Pedro J. Vidal-Moreno
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pedro J. Vidal-Moreno has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Sonia Martin-Lopez
Universidad de Alcal and the Instituto de ptica Daza de Valds IO-CSIC
5 shared publicationsMiguel Gonzalez-Herraez
University of Alcala,Electronics Department,Alcalá de Henares,Spain
4 shared publications- Hugo Fidalgo Martins
Instituto de ptica Daza de Valds IO-CSIC, Madrid, Spain
3 shared publications Hugo Martins
Daza de Valds Institute of Optics,Madrid,Spain,28006
3 shared publicationsMaría R. Fernández-Ruiz
University of Alcala,Electronics Department,Alcalá de Henares,Spain
3 shared publications- Miguel Gonzalez-Herraez
Universidad de Alcalà
2 shared publications
Latest Publications
- Open Access
- 26 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. PP (07338724) , 1-8
MFDD-CP-$\phi$OTDR Self-Correction for Fiber Calibration in Dynamic Enviroments
Multi-Frequency Database Demodulation (MFDD) combined with chirped-pulse (CP) phase-sensitive OTDR ($\phi$-OTDR) has recently emerged as a promising technique for distributed acoustic sensing (DAS), offering high long-term stability by mitigating $1/f$ noise without compromising sensitivity, and increasing acoustic bandwidth and dynamic range. However, a critical limitation has been the requirement for the fiber to remain unperturbed during the acquisition of the reference matrix, restricting practical deployment in environments with unavoidable ambient vibrations or temperature changes. In this work, we introduce and experimentally validate a self-correcting MFDD method that enables accurate reference matrix calibration under perturbations by treating the MFDD reference acquisition itself as a CP-$\phi$-OTDR measurement. This approach allows perturbations occurring during calibration to be measured and compensated in post-processing, preserving the system's accuracy and stability. We demonstrate the method across three scenarios: (i) a baseline measurement with calibration under quiet conditions, (ii) calibration with intentionally applied perturbations later corrected in post-processing, and (iii) a long-term measurement over 35 hours to assess extended stability. The results show that the self-corrected MFDD approach maintains comparable performance in both fast (100 Hz) dynamic and quas-static measurements. This advancement significantly enhances the robustness of MFDD-CP-$\phi$-OTDR systems, facilitating reliable long-term distributed sensing in practical environments for applications in geophysical monitoring, structural health assessment, and infrastructure surveillance.
- 26 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. PP (07338724) , 1-8
Open AccessMFDD-CP-$\phi$OTDR Self-Correction for Fiber Calibration in Dynamic Enviroments
Multi-Frequency Database Demodulation (MFDD) combined with chirped-pulse (CP) phase-sensitive OTDR ($\phi$-OTDR) has recently emerged as a promising technique for distributed acoustic sensing (DAS), offering high long-term stability by mitigating $1/f$ noise without compromising sensitivity, and increasing acoustic bandwidth and dynamic range. However, a critical limitation has been the requirement for the fiber to remain unperturbed during the acquisition of the reference matrix, restricting practical deployment in environments with unavoidable ambient vibrations or temperature changes. In this work, we introduce and experimentally validate a self-correcting MFDD method that enables accurate reference matrix calibration under perturbations by treating the MFDD reference acquisition itself as a CP-$\phi$-OTDR measurement. This approach allows perturbations occurring during calibration to be measured and compensated in post-processing, preserving the system's accuracy and stability. We demonstrate the method across three scenarios: (i) a baseline measurement with calibration under quiet conditions, (ii) calibration with intentionally applied perturbations later corrected in post-processing, and (iii) a long-term measurement over 35 hours to assess extended stability. The results show that the self-corrected MFDD approach maintains comparable performance in both fast (100 Hz) dynamic and quas-static measurements. This advancement significantly enhances the robustness of MFDD-CP-$\phi$-OTDR systems, facilitating reliable long-term distributed sensing in practical environments for applications in geophysical monitoring, structural health assessment, and infrastructure surveillance.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 19, 27946-27965
