objectives: The RAM cannula is widely used to deliver nasal continuous positive airway pressure (nCPAP) to preterm infants, but its non-occlusive fit permits leak and may reduce the distending pressure transmitted to the airway. Prescribing approximately 2 cmH2O more pressure than with conventional prongs is common but has not been validated physiologically. We compared diaphragm electrical activity (Edi) during nCPAP delivered through a RAM cannula and through Fisher & Paykel (F&P) short binasal prongs. Methods: In a randomized, open-label crossover trial (ClinicalTrials.gov NCT03121781), 20 clinically stable very low birth weight preterm infants on nCPAP received 2 h of nCPAP through each interface in randomized order. Prescribed positive end-expiratory pressure was 2 cmH2O higher during RAM cannula support. Edi was analyzed over the final 15 min of each period. The primary outcome was minimum (end-expiratory) Edi. Within-infant differences (RAM minus F&P) were analyzed with paired t tests. Results: All 20 infants completed both periods, with no missing outcome data. Minimum Edi was higher during RAM cannula support (mean (SD) 3.06 (1.85) versus 2.00 (1.12) microvolts; mean difference 1.06, 95% confidence interval (CI) 0.36 to 1.76; p = 0.005), as were peak Edi (2.02 microvolts, 0.80 to 3.24; p = 0.003) and neural respiratory rate (11.44 breaths/min, 8.07 to 14.82; p < 0.001); each was higher in all 20 infants. Mean fraction of inspired oxygen did not differ significantly (1.56 percentage points, −0.07 to 3.19; p = 0.06). No infant met a prespecified stopping criterion. Conclusions: In clinically stable very low birth weight preterm infants, nCPAP through a RAM cannula was associated with greater diaphragmatic electrical activity and a higher neural respiratory rate than binasal prongs, despite a 2 cmH2O higher prescribed pressure. A fixed 2 cmH2O increment cannot be assumed to restore equivalent support.
- 14 December 2024
- Published by Elsevier in Clinical Nutrition
- Vol. 44, 178-192
Characterization of the functional component in human milk and identification of the molecular mechanisms undergoing prematurity
- 14 December 2024
- Published by Elsevier in Clinical Nutrition
- Vol. 44, 178-192
Characterization of the functional component in human milk and identification of the molecular mechanisms undergoing prematurity
- Open Access
- 10 October 2023
- Published by Elsevier in Environmental Pollution
- Vol. 339, 122705
Non-invasive biomonitoring of infant exposure to environmental organic pollutants in north-western Spain based on hair analysis. Identification of potential sources
- 10 October 2023
- Published by Elsevier in Environmental Pollution
- Vol. 339, 122705
Open AccessNon-invasive biomonitoring of infant exposure to environmental organic pollutants in north-western Spain based on hair analysis. Identification of potential sources
- Open Access
- 19 December 2022
- Published by Elsevier in Environmental Pollution
- Vol. 318, 120903
Postnatal exposure to organic pollutants in maternal milk in north-western Spain
- 19 December 2022
- Published by Elsevier in Environmental Pollution
- Vol. 318, 120903
Open AccessPostnatal exposure to organic pollutants in maternal milk in north-western Spain