Abhilash Krishnamurthy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abhilash Krishnamurthy has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Kristina Žagar Soderžnik
Department for Nanostructured Materials, Jožef Stefan Institute, Jamova Cesta 39, SI-1000 Ljubljana, Slovenia
3 shared publications Kristina Žagar Soderžnik
2 shared publicationsZoran Samardžija
Department for Nanostructured Materials, Jožef Stefan Institute, Jamova cesta 39, 1000 Ljubljana, Slovenia
2 shared publicationsAnja Korent
1 shared publication- Beno Klopčič
Department for Nanostructured Materials, Jožef Stefan Institute, Jamova c. 39, 1000 Ljubljana, Slovenia
1 shared publication - Igor Karlovits
Pulp and Paper Institute, Ljubljana, Slovenia
1 shared publication
Latest Publications
- Open Access
- 15 November 2025
- Published by Elsevier in Measurement
- Vol. 259
Frequency-domain analysis of voltammetric signals: a framework to augment electrochemical sensing explored through benzenediol detection
- 15 November 2025
- Published by Elsevier in Measurement
- Vol. 259
Open AccessFrequency-domain analysis of voltammetric signals: a framework to augment electrochemical sensing explored through benzenediol detection
- 26 May 2025
- Published by Association of Metallurgical Engineers of Serbia in Metallurgical & Materials Engineering Congress of South-East Europe
- Vol. 6 (1)
PORTABLE ELECTROCHEMICAL SENSORS FOR THE DETECTION OF PMT CHEMICALS IN REAL SAMPLES
Persistent, mobile, and toxic (PMT) chemicals pose a significant risk to water resources due to their resistance to biodegradation, ability to spread over long distances, and harmful effects on human health and the environment. Among the most widely detected PMT chemicals are bisphenols, benzisothiazolinone (BIT), and benzotriazole (BZT), which originate from common consumer and industrial products. Monitoring these chemicals is essential for assessing their impact and developing strategies for their reduction. Traditional detection methods like chromatography are effective but costly and time-consuming. Electrochemical sensors offer a promising alternative due to their affordability, portability, and high sensitivity. This study used carbon-based screen-printed electrodes (SPEs) to detect BPS and BIT, while SPEs modified with Vulcan carbon and polymer coatings were employed for BZT detection. Real samples, including parking ticket paper and river water, were analyzed to demonstrate the sensors' practical application. The findings highlight the potential of electrochemical sensors as efficient tools for on-site monitoring of PMT chmicals, contributing to improved environmental assessment and regulatory efforts.
- 26 May 2025
- Published by Association of Metallurgical Engineers of Serbia in Metallurgical & Materials Engineering Congress of South-East Europe
- Vol. 6 (1)
PORTABLE ELECTROCHEMICAL SENSORS FOR THE DETECTION OF PMT CHEMICALS IN REAL SAMPLES
Persistent, mobile, and toxic (PMT) chemicals pose a significant risk to water resources due to their resistance to biodegradation, ability to spread over long distances, and harmful effects on human health and the environment. Among the most widely detected PMT chemicals are bisphenols, benzisothiazolinone (BIT), and benzotriazole (BZT), which originate from common consumer and industrial products. Monitoring these chemicals is essential for assessing their impact and developing strategies for their reduction. Traditional detection methods like chromatography are effective but costly and time-consuming. Electrochemical sensors offer a promising alternative due to their affordability, portability, and high sensitivity. This study used carbon-based screen-printed electrodes (SPEs) to detect BPS and BIT, while SPEs modified with Vulcan carbon and polymer coatings were employed for BZT detection. Real samples, including parking ticket paper and river water, were analyzed to demonstrate the sensors' practical application. The findings highlight the potential of electrochemical sensors as efficient tools for on-site monitoring of PMT chmicals, contributing to improved environmental assessment and regulatory efforts.
- Open Access
Influence of Potentiostat Hardware on Electrochemical Measurements
We describe two operating modes for the same potentiostat, where the redox processes of hydroquinone in a hydrochloric acid medium are contrasted for cyclic voltammetry (CV) as functions of a digital/staircase scan and an analogue/linear scan. Although superficially there is not much to separate the two modes of operation as an end user, differences can be seen in the voltammograms while switching between the digital and analogue modes. The effects of quantization clearly have some impact on the measurements, with the outputs between the two modes being a function of the equivalent-circuit model of the electrochemical system under investigation. Increasing scan rates when using both modes produces higher peak redox currents, with the differences between the analogue and digital modes of operation being consistent as a function of the scan rate. Differences between the CV loops between the analogue and digital modes show key differences at certain points along the scans, which can be attributed to the nature of the electrolyte affecting the charging and discharging processes and consequently changing the peak currents of the redox processes. The faradaic processes were shown to be independent of the scan rates. Simulations of the equivalent-circuit behaviour show differences in the responses to different input signals, i.e., the step and ramp responses of the system. Both the voltage and current steps and ramp responses showed the time-domain behaviour of distinct elements of the equivalent electrochemical circuit model as an approximation of the applied digital and analogue CV input signals. Ultimately, it was concluded that similar parameters between the two modes of operation available with the potentiostat would lead to different output voltammograms and, despite advances in technology, digital systems can never fully emulate a true analogue system for electrochemical applications. These observations showcase the value of having hardware capable of true analogue characteristics over digital systems.
