Guixin Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Guixin Sun has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Chensong Yang
Department of Traumatic Surgery, School of Medicine, Shanghai East Hospital, Tongji University, Shanghai, China
7 shared publicationsYue Zhang
Department of Traumatic Surgery, Shanghai East Hospital, School of Medicine, Tongji University, Shanghai, People’s Republic of China
4 shared publicationsChangqing Ai
Department of Traumatic Surgery, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China
3 shared publicationsDi Zhou
Department of Radiology, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China
3 shared publicationsQin Shao
Department of Traumatic Surgery, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China
3 shared publicationsYang Yu
Walkman biomaterial CO., LTD, Tianjin, China
3 shared publications
Latest Publications
- Open Access
- 12 December 2022
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 23 (1) , 1-9
The prognostic value of retinol binding protein in geriatric hip fractures after surgeries: A propensity score matching and 1-year follow-up study
We aimed to explore the predictive value of retinol binding protein (RBP) for outcomes of hip fractures. Patients with hip fractures who underwent hip surgeries between December 2017 and February 2021 and met the inclusion criteria were analyzed. Propensity score matching was used to reduce the bias of co-factors and ROC curves based on matched populations were created to determine the optimal cutoff point of RBP. The outcomes between patients with low levels of RBP and high levels of RBP were compared. Four hundred eighty patients were enrolled in this study and 69 patients died within one year. After a 1:1 PSM, patients with more than 1-year survival had significantly higher RBP (p = 0.013) than those who died within one year, as well as patients divided by 6-months survival (p = 0.012). Logistics analysis showed that low RBP may be an independent risk factor for 3-month survival, 6-month survival, 1-year survival, and 3-month free walking ability. RBP may be associated with the survival and 3-month walking abilities of patients with hip fractures.
- 12 December 2022
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 23 (1) , 1-9
Open AccessThe prognostic value of retinol binding protein in geriatric hip fractures after surgeries: A propensity score matching and 1-year follow-up study
We aimed to explore the predictive value of retinol binding protein (RBP) for outcomes of hip fractures. Patients with hip fractures who underwent hip surgeries between December 2017 and February 2021 and met the inclusion criteria were analyzed. Propensity score matching was used to reduce the bias of co-factors and ROC curves based on matched populations were created to determine the optimal cutoff point of RBP. The outcomes between patients with low levels of RBP and high levels of RBP were compared. Four hundred eighty patients were enrolled in this study and 69 patients died within one year. After a 1:1 PSM, patients with more than 1-year survival had significantly higher RBP (p = 0.013) than those who died within one year, as well as patients divided by 6-months survival (p = 0.012). Logistics analysis showed that low RBP may be an independent risk factor for 3-month survival, 6-month survival, 1-year survival, and 3-month free walking ability. RBP may be associated with the survival and 3-month walking abilities of patients with hip fractures.
- Open Access
- 18 July 2022
- Published by Wiley in Stem Cells International
- Vol. 2022, 1-16
Cebpb Regulates Skeletal Stem Cell Osteogenic Differentiation and Fracture Healing via the WNT/β-Catenin Pathway
Fracture is the most common traumatic organ injury, and fracture nonunion is a critical clinical challenge. The research on the mechanisms of skeletal stem cell (SSC) differentiation and fracture healing may help develop new treatment strategies and improve the prognosis of patients at high risk of nonunion. Bioinformatic analysis of scRNA-seq data of mouse SSCs and mouse osteoprogenitors was applied to discover major transcription factors for the regulation of SSC differentiation. FACS was used to isolate SSCs prospectively. The expression of Cebpb, osteogenesis-related genes (Runx2, Sp7, and Bglap2), and markers for Notch, Hedgehog, MAPK, BMP2/SMAD, and WNT/β-catenin signaling pathways (Hes1, Gli1, p-Erk1/2, p-Smad1/5/9, and β-catenin) were detected in SSCs with qPCR or western blot, respectively. Alkaline phosphatase assay and alizarin red S staining were used to illustrate the osteogenic differentiation ability of SSCs in vitro. A WNT inhibitor, IWR-1, was further used to explore the mechanism of WNT signaling in the differentiation of SSCs. Micro-CT, mechanical testing, and immunohistochemistry of osteogenic and chondrogenic proteins (Sp7 and Col2α1) were used to demonstrate the capacity of Cebpb knockdown in promoting fracture healing in a monocortical defect model. We found that Cebpb was the crucial transcription factor regulating SSC differentiation. Inhibiting Cebpb in SSCs enhanced the expression of active β-catenin to promote the expression of WNT target genes, thus facilitating the osteogenic differentiation of SSCs. Bone mass, mechanical properties, and osteogenic protein expression were also increased in the Cebpb inhibition group compared to the group without Cebpb inhibition. Collectively, our results proved that Cebpb knockdown promotes SSC osteogenic differentiation and fracture healing via the WNT/β-catenin signaling pathway.
