Massimo Dall’olio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Massimo Dall’olio has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Claudio Borghi
Department of Medical and Surgical Sciences, University of Bologna, 40126 Bologna, Italy
3 shared publications - Ilaria Gallelli
IRCCS AOU, Policlinico di S. Orsola, 40138 Bologna, Italy
3 shared publications - Luca Neri
Department of Medicine, Division of Cardiology, Johns Hopkins University, Baltimore, MD 21218, USA
2 shared publications - Alessandro Orro
Institute of Biomedical Technologies CNR, Via Fratelli Cervi, 93, 20054 Segrate, Italy
1 shared publication Alexander Adorno
University of Bologna
1 shared publication- Amir Beker
AccYouRate Group S.p.A., 67100 L’Aquila, Italy
1 shared publication
Latest Publications
- Open Access
- 20 November 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (22) , 8226
Middle Meningeal Artery Embolization in the Treatment of Chronic Subdural Hematoma: A Two-Center Retrospective Study
Background: Chronic subdural hematoma (cSDH) is a common condition, particularly in individuals over 65 years of age. Its pathophysiology involves traumatic and inflammatory processes, culminating in hematoma formation. Although surgical drainage is the primary treatment of choice, its significant recurrence rates have prompted exploration of non-surgical options. This study evaluates the effectiveness of middle meningeal artery (MMA) embolization as an alternative or adjunctive treatment in asymptomatic or paucisymptomatic cSDH patients. Methods: This two-center retrospective study analyzed 93 patients treated with MMA embolization at two hospitals between 2020 and 2024. Patients exhibited either asymptomatic or mild symptomatic cSDH (Markwalder score 0 or 1), with hematoma thickness >10 mm. Pre- and post-treatment CT scans were compared to assess hematoma thickness, with follow-ups conducted at three months. Statistical analysis included ANCOVA and Mann–Whitney U tests for outcome evaluation. Results: Of the 93 patients, 44 underwent bilateral embolization, and 49 underwent unilateral embolization. Treatment reduced hematoma thickness by an average of 59% at three months follow-up. The trabecular subtype showed the greatest thickness reduction compared to other subtypes (p < 0.05). No significant differences were found between embolization materials. Only 3.2% of patients experienced technical complications, and three patients experienced rebleeding during follow-up. Conclusions: MMA embolization appears to be a safe and effective treatment for cSDH, providing a minimally invasive alternative to surgery. The technique shows promise in reducing hematoma size, especially in the trabecular subtype. Further research is needed to confirm these findings and establish their role in routine clinical practice.
- 20 November 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (22) , 8226
Open AccessMiddle Meningeal Artery Embolization in the Treatment of Chronic Subdural Hematoma: A Two-Center Retrospective Study
Background: Chronic subdural hematoma (cSDH) is a common condition, particularly in individuals over 65 years of age. Its pathophysiology involves traumatic and inflammatory processes, culminating in hematoma formation. Although surgical drainage is the primary treatment of choice, its significant recurrence rates have prompted exploration of non-surgical options. This study evaluates the effectiveness of middle meningeal artery (MMA) embolization as an alternative or adjunctive treatment in asymptomatic or paucisymptomatic cSDH patients. Methods: This two-center retrospective study analyzed 93 patients treated with MMA embolization at two hospitals between 2020 and 2024. Patients exhibited either asymptomatic or mild symptomatic cSDH (Markwalder score 0 or 1), with hematoma thickness >10 mm. Pre- and post-treatment CT scans were compared to assess hematoma thickness, with follow-ups conducted at three months. Statistical analysis included ANCOVA and Mann–Whitney U tests for outcome evaluation. Results: Of the 93 patients, 44 underwent bilateral embolization, and 49 underwent unilateral embolization. Treatment reduced hematoma thickness by an average of 59% at three months follow-up. The trabecular subtype showed the greatest thickness reduction compared to other subtypes (p < 0.05). No significant differences were found between embolization materials. Only 3.2% of patients experienced technical complications, and three patients experienced rebleeding during follow-up. Conclusions: MMA embolization appears to be a safe and effective treatment for cSDH, providing a minimally invasive alternative to surgery. The technique shows promise in reducing hematoma size, especially in the trabecular subtype. Further research is needed to confirm these findings and establish their role in routine clinical practice.
- Open Access
- 26 February 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (3) , 222
Validation of a New and Straightforward Algorithm to Evaluate Signal Quality during ECG Monitoring with Wearable Devices Used in a Clinical Setting
Background: Wearable devices represent a new approach for monitoring key clinical parameters, such as ECG signals, for research and health purposes. These devices could outcompete medical devices in terms of affordability and use in out-clinic settings, allowing remote monitoring. The major limitation, especially when compared to implantable devices, is the presence of artifacts. Several authors reported a relevant percentage of recording time with poor/unusable traces for ECG, potentially hampering the use of these devices for this purpose. For this reason, it is of the utmost importance to develop a simple and inexpensive system enabling the user of the wearable devices to have immediate feedback on the quality of the acquired signal, allowing for real-time correction. Methods: A simple algorithm that can work in real time to verify the quality of the ECG signal (acceptable and unacceptable) was validated. Based on simple statistical parameters, the algorithm was blindly tested by comparison with ECG tracings previously classified by two expert cardiologists. Results: The classifications of 7200 10s-signal samples acquired on 20 patients with a commercial wearable ECG monitor were compared. The algorithm has an overall efficiency of approximately 95%, with a sensitivity of 94.7% and a specificity of 95.3%. Conclusions: The results demonstrate that even a simple algorithm can be used to classify signal coarseness, and this could allow real-time intervention by the subject or the technician.