Open AccessInfluence of Potentiostat Hardware on Electrochemical Measurements
We describe two operating modes for the same potentiostat, where the redox processes of hydroquinone in a hydrochloric acid medium are contrasted for cyclic voltammetry (CV) as functions of a digital/staircase scan and an analogue/linear scan. Although superficially there is not much to separate the two modes of operation as an end user, differences can be seen in the voltammograms while switching between the digital and analogue modes. The effects of quantization clearly have some impact on the measurements, with the outputs between the two modes being a function of the equivalent-circuit model of the electrochemical system under investigation. Increasing scan rates when using both modes produces higher peak redox currents, with the differences between the analogue and digital modes of operation being consistent as a function of the scan rate. Differences between the CV loops between the analogue and digital modes show key differences at certain points along the scans, which can be attributed to the nature of the electrolyte affecting the charging and discharging processes and consequently changing the peak currents of the redox processes. The faradaic processes were shown to be independent of the scan rates. Simulations of the equivalent-circuit behaviour show differences in the responses to different input signals, i.e., the step and ramp responses of the system. Both the voltage and current steps and ramp responses showed the time-domain behaviour of distinct elements of the equivalent electrochemical circuit model as an approximation of the applied digital and analogue CV input signals. Ultimately, it was concluded that similar parameters between the two modes of operation available with the potentiostat would lead to different output voltammograms and, despite advances in technology, digital systems can never fully emulate a true analogue system for electrochemical applications. These observations showcase the value of having hardware capable of true analogue characteristics over digital systems.
- Open Access
- 10 May 2024
- Published by Elsevier in Electrochimica Acta
- Vol. 493
Electrochemical detection of benzenediols using carbon-supported catalysts
- 10 May 2024
- Published by Elsevier in Electrochimica Acta
- Vol. 493
Open AccessElectrochemical detection of benzenediols using carbon-supported catalysts
- Open Access
IoT Electrochemical Sensor with Integrated Ni(OH)2–Ni Nanowires for Detecting Formaldehyde in Tap Water
Simple, low-cost methods for sensing volatile organic compounds that leave no trace and do not have a detrimental effect on the environment are able to protect communities from the impacts of contaminants in water supplies. This paper reports the development of a portable, autonomous, Internet of Things (IoT) electrochemical sensor for detecting formaldehyde in tap water. The sensor is assembled from electronics, i.e., a custom-designed sensor platform and developed HCHO detection system based on Ni(OH)2–Ni nanowires (NWs) and synthetic-paper-based, screen-printed electrodes (pSPEs). The sensor platform, consisting of the IoT technology, a Wi-Fi communication system, and a miniaturized potentiostat can be easily connected to the Ni(OH)2–Ni NWs and pSPEs via a three-terminal electrode. The custom-made sensor, which has a detection capability of 0.8 µM/24 ppb, was tested for an amperometric determination of the HCHO in deionized (DI) and tap-water-based alkaline electrolytes. This promising concept of an electrochemical IoT sensor that is easy to operate, rapid, and affordable (it is considerably cheaper than any lab-grade potentiostat) could lead to the straightforward detection of HCHO in tap water.
Open AccessIoT Electrochemical Sensor with Integrated Ni(OH)2–Ni Nanowires for Detecting Formaldehyde in Tap Water
Simple, low-cost methods for sensing volatile organic compounds that leave no trace and do not have a detrimental effect on the environment are able to protect communities from the impacts of contaminants in water supplies. This paper reports the development of a portable, autonomous, Internet of Things (IoT) electrochemical sensor for detecting formaldehyde in tap water. The sensor is assembled from electronics, i.e., a custom-designed sensor platform and developed HCHO detection system based on Ni(OH)2–Ni nanowires (NWs) and synthetic-paper-based, screen-printed electrodes (pSPEs). The sensor platform, consisting of the IoT technology, a Wi-Fi communication system, and a miniaturized potentiostat can be easily connected to the Ni(OH)2–Ni NWs and pSPEs via a three-terminal electrode. The custom-made sensor, which has a detection capability of 0.8 µM/24 ppb, was tested for an amperometric determination of the HCHO in deionized (DI) and tap-water-based alkaline electrolytes. This promising concept of an electrochemical IoT sensor that is easy to operate, rapid, and affordable (it is considerably cheaper than any lab-grade potentiostat) could lead to the straightforward detection of HCHO in tap water.