- 18 July 2022
- Published by Wiley in Stem Cells International
- Vol. 2022, 1-16
Open AccessCebpb Regulates Skeletal Stem Cell Osteogenic Differentiation and Fracture Healing via the WNT/β-Catenin Pathway
Fracture is the most common traumatic organ injury, and fracture nonunion is a critical clinical challenge. The research on the mechanisms of skeletal stem cell (SSC) differentiation and fracture healing may help develop new treatment strategies and improve the prognosis of patients at high risk of nonunion. Bioinformatic analysis of scRNA-seq data of mouse SSCs and mouse osteoprogenitors was applied to discover major transcription factors for the regulation of SSC differentiation. FACS was used to isolate SSCs prospectively. The expression of Cebpb, osteogenesis-related genes (Runx2, Sp7, and Bglap2), and markers for Notch, Hedgehog, MAPK, BMP2/SMAD, and WNT/β-catenin signaling pathways (Hes1, Gli1, p-Erk1/2, p-Smad1/5/9, and β-catenin) were detected in SSCs with qPCR or western blot, respectively. Alkaline phosphatase assay and alizarin red S staining were used to illustrate the osteogenic differentiation ability of SSCs in vitro. A WNT inhibitor, IWR-1, was further used to explore the mechanism of WNT signaling in the differentiation of SSCs. Micro-CT, mechanical testing, and immunohistochemistry of osteogenic and chondrogenic proteins (Sp7 and Col2α1) were used to demonstrate the capacity of Cebpb knockdown in promoting fracture healing in a monocortical defect model. We found that Cebpb was the crucial transcription factor regulating SSC differentiation. Inhibiting Cebpb in SSCs enhanced the expression of active β-catenin to promote the expression of WNT target genes, thus facilitating the osteogenic differentiation of SSCs. Bone mass, mechanical properties, and osteogenic protein expression were also increased in the Cebpb inhibition group compared to the group without Cebpb inhibition. Collectively, our results proved that Cebpb knockdown promotes SSC osteogenic differentiation and fracture healing via the WNT/β-catenin signaling pathway.
- Open Access
- 1 July 2022
- Published by Taylor & Francis in Clinical Interventions in Aging
- Vol. ume 17, 1081-1090
Superoxide Dismutase and Glutathione Reductase as Indicators of Oxidative Stress Levels May Relate to Geriatric Hip Fractures’ Survival and Walking Ability: A Propensity Score Matching Study
Background: Oxidative stress status may affect bone metabolism and regeneration. However, few studies reported whether oxidative stress could impact the outcomes of hip fractures. This study aimed to explore if superoxide dismutase and glutathione reductase, the critical antioxidant enzymes, correlated with the prognosis of hip fractures. Methods: Patients with hip fractures were extracted from our database, and those who met the inclusion criteria were analyzed. Propensity score matching was used to reduce the influence of confounding factors, and ROC curves based on matched populations were created to determine the optimal cutoff points of SOD and GR. Then, outcomes between SOD or GR and outcomes of hip fractures were compared. Results: Out of 301 patients enrolled in this study, 50 patients died within one year. After a 1:1 PSM, the patients with less than 1-year survival had significantly lower SOD (p = 0.026) and GR (p = 0.021) than those who were still alive at one year. Logistics analysis showed that low SOD and low GR may be independent risk factors for 6-month survival, 1-year survival, 6-month free walking ability, and 1-year free walking ability. Conclusion: SOD and GR may be the independent risk factors for survival and walking abilities of hip fractures.
