Franz Kohl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Franz Kohl has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Almir Talic
Institute of Computer Technology, Vienna University of Technology, Gußhausstraße 27-29, A-1040 Vienna, Austria
1 shared publication - Franz Keplinger
Institute of Sensor and Actuator Systems, Vienna University of Technology, Gusshausstraße 27-29, A-1040 Vienna, Austria
1 shared publication - Roman Beigelbeck
Department für Integrierte Sensorsysteme, Universität für Weiterbildung Krems, Wiener Neustadt, Österreich
1 shared publication - Samir Cerimovic
Institute of Computer Technology, Vienna University of Technology, Gußhausstraße 27-29, A-1040 Vienna, Austria
1 shared publication - Thilo Sauter
Institute of Computer Technology, TU Wien, Vienna, Austria
1 shared publication
Latest Publications
- Open Access
The Impact of Surface Discontinuities on MEMS Thermal Wind Sensor Accuracy
A 2D calorimetric flow transducer is used to study distortions of the flow velocity field induced by small surface discontinuities around the chip. The transducer is incorporated into a matching recess of a PCB enabling wire-bonded interconnections to the transducer. The chip mount forms one wall of a rectangular duct. Two shallow recesses at opposite edges of the transducer chip are required for wired interconnections. They distort the flow velocity field inside the duct and deteriorate the flow setting precision. In-depth 3D-FEM analyses of the setup revealed that both the local flow direction as well as the surface-near distribution of the flow velocity magnitude deviate significantly from the ideal guided flow case. With a temporary leveling of the indentations, the impact of the surface imperfections could be largely suppressed. Including a yaw setting uncertainty of about ±0.5°, a peak-to-peak deviation of 3.8° of the transducer output from the intended flow direction was achieved with a mean flow velocity of 5 m/s in the duct corresponding to a shear rate of 2.4·104 s−1 at the chip surface. In view of the practical compromises, the measured deviation compares well with the peak-to-peak value of 1.74° predicted by previous simulations.
Open AccessThe Impact of Surface Discontinuities on MEMS Thermal Wind Sensor Accuracy
A 2D calorimetric flow transducer is used to study distortions of the flow velocity field induced by small surface discontinuities around the chip. The transducer is incorporated into a matching recess of a PCB enabling wire-bonded interconnections to the transducer. The chip mount forms one wall of a rectangular duct. Two shallow recesses at opposite edges of the transducer chip are required for wired interconnections. They distort the flow velocity field inside the duct and deteriorate the flow setting precision. In-depth 3D-FEM analyses of the setup revealed that both the local flow direction as well as the surface-near distribution of the flow velocity magnitude deviate significantly from the ideal guided flow case. With a temporary leveling of the indentations, the impact of the surface imperfections could be largely suppressed. Including a yaw setting uncertainty of about ±0.5°, a peak-to-peak deviation of 3.8° of the transducer output from the intended flow direction was achieved with a mean flow velocity of 5 m/s in the duct corresponding to a shear rate of 2.4·104 s−1 at the chip surface. In view of the practical compromises, the measured deviation compares well with the peak-to-peak value of 1.74° predicted by previous simulations.