Rezeda Shamagsumova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rezeda Shamagsumova has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Anna Porfireva
A.M. Butlerov’ Chemistry Institute, Kazan Federal University, 18 Kremlevskaya Street, Kazan 420008, Russia
8 shared publications - Gennady Evtugyn
Kazan Federal University
5 shared publications - Tatjana Kulikova
A.M. Butlerov’ Chemistry Institute, Kazan Federal University, 18 Kremlevskaya Street, Kazan 420008, Russia
5 shared publications - Ivan I. Stoikov
Alexander Butlerov Institute of Chemistry, Kazan Federal University, 18 Kremlevskaya Street, Kazan 420008, Russia
4 shared publications - Anastasia Malanina
A.M. Butlerov’ Chemistry Institute, Kazan Federal University, 18 Kremlevskaya Street, Kazan 420008, Russia
3 shared publications - Vladimir Evtugyn
A.M. Butlerov Chemical Institute, Kazan Federal University, 18 Kremlyovskaya Str., 420008 Kazan, Russia
3 shared publications
Latest Publications
- Open Access
- 9 September 2026
- Published by Kazan Federal University in Uchenye Zapiski Kazanskogo Universiteta. Seriya Estestvennye Nauki
- Vol. 168 (3) , 397-418
Application of PAMAM dendrimers in electrochemical aptasensor for semi-quantitative determination of heart fatty acid-binding protein
A voltammetric aptasensor for the determination of heart fatty acid-binding protein (hFABP), an early biomarker of acute myocardial infarction, in human blood serum was developed by incorporating an aptamer for hFABP into the surface layer of the aptasensor. The covalent attachment of the aptamer provided better analytical performance than physical immobilization. The optimal analytical conditions were established: pH, Methylene green concentration as a redox probe, and hFABP incubation time. Glassy carbon electrode modified with carbon black and unmodified screen-printed carbon electrodes were used as electrochemical transducers. The electrochemical parameters of different aptasensor variants were compared. The introduction of second generation dendrimers based on thiacalix[4]arenes improved the sensitivity of the aptasensor by lowering the hFABP limit of detection (LOD). The type of dendrimer configuration was found to influence the aptasensor performance. For semi-quantitative determination of hFABP, an aptasensor variant based on disposable printed electrodes modified with the aptamer and a dendrimer containing the macrocyclic core in the 1,3-alternate conformation was proposed. It had a linear range of 15–75 ng/mL with 7.5 ng/mL LOD. The dilution 1 : 2 of the biological samples with buffer reduced the matrix interference, enabling reliable semi-quantitative determination of hFABP at clinically relevant concentrations of 45–60 ng/mL and indicating its potential for rapid detection of acute myocardial infarction.
- 9 September 2026
- Published by Kazan Federal University in Uchenye Zapiski Kazanskogo Universiteta. Seriya Estestvennye Nauki
- Vol. 168 (3) , 397-418
Open AccessApplication of PAMAM dendrimers in electrochemical aptasensor for semi-quantitative determination of heart fatty acid-binding protein
A voltammetric aptasensor for the determination of heart fatty acid-binding protein (hFABP), an early biomarker of acute myocardial infarction, in human blood serum was developed by incorporating an aptamer for hFABP into the surface layer of the aptasensor. The covalent attachment of the aptamer provided better analytical performance than physical immobilization. The optimal analytical conditions were established: pH, Methylene green concentration as a redox probe, and hFABP incubation time. Glassy carbon electrode modified with carbon black and unmodified screen-printed carbon electrodes were used as electrochemical transducers. The electrochemical parameters of different aptasensor variants were compared. The introduction of second generation dendrimers based on thiacalix[4]arenes improved the sensitivity of the aptasensor by lowering the hFABP limit of detection (LOD). The type of dendrimer configuration was found to influence the aptasensor performance. For semi-quantitative determination of hFABP, an aptasensor variant based on disposable printed electrodes modified with the aptamer and a dendrimer containing the macrocyclic core in the 1,3-alternate conformation was proposed. It had a linear range of 15–75 ng/mL with 7.5 ng/mL LOD. The dilution 1 : 2 of the biological samples with buffer reduced the matrix interference, enabling reliable semi-quantitative determination of hFABP at clinically relevant concentrations of 45–60 ng/mL and indicating its potential for rapid detection of acute myocardial infarction.