- 1 July 2022
- Published by Taylor & Francis in Clinical Interventions in Aging
- Vol. ume 17, 1081-1090
Open AccessSuperoxide Dismutase and Glutathione Reductase as Indicators of Oxidative Stress Levels May Relate to Geriatric Hip Fractures’ Survival and Walking Ability: A Propensity Score Matching Study
Background: Oxidative stress status may affect bone metabolism and regeneration. However, few studies reported whether oxidative stress could impact the outcomes of hip fractures. This study aimed to explore if superoxide dismutase and glutathione reductase, the critical antioxidant enzymes, correlated with the prognosis of hip fractures. Methods: Patients with hip fractures were extracted from our database, and those who met the inclusion criteria were analyzed. Propensity score matching was used to reduce the influence of confounding factors, and ROC curves based on matched populations were created to determine the optimal cutoff points of SOD and GR. Then, outcomes between SOD or GR and outcomes of hip fractures were compared. Results: Out of 301 patients enrolled in this study, 50 patients died within one year. After a 1:1 PSM, the patients with less than 1-year survival had significantly lower SOD (p = 0.026) and GR (p = 0.021) than those who were still alive at one year. Logistics analysis showed that low SOD and low GR may be independent risk factors for 6-month survival, 1-year survival, 6-month free walking ability, and 1-year free walking ability. Conclusion: SOD and GR may be the independent risk factors for survival and walking abilities of hip fractures.
- Open Access
- 18 March 2021
- Published by Wiley in Journal of Cellular and Molecular Medicine
- Vol. 25 (10) , 4709-4720
S100A9 induces nucleus pulposus cell degeneration through activation of the NF‐κB signaling pathway
Oxidative stress in the lumbar disc leads to the degeneration of nucleus pulposus (NP). However, the molecular mechanisms underlying this process remain unclear. In this study, we delineated a key calcium‐binding protein, S100A9, which was induced by oxidative stress and was highly expressed in the degenerative NP. Immunofluorescence staining and Western blotting revealed that S100A9 induced NP cell apoptosis in vitro by up‐regulating the expression of pro‐apoptotic markers, including cleaved caspase‐3, cytochrome c and Bax. Moreover, RT‐PCR analyses revealed that the expression of S100A9 caused NP matrix degradation by up‐regulating the expression of matrix degradation enzymes and increased the inflammatory response by up‐regulating cytokine expression. Therefore, S100A9 induced NP cell degeneration by exerting pro‐apoptotic, pro‐degradation and pro‐inflammatory effects. The detailed mechanism underlying S100A9‐induced NP degeneration was explored by administering SC75741, a specific NF‐κB inhibitor in vitro. We concluded that S100A9 induced NP cell apoptosis, caused matrix degradation and amplified the inflammatory response through the activation of the NF‐κB signalling pathway. Inhibition of these pro‐apoptotic, pro‐degradation and pro‐inflammatory effects induced by S100A9 in NP may be a favourable therapeutic strategy to slow lumbar disc degeneration.
- 18 March 2021
- Published by Wiley in Journal of Cellular and Molecular Medicine
- Vol. 25 (10) , 4709-4720
Open AccessS100A9 induces nucleus pulposus cell degeneration through activation of the NF‐κB signaling pathway
Oxidative stress in the lumbar disc leads to the degeneration of nucleus pulposus (NP). However, the molecular mechanisms underlying this process remain unclear. In this study, we delineated a key calcium‐binding protein, S100A9, which was induced by oxidative stress and was highly expressed in the degenerative NP. Immunofluorescence staining and Western blotting revealed that S100A9 induced NP cell apoptosis in vitro by up‐regulating the expression of pro‐apoptotic markers, including cleaved caspase‐3, cytochrome c and Bax. Moreover, RT‐PCR analyses revealed that the expression of S100A9 caused NP matrix degradation by up‐regulating the expression of matrix degradation enzymes and increased the inflammatory response by up‐regulating cytokine expression. Therefore, S100A9 induced NP cell degeneration by exerting pro‐apoptotic, pro‐degradation and pro‐inflammatory effects. The detailed mechanism underlying S100A9‐induced NP degeneration was explored by administering SC75741, a specific NF‐κB inhibitor in vitro. We concluded that S100A9 induced NP cell apoptosis, caused matrix degradation and amplified the inflammatory response through the activation of the NF‐κB signalling pathway. Inhibition of these pro‐apoptotic, pro‐degradation and pro‐inflammatory effects induced by S100A9 in NP may be a favourable therapeutic strategy to slow lumbar disc degeneration.
