Andrew J. Badby
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrew J. Badby has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Paul Comfort
Centre for Human Movement and Rehabilitation Science, School of Health and Society, University of Salford, Salford, United Kingdom
4 shared publicationsJohn J. McMahon
Centre for Human Movement and Rehabilitation Science, School of Health and Society, University of Salford, Salford, United Kingdom
3 shared publicationsNicholas J. Ripley
Centre for Human Movement and Rehabilitation Science, School of Health and Society, University of Salford, Salford, United Kingdom
3 shared publicationsPeter D. Mundy
Hawkin Dynamics, Inc., Westbrook, Maine; and
3 shared publications- John James McMahon
School of Health and Society, University of Salford, Salford M5 4WT, UK
2 shared publications - Paul Comfort
School of Health and Society, University of Salford, Salford, United Kingdom
2 shared publications
Latest Publications
- 13 May 2026
- Published by Wolters Kluwer Health in Journal of Strength & Conditioning Research
- Vol. 40 (8) , e866-e875
Which Metrics Should I Monitor? Recommendations for Monitoring Acute Changes in Physical Preparedness With Countermovement Jump Force-Time Metrics in Youth Soccer Players In-Season
Badby, AJ, Ripley, NJ, McMahon, JJ, Mundy, PD, and Comfort, P. Which metrics should I monitor? Recommendations for monitoring acute changes in physical preparedness with countermovement jump force-time metrics in youth soccer players in-season. J Strength Cond Res XX(X): 000–000, 2026—The aim of this study was to determine the effectiveness of utilizing countermovement jump (CMJ) testing using force plates to monitor acute changes in lower-body neuromuscular function (NMF) resulting from in-season competitive match play in soccer athletes. A within-subjects, observational, cross-sectional, repeated-measures study design consisting of 3 in-season testing occasions was prescribed across 3 separate competitive soccer matches: immediately prematch (∼15 minutes), immediately postmatch (∼15 minutes), and ∼48 hours postmatch (match day [MD] +2). Youth Alliance League (U18) soccer players ( N = 27; age 16.9 ± 0.7 years; height 181.4 ± 5.4 cm; mass 73.6 ± 9.1 kg) were recruited from 3 professional English Football League clubs. A repeated-measures analysis of variance demonstrated significant differences ( p < 0.05) across testing timepoints for all metrics except peak propulsive force. Mass-relative (including outcome) metrics cannot be utilized alone for monitoring acute changes in NMF, as significant reductions ( p < 0.001) in body weight were identified from immediately pre- to immediately postmatch and from immediately postmatch to MD+2. Significant reductions ( p < 0.05) from immediately pre- to immediately postmatch (which were maintained at MD+2) in mean propulsive force (minimal detectable change [MDC] = 7.43%), mean propulsive velocity (MDC = 4.93%), mean propulsive power (MDC = 9.38%), and jump momentum (MDC = 4.43%) indicate that these metrics are sensitive to changes in NMF. If utilizing outcome metrics (e.g., jump height; MDC = 8.55%) in addition to these, collectively, monitoring this combination of metrics (and body weight; MDC = 1.37%) will help to explain both if and why any changes in the outcome occur following soccer match play, thus providing valuable context when utilizing the CMJ as an indicator of acute changes in NMF.