- Open Access
- 25 June 2026
- Published by Ural Federal University in Chimica Techno Acta
- Vol. 13 (4) , 10223
Electrochemical DNA sensor based on electropolymerized 2,3-diaminophenazine for detection of intercalative DNA damage in presence of copper ions
The electrochemical parameters of 2,3-diaminophenazine (DAP) and its polymeric form (PDAP) electrodeposited from the perchloric acid on the screen-printed carbon electrodes (SPCE) were investigated. The electropolymerized PDAP coating was used with native DNA from various sources (calf thymus, salmon sperm, herring sperm, chicken erythrocytes) for the DNA sensor assembly. The layer-by-layer assembly of the DNA sensor was controlled by voltammetric and impedimetric measurements. The influence of DNA immobilization conditions (pH value, concentration, incubation time, DNA immobilization procedure) were tested to choose the optimal assembly protocol. The SPCE/PDAP/DNA sensor was used for qualitative DNA damage discrimination by anticancer drugs in absence and in presence of copper ions. The wide range of anthracycline drugs (doxorubicin, daunorubicin, valrubicin, idarubicin, epirubicin, pirarubicin) and antimetabolite drug mitoxantrone were tested as intercalative agents. It has been shown that addition of mannitol as a radicals’ scavenger to the mixture of doxorubicin and copper ions neutralize the reactive oxygen species generated. The structure of drug, its intercalation ability and affinity to copper ions have affected the interaction with DNA. To evaluate the intercalation and concomitant secondary DNA damage by reactive oxygen species, two coefficients (Kint and KSD) was proposed. The sensor developed can be applied in the medical investigations of novel anticancer drugs.
- 25 June 2026
- Published by Ural Federal University in Chimica Techno Acta
- Vol. 13 (4) , 10223
Open AccessElectrochemical DNA sensor based on electropolymerized 2,3-diaminophenazine for detection of intercalative DNA damage in presence of copper ions
The electrochemical parameters of 2,3-diaminophenazine (DAP) and its polymeric form (PDAP) electrodeposited from the perchloric acid on the screen-printed carbon electrodes (SPCE) were investigated. The electropolymerized PDAP coating was used with native DNA from various sources (calf thymus, salmon sperm, herring sperm, chicken erythrocytes) for the DNA sensor assembly. The layer-by-layer assembly of the DNA sensor was controlled by voltammetric and impedimetric measurements. The influence of DNA immobilization conditions (pH value, concentration, incubation time, DNA immobilization procedure) were tested to choose the optimal assembly protocol. The SPCE/PDAP/DNA sensor was used for qualitative DNA damage discrimination by anticancer drugs in absence and in presence of copper ions. The wide range of anthracycline drugs (doxorubicin, daunorubicin, valrubicin, idarubicin, epirubicin, pirarubicin) and antimetabolite drug mitoxantrone were tested as intercalative agents. It has been shown that addition of mannitol as a radicals’ scavenger to the mixture of doxorubicin and copper ions neutralize the reactive oxygen species generated. The structure of drug, its intercalation ability and affinity to copper ions have affected the interaction with DNA. To evaluate the intercalation and concomitant secondary DNA damage by reactive oxygen species, two coefficients (Kint and KSD) was proposed. The sensor developed can be applied in the medical investigations of novel anticancer drugs.
