Petra Reinhold
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Petra Reinhold has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Alisa Sergeeva
System Modeling Group, Institute for Veterinary Epidemiology and Biostatistics, Freie Universität Berlin, Königsweg 67, 10117 Berlin, Germany
1 shared publication - Bart Pardon
U Gent Calf Health, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
1 shared publication - Gundula Hoffmann
Department Sensors and Modelling, Leibniz Institute for Agricultural Engineering and Bioeconomy (ATB), 14469 Potsdam, Germany
1 shared publication - Hans-Jürgen Smith
Research in Respiratory Diagnostics, Bahrendorfer Straße 3A, 12555 Berlin, Germany
1 shared publication - Jade Bokma
Department of Internal Medicine, Reproduction, and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
1 shared publication - Lena Dißmann
Department Sensors and Modeling, Leibniz Institute for Agricultural Engineering and Bioeconomy (ATB), Max-Eyth-Allee 100, 14469 Potsdam, Germany
1 shared publication
Latest Publications
- Open Access
Evaluation of a Respiration Rate Sensor for Recording Tidal Volume in Calves under Field Conditions
In the assessment of pulmonary function in health and disease, both respiration rate (RR) and tidal volume (Vt) are fundamental parameters of spontaneous breathing. The aim of this study was to evaluate whether an RR sensor, which was previously developed for cattle, is suitable for additional measurements of Vt in calves. This new method would offer the opportunity to measure Vt continuously in freely moving animals. To measure Vt noninvasively, the application of a Lilly-type pneumotachograph implanted in the impulse oscillometry system (IOS) was used as the gold standard method. For this purpose, we applied both measuring devices in different orders successively, for 2 days on 10 healthy calves. However, the Vt equivalent (RR sensor) could not be converted into a true volume in mL or L. For a reliable recording of the Vt equivalent, a technical revision of the RR sensor excluding artifacts is required. In conclusion, converting the pressure signal of the RR sensor into a flow equivalent, and subsequently into a volume equivalent, by a comprehensive analysis, provides the basis for further improvement of the measuring system.
Open AccessEvaluation of a Respiration Rate Sensor for Recording Tidal Volume in Calves under Field Conditions
In the assessment of pulmonary function in health and disease, both respiration rate (RR) and tidal volume (Vt) are fundamental parameters of spontaneous breathing. The aim of this study was to evaluate whether an RR sensor, which was previously developed for cattle, is suitable for additional measurements of Vt in calves. This new method would offer the opportunity to measure Vt continuously in freely moving animals. To measure Vt noninvasively, the application of a Lilly-type pneumotachograph implanted in the impulse oscillometry system (IOS) was used as the gold standard method. For this purpose, we applied both measuring devices in different orders successively, for 2 days on 10 healthy calves. However, the Vt equivalent (RR sensor) could not be converted into a true volume in mL or L. For a reliable recording of the Vt equivalent, a technical revision of the RR sensor excluding artifacts is required. In conclusion, converting the pressure signal of the RR sensor into a flow equivalent, and subsequently into a volume equivalent, by a comprehensive analysis, provides the basis for further improvement of the measuring system.