- 13 May 2026
- Published by Wolters Kluwer Health in Journal of Strength & Conditioning Research
- Vol. 40 (8) , e866-e875
Which Metrics Should I Monitor? Recommendations for Monitoring Acute Changes in Physical Preparedness With Countermovement Jump Force-Time Metrics in Youth Soccer Players In-Season
Badby, AJ, Ripley, NJ, McMahon, JJ, Mundy, PD, and Comfort, P. Which metrics should I monitor? Recommendations for monitoring acute changes in physical preparedness with countermovement jump force-time metrics in youth soccer players in-season. J Strength Cond Res XX(X): 000–000, 2026—The aim of this study was to determine the effectiveness of utilizing countermovement jump (CMJ) testing using force plates to monitor acute changes in lower-body neuromuscular function (NMF) resulting from in-season competitive match play in soccer athletes. A within-subjects, observational, cross-sectional, repeated-measures study design consisting of 3 in-season testing occasions was prescribed across 3 separate competitive soccer matches: immediately prematch (∼15 minutes), immediately postmatch (∼15 minutes), and ∼48 hours postmatch (match day [MD] +2). Youth Alliance League (U18) soccer players ( N = 27; age 16.9 ± 0.7 years; height 181.4 ± 5.4 cm; mass 73.6 ± 9.1 kg) were recruited from 3 professional English Football League clubs. A repeated-measures analysis of variance demonstrated significant differences ( p < 0.05) across testing timepoints for all metrics except peak propulsive force. Mass-relative (including outcome) metrics cannot be utilized alone for monitoring acute changes in NMF, as significant reductions ( p < 0.001) in body weight were identified from immediately pre- to immediately postmatch and from immediately postmatch to MD+2. Significant reductions ( p < 0.05) from immediately pre- to immediately postmatch (which were maintained at MD+2) in mean propulsive force (minimal detectable change [MDC] = 7.43%), mean propulsive velocity (MDC = 4.93%), mean propulsive power (MDC = 9.38%), and jump momentum (MDC = 4.43%) indicate that these metrics are sensitive to changes in NMF. If utilizing outcome metrics (e.g., jump height; MDC = 8.55%) in addition to these, collectively, monitoring this combination of metrics (and body weight; MDC = 1.37%) will help to explain both if and why any changes in the outcome occur following soccer match play, thus providing valuable context when utilizing the CMJ as an indicator of acute changes in NMF.
- Open Access
- 11 July 2025
- Published by Taylor & Francis in Journal of Sports Sciences
- p. 1-18
Normative data and objective benchmarks for selected force plate tests for professional and youth soccer players in the English Football League
The aim of this study was to establish objective benchmarks for countermovement jump (CMJ), countermovement rebound jump (CMRJ), and isometric mid-thigh pull (IMTP) metrics in male professional and youth soccer players. Professional (N = 139; age: 24 ± 5 years; height: 184 ± 7 cm; mass: 81 ± 9 kg) and youth (N = 137; age: 17 ± 1 years; height: 178 ± 17 cm; mass: 72 ± 8 kg) soccer players were recruited from 7 separate clubs. Many CMJ (25/32), CMRJ (24/30), and (2/2) IMTP metrics discriminated between age groups. Significant (p < 0.05) differences were identified in CMJ outcome (4/4), propulsive kinetic (6/6), and relative propulsive kinetic (4/4) metrics, but trivial non-significant (p > 0.05) differences were identified in strategy (4/4) metrics. Rebound jump portion propulsive kinetic (4/4) metrics and braking depth demonstrated moderate to large differences between groups, but only one relative propulsive kinetic (1/4) metric demonstrated significant (p < 0.01) differences. Professional soccer players also demonstrated significantly (p < 0.001) greater IMTP peak force (3031 ± 549 N vs 2441 ± 452 N; g = 0.788) and relative peak force (37.39 ± 5.35 N/kg vs 34.01 ± 4.74 N/kg; g = 0.446) than youth soccer players.
- 11 July 2025
- Published by Taylor & Francis in Journal of Sports Sciences
- p. 1-18
Open AccessNormative data and objective benchmarks for selected force plate tests for professional and youth soccer players in the English Football League
The aim of this study was to establish objective benchmarks for countermovement jump (CMJ), countermovement rebound jump (CMRJ), and isometric mid-thigh pull (IMTP) metrics in male professional and youth soccer players. Professional (N = 139; age: 24 ± 5 years; height: 184 ± 7 cm; mass: 81 ± 9 kg) and youth (N = 137; age: 17 ± 1 years; height: 178 ± 17 cm; mass: 72 ± 8 kg) soccer players were recruited from 7 separate clubs. Many CMJ (25/32), CMRJ (24/30), and (2/2) IMTP metrics discriminated between age groups. Significant (p < 0.05) differences were identified in CMJ outcome (4/4), propulsive kinetic (6/6), and relative propulsive kinetic (4/4) metrics, but trivial non-significant (p > 0.05) differences were identified in strategy (4/4) metrics. Rebound jump portion propulsive kinetic (4/4) metrics and braking depth demonstrated moderate to large differences between groups, but only one relative propulsive kinetic (1/4) metric demonstrated significant (p < 0.01) differences. Professional soccer players also demonstrated significantly (p < 0.001) greater IMTP peak force (3031 ± 549 N vs 2441 ± 452 N; g = 0.788) and relative peak force (37.39 ± 5.35 N/kg vs 34.01 ± 4.74 N/kg; g = 0.446) than youth soccer players.