- Open Access
- 21 June 2026
- Published by Ural Federal University in Chimica Techno Acta
- Vol. 13 (2)
Poly(Brilliant cresyl blue) as a perspective modifier for DNA sensors designed for DNA damage detection
The electrochemical characteristics of Brilliant cresyl blue and its polymeric form electrodeposited from the phosphate buffer on the screen-printed carbon electrodes (SPCE) were studied. It was shown by electrochemical quartz microbalance method that the frequency response gradually decreased with the number of electropolymerization cycles indicating the increasing mass of the polymeric product on the resonator surface. The poly(Brilliant cresyl blue) (PBCB) film was used along with native DNA from salmon sperm for the disposable DNA sensor assembly. The biocomponent immobilization strategies such as drying or incubation were tested to choose the optimal assembly protocol providing the greater response. The SPCE/PBCB/DNA sensor suggested was able to discriminate between various types of native and damaged DNA. Thermal denaturation, UV irradiation, ultrasound treatment and chemical oxidation by CuSO4 and H2O2 mixture were chosen as model DNA damaging agents. Finally, the sensor proposed was tested for the assessment of antioxidants protective effect of grapefruit, orange, lemon, bell pepper, red and yellow onion extracts. The pretreatment protocol was simple and can be widened for a greater range of the foods and beverages. The maximal protective effect was found for the lemon extract. The SPCE/PBCB/DNA sensor proposed can be applied in the ecological monitoring and food safety control.
- 21 June 2026
- Published by Ural Federal University in Chimica Techno Acta
- Vol. 13 (2)
Open AccessPoly(Brilliant cresyl blue) as a perspective modifier for DNA sensors designed for DNA damage detection
The electrochemical characteristics of Brilliant cresyl blue and its polymeric form electrodeposited from the phosphate buffer on the screen-printed carbon electrodes (SPCE) were studied. It was shown by electrochemical quartz microbalance method that the frequency response gradually decreased with the number of electropolymerization cycles indicating the increasing mass of the polymeric product on the resonator surface. The poly(Brilliant cresyl blue) (PBCB) film was used along with native DNA from salmon sperm for the disposable DNA sensor assembly. The biocomponent immobilization strategies such as drying or incubation were tested to choose the optimal assembly protocol providing the greater response. The SPCE/PBCB/DNA sensor suggested was able to discriminate between various types of native and damaged DNA. Thermal denaturation, UV irradiation, ultrasound treatment and chemical oxidation by CuSO4 and H2O2 mixture were chosen as model DNA damaging agents. Finally, the sensor proposed was tested for the assessment of antioxidants protective effect of grapefruit, orange, lemon, bell pepper, red and yellow onion extracts. The pretreatment protocol was simple and can be widened for a greater range of the foods and beverages. The maximal protective effect was found for the lemon extract. The SPCE/PBCB/DNA sensor proposed can be applied in the ecological monitoring and food safety control.
- Open Access
- 26 November 2025
- Published by Ural Federal University in Chimica Techno Acta
- Vol. 12 (4) , 9204
Voltammetric DNA sensor for the DNA damage detection based on poly(Methylene blue) electrodeposited from deep eutectic solvent
The features of Methylene blue electropolymerization from phosphate buffer and several deep eutectic solvents consisting of glucose and organic acid on the substrate of screen-printed carbon electrodes were studied. It was shown that the nature of the organic acid, which plays the role of hydrogen bond donor in deep eutectic solvent, affects the poly(Methylene blue) electropolymerization. The poly(Methylene blue) coating with the most prospective electrochemical characteristics was chosen for the DNA sensor assembly. The origin and molecular weight of DNA molecules had influence on the DNA sensor ability to discriminate the DNA damage from physical and chemical sources. The DNA sensor based on poly(Methylene blue) electrodeposited from the mixture of glucose and maleic acid and DNA from chicken erythrocytes was able to discriminate native, thermally denatured and chemically oxidized DNA. The DNA sensor based on poly(Methylene blue) and DNA from herring sperm was sensitive to the antioxidant addition. The sensors proposed can find the application in the medical investigations, food control, and environmental protection.