Vessel Detection and Localization Using Distributed Acoustic Sensing in Submarine Optical Fiber Cables
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 19, 27946-27965
Open AccessVessel Detection and Localization Using Distributed Acoustic Sensing in Submarine Optical Fiber Cables
- 11 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 43 (10) , 4748-4757
The Use of Genuine Two-Phase Perfect Code for Increased Fiber Sensing Performance
In optical sensing systems, such as fiber-optic sensors and lidar systems, pulse compression is a technique employed to enhance both the temporal/spatial resolution and system sensitivity. These goals are accomplished by transmitting a specific code, and correlating the received echos with a stored version of the code, resulting in a strong and narrow peak, albeit accompanied by sidelobes. Normally, the lower the sidelobes (with respect to the peak) the better the code. Perfect Periodic Autocorrelation (PPA) is a property of certain codes, whose periodic autocorrelation function is identically zero for all out-of-phase shifts. The Legendre code is a popular two-valued PPA code which exhibits the PPA property only when applied with a specific, complex, two-phase alphabet, suggested by S.W. Golomb. Alternatively, the binary version of the Legendre code, although easier to implement, exhibits only a near-perfect periodic autocorrelation with a finite sidelobe level: the longer the code the lower the sidelobe level. This paper investigates, for the first time, the application of complex-valued Legendre PPA codes, comparing their performance to that of a real-valued quasi-PPA one. Configurations studies via both simulation and experiment are dual-path and random multi-path interferometers. In the case of a single reflector, an improvement of 31 dB in Peak to Side-Lobe Ratio (PSLR) is achieved, whereas, for multiple reflectors, involving the cumulative effect of many sidelobes, a 7.5 dB improvement was obtained, solely by using the genuine two-phase values of the Legendre codes instead of their antipodal ($\pm {1}$) version. These observations can benefit code-driven fiber-based sensing systems in sidelobe level limited scenarios.
- 11 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 43 (10) , 4748-4757
The Use of Genuine Two-Phase Perfect Code for Increased Fiber Sensing Performance
In optical sensing systems, such as fiber-optic sensors and lidar systems, pulse compression is a technique employed to enhance both the temporal/spatial resolution and system sensitivity. These goals are accomplished by transmitting a specific code, and correlating the received echos with a stored version of the code, resulting in a strong and narrow peak, albeit accompanied by sidelobes. Normally, the lower the sidelobes (with respect to the peak) the better the code. Perfect Periodic Autocorrelation (PPA) is a property of certain codes, whose periodic autocorrelation function is identically zero for all out-of-phase shifts. The Legendre code is a popular two-valued PPA code which exhibits the PPA property only when applied with a specific, complex, two-phase alphabet, suggested by S.W. Golomb. Alternatively, the binary version of the Legendre code, although easier to implement, exhibits only a near-perfect periodic autocorrelation with a finite sidelobe level: the longer the code the lower the sidelobe level. This paper investigates, for the first time, the application of complex-valued Legendre PPA codes, comparing their performance to that of a real-valued quasi-PPA one. Configurations studies via both simulation and experiment are dual-path and random multi-path interferometers. In the case of a single reflector, an improvement of 31 dB in Peak to Side-Lobe Ratio (PSLR) is achieved, whereas, for multiple reflectors, involving the cumulative effect of many sidelobes, a 7.5 dB improvement was obtained, solely by using the genuine two-phase values of the Legendre codes instead of their antipodal ($\pm {1}$) version. These observations can benefit code-driven fiber-based sensing systems in sidelobe level limited scenarios.