- Open Access
- 15 March 2021
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 16 (1) , 1-13
Finite element analysis of different locking plate fixation methods for the treatment of ulnar head fracture
Background: Ulnar head fractures are increasingly higher with the growing proportion of the elderly people. Failure to achieve a stable anatomic reduction of ulna head fracture may lead to a distal radioulnar joint (DRUJ) dysfunction and nonunion of the distal radius. Due to the lack of the postoperative reporting outcomes and the biomechanical studies, it has not been well established about the optimal management of the comminuted distal ulna head fracture. Hence, the purpose of this study is to use finite element analysis to explain the advantages and disadvantages of ulnar-side locking plate fixation compared with dorsal-side locking plate fixation and its screw arrangement in the treatment of ulnar head fractures.Methods: FE models of the ulnar head fracture and the models of ulnar-side locking plate and dorsal-side plate with two or three distal screws was constructed. In order to simulate forces acting on the ulnar and the osteosynthesis material during daily-life activity in subjects who underwent reconstructive surgery, we applied three loading conditions to each model, viz. 20 N axial compression, 50 N axial compression, 1 N∙m torsion moment, 1 N∙m lateral bending moments, and 1 N∙m extension bending moments. Under these conditions, values of the von Mises stress (VMS) distribution of the implant, peak VMS, the relative displacement of the head and shaft fragments between the fracture ends and the displacement and its direction of the models were investigated.Results: The stress values of ulnar-side plates were lower than those of dorsal-side plates. And the ulnar-plate fixation system also has smaller maximum displacement and relative displacement. When adding a screw in the middle hole of the ulnar head, the values of model displacement and the peak stress in fixation system are lower, but it may evidently concentrate the stress on the middle screw.Conclusions: In conclusion, our study indicated that ulnar-side locking plates resulted in a lower stress distribution in the plate and better stability than dorsal-side locking plates for ulnar head fracture fixation. Adding an additional screw to the ulnar head could increase the stability of the fixation system and provide an anti-torsion function. This study requires clinical confirmation of its practicality in the treatment of ulnar head fractures. This study requires clinical confirmation as to its practicality in the treatment of ulnar head fracture.
- 15 March 2021
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 16 (1) , 1-13
Open AccessFinite element analysis of different locking plate fixation methods for the treatment of ulnar head fracture
Background: Ulnar head fractures are increasingly higher with the growing proportion of the elderly people. Failure to achieve a stable anatomic reduction of ulna head fracture may lead to a distal radioulnar joint (DRUJ) dysfunction and nonunion of the distal radius. Due to the lack of the postoperative reporting outcomes and the biomechanical studies, it has not been well established about the optimal management of the comminuted distal ulna head fracture. Hence, the purpose of this study is to use finite element analysis to explain the advantages and disadvantages of ulnar-side locking plate fixation compared with dorsal-side locking plate fixation and its screw arrangement in the treatment of ulnar head fractures.Methods: FE models of the ulnar head fracture and the models of ulnar-side locking plate and dorsal-side plate with two or three distal screws was constructed. In order to simulate forces acting on the ulnar and the osteosynthesis material during daily-life activity in subjects who underwent reconstructive surgery, we applied three loading conditions to each model, viz. 20 N axial compression, 50 N axial compression, 1 N∙m torsion moment, 1 N∙m lateral bending moments, and 1 N∙m extension bending moments. Under these conditions, values of the von Mises stress (VMS) distribution of the implant, peak VMS, the relative displacement of the head and shaft fragments between the fracture ends and the displacement and its direction of the models were investigated.Results: The stress values of ulnar-side plates were lower than those of dorsal-side plates. And the ulnar-plate fixation system also has smaller maximum displacement and relative displacement. When adding a screw in the middle hole of the ulnar head, the values of model displacement and the peak stress in fixation system are lower, but it may evidently concentrate the stress on the middle screw.Conclusions: In conclusion, our study indicated that ulnar-side locking plates resulted in a lower stress distribution in the plate and better stability than dorsal-side locking plates for ulnar head fracture fixation. Adding an additional screw to the ulnar head could increase the stability of the fixation system and provide an anti-torsion function. This study requires clinical confirmation of its practicality in the treatment of ulnar head fractures. This study requires clinical confirmation as to its practicality in the treatment of ulnar head fracture.