- 26 November 2025
- Published by Ural Federal University in Chimica Techno Acta
- Vol. 12 (4) , 9204
Open AccessVoltammetric DNA sensor for the DNA damage detection based on poly(Methylene blue) electrodeposited from deep eutectic solvent
The features of Methylene blue electropolymerization from phosphate buffer and several deep eutectic solvents consisting of glucose and organic acid on the substrate of screen-printed carbon electrodes were studied. It was shown that the nature of the organic acid, which plays the role of hydrogen bond donor in deep eutectic solvent, affects the poly(Methylene blue) electropolymerization. The poly(Methylene blue) coating with the most prospective electrochemical characteristics was chosen for the DNA sensor assembly. The origin and molecular weight of DNA molecules had influence on the DNA sensor ability to discriminate the DNA damage from physical and chemical sources. The DNA sensor based on poly(Methylene blue) electrodeposited from the mixture of glucose and maleic acid and DNA from chicken erythrocytes was able to discriminate native, thermally denatured and chemically oxidized DNA. The DNA sensor based on poly(Methylene blue) and DNA from herring sperm was sensitive to the antioxidant addition. The sensors proposed can find the application in the medical investigations, food control, and environmental protection.
- Open Access
- 3 November 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (11) , 735
Novel Nanocomposites of Carbon Nanomaterials and Poly(Neutral Red) Electropolymerized from Reline for DNA Damage Detection and Beverage Antioxidant Influence Assessment
Novel nanocomposites based on carbon black or multi-walled carbon nanotubes functionalized with carboxylic groups and Neutral red electropolymerized from reline were obtained in a one-step protocol and used for DNA biosensor development. The synthesis was carried out in potentiodynamic mode in a deep eutectic solvent reline consisting of a mixture of choline chloride and urea. The nanocomposite based on carbon black and poly(Neutral red) was applied for a voltammetric DNA biosensor developed to discriminate DNA damage. The sensor developed allowed the native, thermally denatured, and chemically oxidized DNA discrimination with either current changes or peak potential shifts. The nature of the DNA used had affected the sensor’s analytical response value. The DNA biosensor suggested was tested for the assessment of antioxidant capacity in such beverages as tea, coffee, white wine, and fruit-based drink purchased from local market. Simple, fast, and inexpensive approach of sensor modifying layer assembly would be demanded in control of food products and beverages quality, as well as for medical purposes.
- 3 November 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (11) , 735
Open AccessNovel Nanocomposites of Carbon Nanomaterials and Poly(Neutral Red) Electropolymerized from Reline for DNA Damage Detection and Beverage Antioxidant Influence Assessment
Novel nanocomposites based on carbon black or multi-walled carbon nanotubes functionalized with carboxylic groups and Neutral red electropolymerized from reline were obtained in a one-step protocol and used for DNA biosensor development. The synthesis was carried out in potentiodynamic mode in a deep eutectic solvent reline consisting of a mixture of choline chloride and urea. The nanocomposite based on carbon black and poly(Neutral red) was applied for a voltammetric DNA biosensor developed to discriminate DNA damage. The sensor developed allowed the native, thermally denatured, and chemically oxidized DNA discrimination with either current changes or peak potential shifts. The nature of the DNA used had affected the sensor’s analytical response value. The DNA biosensor suggested was tested for the assessment of antioxidant capacity in such beverages as tea, coffee, white wine, and fruit-based drink purchased from local market. Simple, fast, and inexpensive approach of sensor modifying layer assembly would be demanded in control of food products and beverages quality, as well as for medical purposes.
- 9 October 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (23) , 5286-5302
Pirarubicin determination with impedimetric and voltammetric DNA sensors based on poly(Nile Blue) electropolymerized from deep eutectic solvents
The phenoxazine dye Nile Blue electropolymerized from the deep eutectic solvents was used for the first time as a constituent of DNA sensors for voltammetric and impedimetric determination of the anthracycline medication pirarubicin.
- 9 October 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (23) , 5286-5302
Pirarubicin determination with impedimetric and voltammetric DNA sensors based on poly(Nile Blue) electropolymerized from deep eutectic solvents
The phenoxazine dye Nile Blue electropolymerized from the deep eutectic solvents was used for the first time as a constituent of DNA sensors for voltammetric and impedimetric determination of the anthracycline medication pirarubicin.