- 26 February 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (3) , 222
Open AccessValidation of a New and Straightforward Algorithm to Evaluate Signal Quality during ECG Monitoring with Wearable Devices Used in a Clinical Setting
Background: Wearable devices represent a new approach for monitoring key clinical parameters, such as ECG signals, for research and health purposes. These devices could outcompete medical devices in terms of affordability and use in out-clinic settings, allowing remote monitoring. The major limitation, especially when compared to implantable devices, is the presence of artifacts. Several authors reported a relevant percentage of recording time with poor/unusable traces for ECG, potentially hampering the use of these devices for this purpose. For this reason, it is of the utmost importance to develop a simple and inexpensive system enabling the user of the wearable devices to have immediate feedback on the quality of the acquired signal, allowing for real-time correction. Methods: A simple algorithm that can work in real time to verify the quality of the ECG signal (acceptable and unacceptable) was validated. Based on simple statistical parameters, the algorithm was blindly tested by comparison with ECG tracings previously classified by two expert cardiologists. Results: The classifications of 7200 10s-signal samples acquired on 20 patients with a commercial wearable ECG monitor were compared. The algorithm has an overall efficiency of approximately 95%, with a sensitivity of 94.7% and a specificity of 95.3%. Conclusions: The results demonstrate that even a simple algorithm can be used to classify signal coarseness, and this could allow real-time intervention by the subject or the technician.
- Top Cited PapersOpen Access
Electrocardiogram Monitoring Wearable Devices and Artificial-Intelligence-Enabled Diagnostic Capabilities: A Review
Worldwide, population aging and unhealthy lifestyles have increased the incidence of high-risk health conditions such as cardiovascular diseases, sleep apnea, and other conditions. Recently, to facilitate early identification and diagnosis, efforts have been made in the research and development of new wearable devices to make them smaller, more comfortable, more accurate, and increasingly compatible with artificial intelligence technologies. These efforts can pave the way to the longer and continuous health monitoring of different biosignals, including the real-time detection of diseases, thus providing more timely and accurate predictions of health events that can drastically improve the healthcare management of patients. Most recent reviews focus on a specific category of disease, the use of artificial intelligence in 12-lead electrocardiograms, or on wearable technology. However, we present recent advances in the use of electrocardiogram signals acquired with wearable devices or from publicly available databases and the analysis of such signals with artificial intelligence methods to detect and predict diseases. As expected, most of the available research focuses on heart diseases, sleep apnea, and other emerging areas, such as mental stress. From a methodological point of view, although traditional statistical methods and machine learning are still widely used, we observe an increasing use of more advanced deep learning methods, specifically architectures that can handle the complexity of biosignal data. These deep learning methods typically include convolutional and recurrent neural networks. Moreover, when proposing new artificial intelligence methods, we observe that the prevalent choice is to use publicly available databases rather than collecting new data.
Top Cited PapersOpen AccessElectrocardiogram Monitoring Wearable Devices and Artificial-Intelligence-Enabled Diagnostic Capabilities: A Review
Worldwide, population aging and unhealthy lifestyles have increased the incidence of high-risk health conditions such as cardiovascular diseases, sleep apnea, and other conditions. Recently, to facilitate early identification and diagnosis, efforts have been made in the research and development of new wearable devices to make them smaller, more comfortable, more accurate, and increasingly compatible with artificial intelligence technologies. These efforts can pave the way to the longer and continuous health monitoring of different biosignals, including the real-time detection of diseases, thus providing more timely and accurate predictions of health events that can drastically improve the healthcare management of patients. Most recent reviews focus on a specific category of disease, the use of artificial intelligence in 12-lead electrocardiograms, or on wearable technology. However, we present recent advances in the use of electrocardiogram signals acquired with wearable devices or from publicly available databases and the analysis of such signals with artificial intelligence methods to detect and predict diseases. As expected, most of the available research focuses on heart diseases, sleep apnea, and other emerging areas, such as mental stress. From a methodological point of view, although traditional statistical methods and machine learning are still widely used, we observe an increasing use of more advanced deep learning methods, specifically architectures that can handle the complexity of biosignal data. These deep learning methods typically include convolutional and recurrent neural networks. Moreover, when proposing new artificial intelligence methods, we observe that the prevalent choice is to use publicly available databases rather than collecting new data.
- 1 January 2023
- Published by Springer Nature
- p. 139-154
The Role of Uric Acid in Hypertension and Heart Failure
- 1 January 2023
- Published by Springer Nature
- p. 139-154
The Role of Uric Acid in Hypertension and Heart Failure