- Open Access
- 26 January 2021
- Published by Springer Nature in Research Square
Finite element analysis of different locking-plate fixation methods for the treatment of ulnar head fracture
Background: Ulnar head fractures are increasingly higher with the growing proportion of the elderly people. Failure to achieve a stable anatomic reduction of ulna head fracture may lead to a distal radioulnar joint (DRUJ) dysfunction and nonunion of the distal radius. Due to the lack of the postoperative reporting outcomes and the biomechanical studies, it has not been well established about the optimal management of the comminuted distal ulna head fracture. Hence, the purpose of this study is to use finite element analysis to explain the advantages and disadvantages of ulnar-side locking plate fixation compared with dorsal-side locking plate fixation and its screw arrangement in the treatment of ulnar head fractures.Methods: FE models of the ulnar head fracture and the models of ulnar-side locking plate and dorsal-side plate with two or three distal screws was constructed. In order to simulate forces acting on the ulnar and the osteosynthesis material during daily-life activity in subjects who underwent reconstructive surgery, we applied three loading conditions to each model, viz. 20 N axial compression, 50 N axial compression, 1 N∙m torsion moment, 1 N∙m lateral bending moments, and 1 N∙m extension bending moments. Under these conditions, values of the von Mises stress (VMS) distribution of the implant, peak VMS, the relative displacement of the head and shaft fragments between the fracture ends and the displacement and its direction of the models were investigated. Results: The stress values of ulnar-side plates were lower than those of dorsal-side plates. And the ulnar-plate fixation system also has smaller maximum displacement and relative displacement. When adding a screw in the middle hole of the ulnar head, the values of model displacement and the peak stress in fixation system are lower, but it may evidently concentrate the stress on the middle screw. Conclusions: In conclusion, our study indicated that ulnar-side locking plates resulted in a lower stress distribution in the plate and better stability than dorsal-side locking plates for ulnar head fracture fixation. Adding an additional screw to the ulnar head could increase the stability of the fixation system and provide an anti-torsion function. This study requires clinical confirmation of its practicality in the treatment of ulnar head fractures. This study requires clinical confirmation as to its practicality in the treatment of ulnar head fracture.