- Open Access
- 14 June 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (6) , 385
Impedimetric DNA Sensor Based on a Composite of Electrochemically Reduced Graphene Oxide and Polyproflavine Electropolymerized from Natural Deep Eutectic Solvent for Anthracycline Medications Determination
A novel nanocomposite based on electrochemically reduced graphene oxide (ERGO) and electropolymerized polyproflavine (PPFL) was obtained within a “one-pot” synthesis from natural deep eutectic solvent (NADES). NADES consisted of citric acid, glucose, and water in a molar ratio of 1:1:6. The synthesis was carried out in potentiostatic mode by consequent potential application in cathodic and anodic areas. The composite was applied to develop the impedimetric DNA sensor for anthracycline determination. The sensor has provided linear range from 10 nM to 0.1 mM for doxorubicin, from 1 pM to 10 nM for epirubicin, and from 10 pM to 10 nM for idarubicin, with the limit of detection 3 nM, 1 pM, and 5 pM, respectively. The concentrations of doxorubicin below 10 nM did not have any other influence on epirubicin and idarubicin determination despite their molecular structure similarity. The sensor developed was used for the determination of anticancer medications, such as doxorubicin, epirubicin, and idarubicin, in their standard solutions, pharmaceuticals, artificial, and human urine samples. It is worth noting that the additions of mannitol and lactose, which are the stabilizers of the pharmaceuticals, exhibited an interfering effect on the sensor response.
- 14 June 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (6) , 385
Open AccessImpedimetric DNA Sensor Based on a Composite of Electrochemically Reduced Graphene Oxide and Polyproflavine Electropolymerized from Natural Deep Eutectic Solvent for Anthracycline Medications Determination
A novel nanocomposite based on electrochemically reduced graphene oxide (ERGO) and electropolymerized polyproflavine (PPFL) was obtained within a “one-pot” synthesis from natural deep eutectic solvent (NADES). NADES consisted of citric acid, glucose, and water in a molar ratio of 1:1:6. The synthesis was carried out in potentiostatic mode by consequent potential application in cathodic and anodic areas. The composite was applied to develop the impedimetric DNA sensor for anthracycline determination. The sensor has provided linear range from 10 nM to 0.1 mM for doxorubicin, from 1 pM to 10 nM for epirubicin, and from 10 pM to 10 nM for idarubicin, with the limit of detection 3 nM, 1 pM, and 5 pM, respectively. The concentrations of doxorubicin below 10 nM did not have any other influence on epirubicin and idarubicin determination despite their molecular structure similarity. The sensor developed was used for the determination of anticancer medications, such as doxorubicin, epirubicin, and idarubicin, in their standard solutions, pharmaceuticals, artificial, and human urine samples. It is worth noting that the additions of mannitol and lactose, which are the stabilizers of the pharmaceuticals, exhibited an interfering effect on the sensor response.
- 27 November 2024
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 29 (5) , 1929-1943
Electrochemical characteristics of composites based on novel asymmetric pillar[5]arene with carbon materials and their potential electrochemical applications
- 27 November 2024
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 29 (5) , 1929-1943
Electrochemical characteristics of composites based on novel asymmetric pillar[5]arene with carbon materials and their potential electrochemical applications
- Open Access
- 9 February 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (2) , 93
Electrochemical Acetylcholinesterase Sensors for Anti-Alzheimer’s Disease Drug Determination
Neurodegenerative diseases and Alzheimer’s disease (AD), as one of the most common causes of dementia, result in progressive losses of cholinergic neurons and a reduction in the presynaptic markers of the cholinergic system. These consequences can be compensated by the inhibition of acetylcholinesterase (AChE) followed by a decrease in the rate of acetylcholine hydrolysis. For this reason, anticholinesterase drugs with reversible inhibition effects are applied for the administration of neurodegenerative diseases. Their overdosage, variation in efficiency and recommendation of an individual daily dose require simple and reliable measurement devices capable of the assessment of the drug concentration in biological fluids and medications. In this review, the performance of electrochemical biosensors utilizing immobilized cholinesterases is considered to show their advantages and drawbacks in the determination of anticholinesterase drugs. In addition, common drugs applied in treating neurodegenerative diseases are briefly characterized. The immobilization of enzymes, nature of the signal recorded and its dependence on the transducer modification are considered and the analytical characteristics of appropriate biosensors are summarized for donepezil, huperzine A, rivastigmine, eserine and galantamine as common anti-dementia drugs. Finally, the prospects for the application of AChE-based biosensors in clinical practice are discussed.