- Top Cited PapersOpen Access
- 9 May 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (5) , e0322820
Scoping review of methods of monitoring acute changes in lower body neuromuscular function via force plates
Force plates are amongst the most utilised technological apparatus for monitoring acute changes in neuromuscular function in sports. Practitioners apply monitoring strategies to manage neuromuscular fatigue and physical preparedness with valid, reliable, and sensitive measures. The aim of this scoping review was to identify, map, and describe the variety of monitoring procedures which have been previously applied in research (e.g., test and metric selection, data collection, study design, and data analysis procedures). Searches were completed by 24th June 2024. One thousand, nine hundred, and seventy-eight studies were identified across four databases (PubMed, EBSCO, Clarivate web of science, and Ovid). After removing duplicates, applying the inclusion criteria, and scouring the reference lists of remaining studies, a final total of thirty studies of within-group repeated measures design were used in this review. Major differences were identified across all aspects of studies methodologies, such as in subject demographics (e.g., sex, sport, and competitive level), data collection protocols (e.g., force plate hardware utilised, test and metric selection, verbal cues, and provision of information regarding testing surface, familiarisation and warm-up provided, the process of zeroing force plates between trials, and weighing of subjects during trials), and study design (e.g., reference physical activity investigated, time of season, testing timepoints, and training load determination). A general lack of reporting and uniformity in metric definitions, metric calculations, and phase terminology was identified across studies. For example, two separate calculations were reported for “peak force” across studies, as either “the maximum force achieved throughout the entirety of the trial”, or as “the maximum force achieved during the propulsion phase”. The latter calculation was also utilised for “peak concentric force” in a separate study. Thus, an accurate comparison of results across studies (e.g., via meta-analysis) and forming any generalized conclusions about the application of specific tests and metrics for monitoring acute changes in neuromuscular function using force plates was premature at this time. The information presented in this review will contribute towards forming a rationale for the data collection, study design, and data analysis protocols for future research on monitoring acute changes in neuromuscular function using force plates.
- 9 May 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (5) , e0322820
Top Cited PapersOpen AccessScoping review of methods of monitoring acute changes in lower body neuromuscular function via force plates
Force plates are amongst the most utilised technological apparatus for monitoring acute changes in neuromuscular function in sports. Practitioners apply monitoring strategies to manage neuromuscular fatigue and physical preparedness with valid, reliable, and sensitive measures. The aim of this scoping review was to identify, map, and describe the variety of monitoring procedures which have been previously applied in research (e.g., test and metric selection, data collection, study design, and data analysis procedures). Searches were completed by 24th June 2024. One thousand, nine hundred, and seventy-eight studies were identified across four databases (PubMed, EBSCO, Clarivate web of science, and Ovid). After removing duplicates, applying the inclusion criteria, and scouring the reference lists of remaining studies, a final total of thirty studies of within-group repeated measures design were used in this review. Major differences were identified across all aspects of studies methodologies, such as in subject demographics (e.g., sex, sport, and competitive level), data collection protocols (e.g., force plate hardware utilised, test and metric selection, verbal cues, and provision of information regarding testing surface, familiarisation and warm-up provided, the process of zeroing force plates between trials, and weighing of subjects during trials), and study design (e.g., reference physical activity investigated, time of season, testing timepoints, and training load determination). A general lack of reporting and uniformity in metric definitions, metric calculations, and phase terminology was identified across studies. For example, two separate calculations were reported for “peak force” across studies, as either “the maximum force achieved throughout the entirety of the trial”, or as “the maximum force achieved during the propulsion phase”. The latter calculation was also utilised for “peak concentric force” in a separate study. Thus, an accurate comparison of results across studies (e.g., via meta-analysis) and forming any generalized conclusions about the application of specific tests and metrics for monitoring acute changes in neuromuscular function using force plates was premature at this time. The information presented in this review will contribute towards forming a rationale for the data collection, study design, and data analysis protocols for future research on monitoring acute changes in neuromuscular function using force plates.