- 26 January 2021
- Published by Springer Nature in Research Square
Open AccessFinite element analysis of different locking-plate fixation methods for the treatment of ulnar head fracture
Background: Ulnar head fractures are increasingly higher with the growing proportion of the elderly people. Failure to achieve a stable anatomic reduction of ulna head fracture may lead to a distal radioulnar joint (DRUJ) dysfunction and nonunion of the distal radius. Due to the lack of the postoperative reporting outcomes and the biomechanical studies, it has not been well established about the optimal management of the comminuted distal ulna head fracture. Hence, the purpose of this study is to use finite element analysis to explain the advantages and disadvantages of ulnar-side locking plate fixation compared with dorsal-side locking plate fixation and its screw arrangement in the treatment of ulnar head fractures.Methods: FE models of the ulnar head fracture and the models of ulnar-side locking plate and dorsal-side plate with two or three distal screws was constructed. In order to simulate forces acting on the ulnar and the osteosynthesis material during daily-life activity in subjects who underwent reconstructive surgery, we applied three loading conditions to each model, viz. 20 N axial compression, 50 N axial compression, 1 N∙m torsion moment, 1 N∙m lateral bending moments, and 1 N∙m extension bending moments. Under these conditions, values of the von Mises stress (VMS) distribution of the implant, peak VMS, the relative displacement of the head and shaft fragments between the fracture ends and the displacement and its direction of the models were investigated. Results: The stress values of ulnar-side plates were lower than those of dorsal-side plates. And the ulnar-plate fixation system also has smaller maximum displacement and relative displacement. When adding a screw in the middle hole of the ulnar head, the values of model displacement and the peak stress in fixation system are lower, but it may evidently concentrate the stress on the middle screw. Conclusions: In conclusion, our study indicated that ulnar-side locking plates resulted in a lower stress distribution in the plate and better stability than dorsal-side locking plates for ulnar head fracture fixation. Adding an additional screw to the ulnar head could increase the stability of the fixation system and provide an anti-torsion function. This study requires clinical confirmation of its practicality in the treatment of ulnar head fractures. This study requires clinical confirmation as to its practicality in the treatment of ulnar head fracture.
- Open Access
- 3 November 2020
- Published by Springer Nature in Research Square
Finite Element Analysis of Different Locking-Plate Fixation Methods for the Treatment of Ulna Head Fracture
Background: Ulnar head fractures are increasingly higher with the growing proportion of the elderly in the population. Failure to achieve stable anatomic reduction of ulna head fracture may lead to the DRUJ dysfunction and nonunion of distal radius. Due to the lack of the postoperative reporting outcomes and the biomechanical studies, it has not been well established about the optimal management of the comminuted distal ulna head fracture. This study aimed to explain the advantages and disadvantages of the ulnar-side locking plate fixation, compared with the dorsal-side one, and its screws arrangement in the treatment of the ulnar head fracture by using finite element analysis. Methods: FE models of the ulnar head fracture and the models of ulnar-side locking plate and dorsal-side plate with two or three distal screws was constructed. In order to simulate forces acting on the ulnar and the osteosynthesis material during daily-life activity in subjects who underwent reconstructive surgery, we applied three loading conditions to each model, viz. axial compression 20N, 50N, and torsion moments 1Nm. Under these conditions, values of the von Mises Stress (VMS) distribution of the implant, peak VMS, and model displacement were investigated. Results: Both the stress values and model displacement of ulnar-side plate were lower than those of dorsal-side plate. When adding a screw in the middle hole of the ulnar head, the values of model displacement and the peak stress in fixation system are lower, but it may evidently concentrate the stress on the middle screw. Conclusions: In conclusion, our study indicated that plating locking plate on ulnar side had lower stress distribution on the plate and better stability than on dorsal side in ulnar head fracture fixation. Adding the additional screw on the ulnar head could reduce the displacement of the fixation system and increase the stability of the fixation system. This study requires clinical confirmation as to its practicality in the treatment of ulnar head fracture.
- 3 November 2020
- Published by Springer Nature in Research Square
Open AccessFinite Element Analysis of Different Locking-Plate Fixation Methods for the Treatment of Ulna Head Fracture
Background: Ulnar head fractures are increasingly higher with the growing proportion of the elderly in the population. Failure to achieve stable anatomic reduction of ulna head fracture may lead to the DRUJ dysfunction and nonunion of distal radius. Due to the lack of the postoperative reporting outcomes and the biomechanical studies, it has not been well established about the optimal management of the comminuted distal ulna head fracture. This study aimed to explain the advantages and disadvantages of the ulnar-side locking plate fixation, compared with the dorsal-side one, and its screws arrangement in the treatment of the ulnar head fracture by using finite element analysis. Methods: FE models of the ulnar head fracture and the models of ulnar-side locking plate and dorsal-side plate with two or three distal screws was constructed. In order to simulate forces acting on the ulnar and the osteosynthesis material during daily-life activity in subjects who underwent reconstructive surgery, we applied three loading conditions to each model, viz. axial compression 20N, 50N, and torsion moments 1Nm. Under these conditions, values of the von Mises Stress (VMS) distribution of the implant, peak VMS, and model displacement were investigated. Results: Both the stress values and model displacement of ulnar-side plate were lower than those of dorsal-side plate. When adding a screw in the middle hole of the ulnar head, the values of model displacement and the peak stress in fixation system are lower, but it may evidently concentrate the stress on the middle screw. Conclusions: In conclusion, our study indicated that plating locking plate on ulnar side had lower stress distribution on the plate and better stability than on dorsal side in ulnar head fracture fixation. Adding the additional screw on the ulnar head could reduce the displacement of the fixation system and increase the stability of the fixation system. This study requires clinical confirmation as to its practicality in the treatment of ulnar head fracture.