- 9 February 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (2) , 93
Open AccessElectrochemical Acetylcholinesterase Sensors for Anti-Alzheimer’s Disease Drug Determination
Neurodegenerative diseases and Alzheimer’s disease (AD), as one of the most common causes of dementia, result in progressive losses of cholinergic neurons and a reduction in the presynaptic markers of the cholinergic system. These consequences can be compensated by the inhibition of acetylcholinesterase (AChE) followed by a decrease in the rate of acetylcholine hydrolysis. For this reason, anticholinesterase drugs with reversible inhibition effects are applied for the administration of neurodegenerative diseases. Their overdosage, variation in efficiency and recommendation of an individual daily dose require simple and reliable measurement devices capable of the assessment of the drug concentration in biological fluids and medications. In this review, the performance of electrochemical biosensors utilizing immobilized cholinesterases is considered to show their advantages and drawbacks in the determination of anticholinesterase drugs. In addition, common drugs applied in treating neurodegenerative diseases are briefly characterized. The immobilization of enzymes, nature of the signal recorded and its dependence on the transducer modification are considered and the analytical characteristics of appropriate biosensors are summarized for donepezil, huperzine A, rivastigmine, eserine and galantamine as common anti-dementia drugs. Finally, the prospects for the application of AChE-based biosensors in clinical practice are discussed.
- Open Access
Electrochemical DNA-Sensor Based on Macrocyclic Dendrimers with Terminal Amino Groups and Carbon Nanomaterials
The assembling of thiacalix[4]arene-based dendrimers in cone, partial cone, and 1,3-alternate configuration on the surface of a glassy carbon electrode coated with carbon black or multiwalled carbon nanotubes has been characterized using cyclic voltammetry, electrochemical impedance spectroscopy, and scanning electron microscopy. Native and damaged DNA were electrostatically accumulated on the modifier layer. The influence of the charge of the redox indicator and of the macrocycle/DNA ratio was quantified and the roles of the electrostatic interactions and of the diffusional transfer of the redox indicator to the electrode interface indicator access were established. The developed DNA sensors were tested on discrimination of native, thermally denatured, and chemically damaged DNA and on the determination of doxorubicin as the model intercalator. The limit of detection of doxorubicin established for the biosensor based on multi-walled carbon nanotubes was equal to 1.0 pM with recovery from spiked human serum of 105–120%. After further optimization of the assembling directed towards the stabilization of the signal, the developed DNA sensors can find application in the preliminary screening of antitumor drugs and thermal damage of DNA. They can also be applied for testing potential drug/DNA nanocontainers as future delivery systems.
Open AccessElectrochemical DNA-Sensor Based on Macrocyclic Dendrimers with Terminal Amino Groups and Carbon Nanomaterials
The assembling of thiacalix[4]arene-based dendrimers in cone, partial cone, and 1,3-alternate configuration on the surface of a glassy carbon electrode coated with carbon black or multiwalled carbon nanotubes has been characterized using cyclic voltammetry, electrochemical impedance spectroscopy, and scanning electron microscopy. Native and damaged DNA were electrostatically accumulated on the modifier layer. The influence of the charge of the redox indicator and of the macrocycle/DNA ratio was quantified and the roles of the electrostatic interactions and of the diffusional transfer of the redox indicator to the electrode interface indicator access were established. The developed DNA sensors were tested on discrimination of native, thermally denatured, and chemically damaged DNA and on the determination of doxorubicin as the model intercalator. The limit of detection of doxorubicin established for the biosensor based on multi-walled carbon nanotubes was equal to 1.0 pM with recovery from spiked human serum of 105–120%. After further optimization of the assembling directed towards the stabilization of the signal, the developed DNA sensors can find application in the preliminary screening of antitumor drugs and thermal damage of DNA. They can also be applied for testing potential drug/DNA nanocontainers as future delivery systems.