- 23 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Towards Multifrequency Database Demodulation CP-ΦOTDR Field Measurements
Multi-Frequency Database Demodulation (MFDD)- $\text{CP}-\Phi \text{OTDR}$ is a breakthrough in Distributed Acoustic Sensing (DAS) technology that addresses the issue of 1/f reference-update-induced noise, thereby improving low-frequency sensitivity and enabling precise strain or temperature measurements. This innovation is particularly beneficial for expanding seafloor monitoring to cover a wide frequency range, from below 0.01 Hz to several hundred Hz, including infragravity waves and long-period $(>24\mathrm{h})$ oscillations. The MFDD approach necessitates an initial calibration of the fiber, which must remain stable during this phase, a challenging requirement due to environmental dynamics affecting deployed fibers. Calibration time is crucial, with efforts focused on reducing it while maintaining a high Signal-to-Noise Ratio (SNR). Traditional methods rely on trace time-averaging to boost SNR, which unfortunately extends calibration time. This study introduces a novel two-dimensional (2D) filtering technique to eliminate the need for averaging, thereby potentially shortening the calibration period. We explored two types of 2D filters: one based on the Ricker wavelet and another on a sinc-squared function. Our results indicate that the 2D matched filter, particularly the sinc-squared version, offers superior performance in terms of SNR and error reduction, marking a significant advancement in optimizing the calibration process for DAS applications and facilitating more efficient field measurements.- 23 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Towards Multifrequency Database Demodulation CP-ΦOTDR Field Measurements
Multi-Frequency Database Demodulation (MFDD)- $\text{CP}-\Phi \text{OTDR}$ is a breakthrough in Distributed Acoustic Sensing (DAS) technology that addresses the issue of 1/f reference-update-induced noise, thereby improving low-frequency sensitivity and enabling precise strain or temperature measurements. This innovation is particularly beneficial for expanding seafloor monitoring to cover a wide frequency range, from below 0.01 Hz to several hundred Hz, including infragravity waves and long-period $(>24\mathrm{h})$ oscillations. The MFDD approach necessitates an initial calibration of the fiber, which must remain stable during this phase, a challenging requirement due to environmental dynamics affecting deployed fibers. Calibration time is crucial, with efforts focused on reducing it while maintaining a high Signal-to-Noise Ratio (SNR). Traditional methods rely on trace time-averaging to boost SNR, which unfortunately extends calibration time. This study introduces a novel two-dimensional (2D) filtering technique to eliminate the need for averaging, thereby potentially shortening the calibration period. We explored two types of 2D filters: one based on the Ricker wavelet and another on a sinc-squared function. Our results indicate that the 2D matched filter, particularly the sinc-squared version, offers superior performance in terms of SNR and error reduction, marking a significant advancement in optimizing the calibration process for DAS applications and facilitating more efficient field measurements.- Open Access
- 6 May 2024
- Published by Copernicus GmbH
Enhancing earthquake location in deep ocean environments with DAS
Earthquake location schemes for regional oceanic earthquakes within archipelago regionsare limited by the azimuthal resolution that land stations provide for each specific event. Althoughocean bottom seismometers (OBS) can help, they are not suited for real time monitoring and thuscan only provide a posteriori improvements. An alternative approach to improve coverage, notstrictly limited to a temporal increase of onshore stations, is to use Distributed Acoustic Sensing(DAS) on oceanic fiber-optic cables. With DAS, real time monitoring in areas up to 100 kmoffshore is possible, which can potentially improve azimuthal resolution by reaching previouslyinaccessible locations within the archipelago. A great example of such a region are the CanaryIslands, where land-based coverage is already phenomenal yet volcanic activity monitoring fromunderwater sources still has poor coverage in some cases.Recently, the deployment of additional land stations at the islands of Gran Canaria andFuerteventura has revealed existing seismicity between the two islands. When locating the source ofthis seismicity, there is a considerable east-west bias on the azimuthal distribution of those stations.An existing fiber-optic cable that connects the islands of Tenerife and Gran Canaria has beeninterrogated with DAS before, on both sides. The most recent experiment, which was set up on theGran Canaria side, recorded such seismicity from late 2022 to early 2023.This work attempts to use the DAS-recorded onsets of some events for location purposes.First, we test DAS by itself, and subsequently, DAS in combination with land stations. Automatic picking methods are tested for this purpose, since manual picking of onsets is not feasible for DAS. The possibility of catalog revisions using just a few hand-picked onsets atpreviously selected DAS channels is also considered, since there is a lot of redundancy in DAS dataand visual inspection is not unreasonable if limited to a number of channels.