- Open Access
- 3 January 2025
- Published by International Universities Strength and Conditioning Association in International Journal of Strength and Conditioning
- Vol. 5 (1)
Which Metrics Can I Monitor? Test-Retest Reliability of Countermovement Jump and Countermovement Rebound Jump Force-Time Metrics in Youth Soccer Players In-Season
Objective measures provide the most effective means of monitoring the magnitude and time course of changes in neuromuscular function (NMF) resulting from physical activity if measurements are repeatable (reliability). The aim of this study was to determine the test-retest reliability of a range of ratio, outcome, strategy, and kinetic force plate metrics for the countermovement jump (CMJ) and countermovement rebound jump (CMRJ) tests in youth soccer players in the in-season period. A test-retest repeated-measures design was employed consisting of two testing sessions separated by 7-days. In each testing session, male youth soccer players (N = 43; age 17.9 ± 0.9 years, height 181 ± 5.8 cm, body mass 72.5 ± 6.8 kg) from full-time English Football League academies (categories 2 and 4) performed three maximal-effort CMJs and CMRJs in a randomised order on a Hawkin Dynamics Inc. force plate system sampled at 1000 Hz. Fifteen out of 25 CMJ, 11 out of 19 CMJ portion, and five out of 19 rebound jump (RJ) portion metrics demonstrated acceptable absolute (coefficient of variation [CV] ≤10%) and relative (intraclass correlation coefficient [ICC] ≥0.75) reliability for youth soccer players in the in-season period. The CMJ test is a feasible and reliable slow stretch-shortening cycle (SSC) test which can be utilised for monitoring acute changes in NMF in youth soccer players in-season. Practitioners should consider applying a combination of CMJ outcome, strategy, and kinetic metrics in their monitoring processes. The CMRJ test is a less feasible yet reliable fast SSC test which can be utilised for monitoring acute changes in NMF in youth soccer players in-season and can be considered an appropriate alternative to the drop jump (DJ) test as it overcame issues in DJ fall height variability identified in previous research, where acceptable reliability was demonstrated in CMJ portion bodyweight and all outcome metrics.
- 3 January 2025
- Published by International Universities Strength and Conditioning Association in International Journal of Strength and Conditioning
- Vol. 5 (1)
Open AccessWhich Metrics Can I Monitor? Test-Retest Reliability of Countermovement Jump and Countermovement Rebound Jump Force-Time Metrics in Youth Soccer Players In-Season
Objective measures provide the most effective means of monitoring the magnitude and time course of changes in neuromuscular function (NMF) resulting from physical activity if measurements are repeatable (reliability). The aim of this study was to determine the test-retest reliability of a range of ratio, outcome, strategy, and kinetic force plate metrics for the countermovement jump (CMJ) and countermovement rebound jump (CMRJ) tests in youth soccer players in the in-season period. A test-retest repeated-measures design was employed consisting of two testing sessions separated by 7-days. In each testing session, male youth soccer players (N = 43; age 17.9 ± 0.9 years, height 181 ± 5.8 cm, body mass 72.5 ± 6.8 kg) from full-time English Football League academies (categories 2 and 4) performed three maximal-effort CMJs and CMRJs in a randomised order on a Hawkin Dynamics Inc. force plate system sampled at 1000 Hz. Fifteen out of 25 CMJ, 11 out of 19 CMJ portion, and five out of 19 rebound jump (RJ) portion metrics demonstrated acceptable absolute (coefficient of variation [CV] ≤10%) and relative (intraclass correlation coefficient [ICC] ≥0.75) reliability for youth soccer players in the in-season period. The CMJ test is a feasible and reliable slow stretch-shortening cycle (SSC) test which can be utilised for monitoring acute changes in NMF in youth soccer players in-season. Practitioners should consider applying a combination of CMJ outcome, strategy, and kinetic metrics in their monitoring processes. The CMRJ test is a less feasible yet reliable fast SSC test which can be utilised for monitoring acute changes in NMF in youth soccer players in-season and can be considered an appropriate alternative to the drop jump (DJ) test as it overcame issues in DJ fall height variability identified in previous research, where acceptable reliability was demonstrated in CMJ portion bodyweight and all outcome metrics.
- Open Access
- 30 November 2023
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 8 (4) , 164
The Kneeling Isometric Plantar Flexor Test: Preliminary Reliability and Feasibility in Professional Youth Football
Calf injuries are common in professional football; thus, the establishment of reliable and time-efficient methods of measuring the peak force capabilities of the plantar flexors with equipment that is accessible to football practitioners is valuable. In this study, we determined the preliminary reliability and feasibility of a new test, termed the kneeling isometric plantar flexion test (KIPFT), for footballers. Twenty-one male youth footballers (age = 17.8 ± 1.1 years, height = 182 ± 5 cm, weight = 77.6 ± 5.9 kg) from English League One football clubs completed three trials of the KIPFT on a wireless force plate at the end (2022–2023) and start (2023–2024) of the season. The within-session reliability of the peak force (relative to body weight) was good–excellent for both limbs and both occasions. On average, performance of the KIPFT took just over 1 min per limb and ~2 min to set up. The peak force values were larger for the non-dominant limbs only at the start versus the end of the season, but there were no between-limb differences. From these results, it was determined that (1) the KIPFT is feasible, (2) a minimum of 32 footballers would be required to establish its between-session reliability with ≥80% statistical power and (3) large-cohort normative data for the KIPFT may be best collected at the start of the football season.
