Jung Gi Choi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jung Gi Choi has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Seon Jeong Kim
Hanyang University
2 shared publications - Changsoon Choi
Department of Electronic Engineering and Biomedical Engineering Hanyang University Seoul 04763 South Korea
1 shared publication - Christopher J. Richards
ARC Centre of Excellence for Electromaterials Science, Australian Institute for Innovative Materials, University of Wollongong, Wollongong, NSW 2522, Australia
1 shared publication - Duri Han
Department of Electronic Engineering and Biomedical Engineering, Hanyang University, Seoul 04763, Republic of Korea
1 shared publication - Geoffrey M. Spinks
University of Wollongong
1 shared publication - Gyu Hyeon Song
Department of Electronic Engineering and Biomedical Engineering, Hanyang University, Seoul 04763, Republic of Korea
1 shared publication
Latest Publications
- Open Access
Shape-Controlled Poly(N-isopropylacrylamide) Actuators Enabled by Tensile-Stress Mismatch for Temperature-Adaptive Textiles
Thermal comfort is a key determinant of human health and requires adaptive responses to dynamic environments. Here, we report a temperature-adaptive textile enabled by a tensile stress mismatch-driven poly(N-isopropylacrylamide) (PNIPAM) actuator operating within a human-friendly temperature range of 18–38 °C. A pre-stretched polyurethane core fiber integrated within a PNIPAM sheath in a noncoaxial configuration induces programmable bending through tensile-stress mismatch between elastic recovery and hydrogel swelling. Unlike conventional bilayer hydrogel actuators based on differential swelling between laminated layers, this pre-stretching strategy amplifies structural deformation through elastic restoring stress. When extended to a two-dimensional textile architecture, this strategy enables reversible, dynamic pore modulation with an approximately 400% increase in pore area. This study provides a promising platform for smart adaptive textiles, wearable healthcare, and soft robotics.
Open AccessShape-Controlled Poly(N-isopropylacrylamide) Actuators Enabled by Tensile-Stress Mismatch for Temperature-Adaptive Textiles
Thermal comfort is a key determinant of human health and requires adaptive responses to dynamic environments. Here, we report a temperature-adaptive textile enabled by a tensile stress mismatch-driven poly(N-isopropylacrylamide) (PNIPAM) actuator operating within a human-friendly temperature range of 18–38 °C. A pre-stretched polyurethane core fiber integrated within a PNIPAM sheath in a noncoaxial configuration induces programmable bending through tensile-stress mismatch between elastic recovery and hydrogel swelling. Unlike conventional bilayer hydrogel actuators based on differential swelling between laminated layers, this pre-stretching strategy amplifies structural deformation through elastic restoring stress. When extended to a two-dimensional textile architecture, this strategy enables reversible, dynamic pore modulation with an approximately 400% increase in pore area. This study provides a promising platform for smart adaptive textiles, wearable healthcare, and soft robotics.
- Open Access
- 19 February 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (2) , 210
Poly(N-isopropylacrylamide) Hydrogel for Diving/Surfacing Device
Underwater robots and vehicles have received great attention due to their potential applications in remote sensing and search and rescue. A challenge for micro aquatic robots is the lack of small motors needed for three-dimensional locomotion in water. Here, we show a simple diving and surfacing device fabricated from thermo-sensitive poly(N-isopropylacrylamide) or a poly(N-isopropylacrylamide)-containing hydrogel. The poly(N-isopropylacrylamide)-containing device exhibited fast and reversible diving/surfacing cycles in response to changing temperature. Modulation of the interaction between poly(N-isopropylacrylamide) chains and water molecules at temperatures above or below the lower critical solution temperature regulates the gel density through the swelling and de-swelling. The gel surfaced in water when heated and sank when cooled. We further showed reversible diving/surfacing cycles of the device when exposed to electrical and ultrasonic stimuli. Finally, a small electrically heated gel was incorporated into a miniature submarine and used to control the diving depth. These results suggest that the poly(N-isopropylacrylamide)-containing device has good potential for underwater remote-controlled micro aquatic robots.
- 19 February 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (2) , 210
Open AccessPoly(N-isopropylacrylamide) Hydrogel for Diving/Surfacing Device
Underwater robots and vehicles have received great attention due to their potential applications in remote sensing and search and rescue. A challenge for micro aquatic robots is the lack of small motors needed for three-dimensional locomotion in water. Here, we show a simple diving and surfacing device fabricated from thermo-sensitive poly(N-isopropylacrylamide) or a poly(N-isopropylacrylamide)-containing hydrogel. The poly(N-isopropylacrylamide)-containing device exhibited fast and reversible diving/surfacing cycles in response to changing temperature. Modulation of the interaction between poly(N-isopropylacrylamide) chains and water molecules at temperatures above or below the lower critical solution temperature regulates the gel density through the swelling and de-swelling. The gel surfaced in water when heated and sank when cooled. We further showed reversible diving/surfacing cycles of the device when exposed to electrical and ultrasonic stimuli. Finally, a small electrically heated gel was incorporated into a miniature submarine and used to control the diving depth. These results suggest that the poly(N-isopropylacrylamide)-containing device has good potential for underwater remote-controlled micro aquatic robots.