- 6 May 2024
- Published by Copernicus GmbH
Open AccessEnhancing earthquake location in deep ocean environments with DAS
Earthquake location schemes for regional oceanic earthquakes within archipelago regionsare limited by the azimuthal resolution that land stations provide for each specific event. Althoughocean bottom seismometers (OBS) can help, they are not suited for real time monitoring and thuscan only provide a posteriori improvements. An alternative approach to improve coverage, notstrictly limited to a temporal increase of onshore stations, is to use Distributed Acoustic Sensing(DAS) on oceanic fiber-optic cables. With DAS, real time monitoring in areas up to 100 kmoffshore is possible, which can potentially improve azimuthal resolution by reaching previouslyinaccessible locations within the archipelago. A great example of such a region are the CanaryIslands, where land-based coverage is already phenomenal yet volcanic activity monitoring fromunderwater sources still has poor coverage in some cases.Recently, the deployment of additional land stations at the islands of Gran Canaria andFuerteventura has revealed existing seismicity between the two islands. When locating the source ofthis seismicity, there is a considerable east-west bias on the azimuthal distribution of those stations.An existing fiber-optic cable that connects the islands of Tenerife and Gran Canaria has beeninterrogated with DAS before, on both sides. The most recent experiment, which was set up on theGran Canaria side, recorded such seismicity from late 2022 to early 2023.This work attempts to use the DAS-recorded onsets of some events for location purposes.First, we test DAS by itself, and subsequently, DAS in combination with land stations. Automatic picking methods are tested for this purpose, since manual picking of onsets is not feasible for DAS. The possibility of catalog revisions using just a few hand-picked onsets atpreviously selected DAS channels is also considered, since there is a lot of redundancy in DAS dataand visual inspection is not unreasonable if limited to a number of channels.
- 2 August 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (17) , 27450-27461
Noise analysis in direct detection and coherent detection phase-sensitive optical time-domain reflectometry systems
This study compares noise and signal-to-noise ratio (SNR) in direct detection and coherent detection fiber-based distributed acoustic sensing (DAS) systems. Both detection schemes employ the dynamic analysis of Rayleigh-backscattered light in phase-sensitive optical time-domain reflectometry (ΦOTDR) systems. Through theoretical and experimental analysis, it is determined that for photodetection filters with a sufficiently narrow bandwidth, the SNR performance of both detection schemes is comparable. However, for filters with poor selectivity, coherent detection was found to exhibit superior performance. These findings provide crucial guidelines for the design of high-performance time-domain DAS systems.
- 2 August 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (17) , 27450-27461
Noise analysis in direct detection and coherent detection phase-sensitive optical time-domain reflectometry systems
This study compares noise and signal-to-noise ratio (SNR) in direct detection and coherent detection fiber-based distributed acoustic sensing (DAS) systems. Both detection schemes employ the dynamic analysis of Rayleigh-backscattered light in phase-sensitive optical time-domain reflectometry (ΦOTDR) systems. Through theoretical and experimental analysis, it is determined that for photodetection filters with a sufficiently narrow bandwidth, the SNR performance of both detection schemes is comparable. However, for filters with poor selectivity, coherent detection was found to exhibit superior performance. These findings provide crucial guidelines for the design of high-performance time-domain DAS systems.
- 1 January 2023
- Published by Optica Publishing Group
- p. Tu2.5
Frequency-Time 2D Correlation for SNR Improvement in Multifrequency Database Demodulation CP-ΦOTDR
2D correlation enhances SNR of Rayleigh backscattering traces in Multi-Frequency Database Demodulation (MFDD)-CP-ΦOTDR time-frequency maps, avoiding temporal averaging and reducing initial calibration time. This brings the calibrated DAS closer to field measurements.
- 1 January 2023
- Published by Optica Publishing Group
- p. Tu2.5
Frequency-Time 2D Correlation for SNR Improvement in Multifrequency Database Demodulation CP-ΦOTDR
2D correlation enhances SNR of Rayleigh backscattering traces in Multi-Frequency Database Demodulation (MFDD)-CP-ΦOTDR time-frequency maps, avoiding temporal averaging and reducing initial calibration time. This brings the calibrated DAS closer to field measurements.
- 1 January 2023
- Published by Optica Publishing Group
- p. STu3D.4
Ultra-Stable Range-Extended Chirped-Pulse DAS Using Coherent Detection
We present a coherent multifrequency demodulation CP-ΦOTDR system that allows the use of wide filters in detection instead of narrow and tunable filters. Additionally, this opens the door to the use of linear decoding techniques.
- 1 January 2023
- Published by Optica Publishing Group
- p. STu3D.4
Ultra-Stable Range-Extended Chirped-Pulse DAS Using Coherent Detection
We present a coherent multifrequency demodulation CP-ΦOTDR system that allows the use of wide filters in detection instead of narrow and tunable filters. Additionally, this opens the door to the use of linear decoding techniques.