- 30 November 2023
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 8 (4) , 164
Open AccessThe Kneeling Isometric Plantar Flexor Test: Preliminary Reliability and Feasibility in Professional Youth Football
Calf injuries are common in professional football; thus, the establishment of reliable and time-efficient methods of measuring the peak force capabilities of the plantar flexors with equipment that is accessible to football practitioners is valuable. In this study, we determined the preliminary reliability and feasibility of a new test, termed the kneeling isometric plantar flexion test (KIPFT), for footballers. Twenty-one male youth footballers (age = 17.8 ± 1.1 years, height = 182 ± 5 cm, weight = 77.6 ± 5.9 kg) from English League One football clubs completed three trials of the KIPFT on a wireless force plate at the end (2022–2023) and start (2023–2024) of the season. The within-session reliability of the peak force (relative to body weight) was good–excellent for both limbs and both occasions. On average, performance of the KIPFT took just over 1 min per limb and ~2 min to set up. The peak force values were larger for the non-dominant limbs only at the start versus the end of the season, but there were no between-limb differences. From these results, it was determined that (1) the KIPFT is feasible, (2) a minimum of 32 footballers would be required to establish its between-session reliability with ≥80% statistical power and (3) large-cohort normative data for the KIPFT may be best collected at the start of the football season.
- Top Cited PapersOpen Access
The Validity of Hawkin Dynamics Wireless Dual Force Plates for Measuring Countermovement Jump and Drop Jump Variables
Force plate testing is becoming more commonplace in sport due to the advent of commercially available, portable, and affordable force plate systems (i.e., hardware and software). Following the validation of the Hawkin Dynamics Inc. (HD) proprietary software in recent literature, the aim of this study was to determine the concurrent validity of the HD wireless dual force plate hardware for assessing vertical jumps. During a single testing session, the HD force plates were placed directly atop two adjacent Advanced Mechanical Technology Inc. in-ground force plates (the “gold standard”) to simultaneously collect vertical ground reaction forces produced by 20 participants (27 ± 6 years, 85 ± 14 kg, 176.5 ± 9.23 cm) during the countermovement jump (CMJ) and drop jump (DJ) tests (1000 Hz). Agreement between force plate systems was determined via ordinary least products regression using bootstrapped 95% confidence intervals. No bias was present between the two force plate systems for any of the CMJ and DJ variables, except DJ peak braking force (proportional bias) and DJ peak braking power (fixed and proportional bias). The HD system may be considered a valid alternative to the industry gold standard for assessing vertical jumps because fixed or proportional bias was identified for none of the CMJ variables (n = 17) and only 2 out of 18 DJ variables.
Top Cited PapersOpen AccessThe Validity of Hawkin Dynamics Wireless Dual Force Plates for Measuring Countermovement Jump and Drop Jump Variables
Force plate testing is becoming more commonplace in sport due to the advent of commercially available, portable, and affordable force plate systems (i.e., hardware and software). Following the validation of the Hawkin Dynamics Inc. (HD) proprietary software in recent literature, the aim of this study was to determine the concurrent validity of the HD wireless dual force plate hardware for assessing vertical jumps. During a single testing session, the HD force plates were placed directly atop two adjacent Advanced Mechanical Technology Inc. in-ground force plates (the “gold standard”) to simultaneously collect vertical ground reaction forces produced by 20 participants (27 ± 6 years, 85 ± 14 kg, 176.5 ± 9.23 cm) during the countermovement jump (CMJ) and drop jump (DJ) tests (1000 Hz). Agreement between force plate systems was determined via ordinary least products regression using bootstrapped 95% confidence intervals. No bias was present between the two force plate systems for any of the CMJ and DJ variables, except DJ peak braking force (proportional bias) and DJ peak braking power (fixed and proportional bias). The HD system may be considered a valid alternative to the industry gold standard for assessing vertical jumps because fixed or proportional bias was identified for none of the CMJ variables (n = 17) and only 2 out of 18 DJ variables.