- 1 March 2016
- Vol. 45 (2) , 147-151
诱导多能干细胞治疗失神经性肌肉萎缩的研究进展
诱导多能干细胞(iPSC)是一种类似于胚胎干细胞具有多向分化潜能的组织干细胞,又有胚胎干细胞不可比拟的优势。iPSC移植到受损区域后,经病损部位神经源信号的引导,可分泌修复损伤必需的营养因子,帮助无髓或新生轴突形成髓鞘,为轴突生长提供基质等物质,参与神经立体空间结构的重建,恢复神经系统功能,对周围神经的再生具有非常重要的意义。因此,应用iPSC治疗延缓失神经性肌肉萎缩成为一种可能。
- 1 March 2016
- Vol. 45 (2) , 147-151
诱导多能干细胞治疗失神经性肌肉萎缩的研究进展
诱导多能干细胞(iPSC)是一种类似于胚胎干细胞具有多向分化潜能的组织干细胞,又有胚胎干细胞不可比拟的优势。iPSC移植到受损区域后,经病损部位神经源信号的引导,可分泌修复损伤必需的营养因子,帮助无髓或新生轴突形成髓鞘,为轴突生长提供基质等物质,参与神经立体空间结构的重建,恢复神经系统功能,对周围神经的再生具有非常重要的意义。因此,应用iPSC治疗延缓失神经性肌肉萎缩成为一种可能。
- Open Access
- 1 January 2014
- Published by Medknow in Neural Regeneration Research
- Vol. 9 (23) , 2111-4
Nerve transfer helps repair brachial plexus injury by increasing cerebral cortical plasticity
In the treatment of brachial plexus injury, nerves that are functionally less important are transferred onto the distal ends of damaged crucial nerves to help recover neuromuscular function in the target region. For example, intercostal nerves are transferred onto axillary nerves, and accessory nerves are transferred onto suprascapular nerves, the phrenic nerve is transferred onto the musculocutaneous nerves, and the contralateral C7 nerve is transferred onto the median or radial nerves. Nerve transfer has become a major method for reconstructing the brachial plexus after avulsion injury. Many experiments have shown that nerve transfers for treatment of brachial plexus injury can help reconstruct cerebral cortical function and increase cortical plasticity. In this review article, we summarize the recent progress in the use of diverse nerve transfer methods for the repair of brachial plexus injury, and we discuss the impact of nerve transfer on cerebral cortical plasticity after brachial plexus injury.
- 1 January 2014
- Published by Medknow in Neural Regeneration Research
- Vol. 9 (23) , 2111-4
Open AccessNerve transfer helps repair brachial plexus injury by increasing cerebral cortical plasticity
In the treatment of brachial plexus injury, nerves that are functionally less important are transferred onto the distal ends of damaged crucial nerves to help recover neuromuscular function in the target region. For example, intercostal nerves are transferred onto axillary nerves, and accessory nerves are transferred onto suprascapular nerves, the phrenic nerve is transferred onto the musculocutaneous nerves, and the contralateral C7 nerve is transferred onto the median or radial nerves. Nerve transfer has become a major method for reconstructing the brachial plexus after avulsion injury. Many experiments have shown that nerve transfers for treatment of brachial plexus injury can help reconstruct cerebral cortical function and increase cortical plasticity. In this review article, we summarize the recent progress in the use of diverse nerve transfer methods for the repair of brachial plexus injury, and we discuss the impact of nerve transfer on cerebral cortical plasticity after brachial plexus injury.