Mingyu Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mingyu Wang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Hua-Wei Ji
School of Mechanical Engineering, Hangzhou Dianzi University, Hangzhou, China
2 shared publications - Ying Chen
Institute of Flexible Electronics Technology of THU
2 shared publications - Hong Zou
School of Mechanical Engineering, Hangzhou Dianzi University, Hangzhou 310018, China
1 shared publication Honglei Zhou
AML, Department of Engineering Mechanics, Center for Flexible Electronics Technology, Tsinghua University, Beijing, China
1 shared publication- Jun Ai
Jiaxing Key Laboratory of Flexible Electronics Based Intelligent Sensing and Advanced Manufacturing Technology, Institute of Flexible Electronics Technology of Tsinghua University, Jiaxing 314000, China
1 shared publication Kai Pang
Department of Polymer Science and Engineering, MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Zhejiang University, Hangzhou, China
1 shared publication
Latest Publications
- Open Access
- 17 October 2023
- Published by Springer Nature in npj Flexible Electronics
- Vol. 7 (1) , 1-10
Skin-integrated, biocompatible, and stretchable silicon microneedle electrode for long-term EMG monitoring in motion scenario
Electromyography (EMG) signal is the electrical potential generated by contracting muscle cells. Long-term and accurate EMG monitoring is desirable for neuromuscular function assessment in clinical and the human–computer interfaces. Herein, we report a skin-integrated, biocompatible, and stretchable silicon microneedle electrode (SSME) inspired by the plant thorns. The silicon microneedles are half encapsulated by the polyimide (PI) to enhance the adaptability to deformation and resistance to fatigue. Thorn-like SSME is realized by the semi-additive method with a stretchability of not less than 36%. The biocompatibility of SSME has been verified using cytotoxicity tests. EMG monitoring in motion and long-term has been conducted to demonstrate the feasibility and performance of the SSME, which is compared with a commercial wet electrode. Hopefully, the strategies reported here can lead to accurate and long-term EMG monitoring, facilitating an effective and reliable human–computer interface.
- 17 October 2023
- Published by Springer Nature in npj Flexible Electronics
- Vol. 7 (1) , 1-10
Open AccessSkin-integrated, biocompatible, and stretchable silicon microneedle electrode for long-term EMG monitoring in motion scenario
Electromyography (EMG) signal is the electrical potential generated by contracting muscle cells. Long-term and accurate EMG monitoring is desirable for neuromuscular function assessment in clinical and the human–computer interfaces. Herein, we report a skin-integrated, biocompatible, and stretchable silicon microneedle electrode (SSME) inspired by the plant thorns. The silicon microneedles are half encapsulated by the polyimide (PI) to enhance the adaptability to deformation and resistance to fatigue. Thorn-like SSME is realized by the semi-additive method with a stretchability of not less than 36%. The biocompatibility of SSME has been verified using cytotoxicity tests. EMG monitoring in motion and long-term has been conducted to demonstrate the feasibility and performance of the SSME, which is compared with a commercial wet electrode. Hopefully, the strategies reported here can lead to accurate and long-term EMG monitoring, facilitating an effective and reliable human–computer interface.
- Open Access
- 31 October 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (11) , 944
A Flexible Optoelectronic Device for Continuous Cerebral Blood Flow Monitoring
Human cerebral oxygenation and hemodynamics can be estimated by cerebral oxygenation parameters. Functional near-infrared spectroscopy (fNIRS) can be used to measure the hemoglobin concentration index of brain tissue noninvasively and in real time. However, limited by cumbersome equipment, high price and uncomfortable wear, conventional fNIRS monitoring systems still cannot achieve continuous and long-term monitoring. In this work, a flexible and wearable long-term monitoring system is developed featured with cost efficiency, simple preparation and light weight (only 1.6 g), which consists of a pair of light-emitting diodes (LEDs) and a photodetector (PD). Triangular serpentine interconnectors are introduced to connect the functional elements, enabling the device to be stretched in multiple directions. The device can continuously work for 7 h and be subjected to 2000 cycles of bending loading, with less than 3% change in voltage value, 1.89% and 1.9% change in LED luminous power and 0.9% change in voltage value. Furthermore, the hand-gripping and breath-holding experiments show that the system can accurately measure the changes in hemoglobin concentration in accordance with the commercial device. The flexible fNIRS system presented here not only provides a simple preparation process but also offers new ideas for daily cerebral state monitoring and prolonged clinical monitoring.
- 31 October 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (11) , 944
Open AccessA Flexible Optoelectronic Device for Continuous Cerebral Blood Flow Monitoring
Human cerebral oxygenation and hemodynamics can be estimated by cerebral oxygenation parameters. Functional near-infrared spectroscopy (fNIRS) can be used to measure the hemoglobin concentration index of brain tissue noninvasively and in real time. However, limited by cumbersome equipment, high price and uncomfortable wear, conventional fNIRS monitoring systems still cannot achieve continuous and long-term monitoring. In this work, a flexible and wearable long-term monitoring system is developed featured with cost efficiency, simple preparation and light weight (only 1.6 g), which consists of a pair of light-emitting diodes (LEDs) and a photodetector (PD). Triangular serpentine interconnectors are introduced to connect the functional elements, enabling the device to be stretched in multiple directions. The device can continuously work for 7 h and be subjected to 2000 cycles of bending loading, with less than 3% change in voltage value, 1.89% and 1.9% change in LED luminous power and 0.9% change in voltage value. Furthermore, the hand-gripping and breath-holding experiments show that the system can accurately measure the changes in hemoglobin concentration in accordance with the commercial device. The flexible fNIRS system presented here not only provides a simple preparation process but also offers new ideas for daily cerebral state monitoring and prolonged clinical monitoring.
- 18 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (9) , 10483-10490
A Flexible Dual-Modal Sensing System for Synchronous Pressure and Inertial Monitoring of Finger Movement
In this paper, a flexible dual-modal sensing system is proposed for monitoring the pressure and inertial information of the finger movement. The sensing system is composed of a pressure sensor array and two inertial measurement units (IMUs) for sensing the fingertip pressure and the finger gesture, respectively. The graphene aerogel (GA) with excellent sensitivity is utilized as the sensing element of the pressure sensor array, and five GA sensing elements are designed to detect the pressure distribution of different fingertip areas. With serpentine circuitry structure sealed by polydimethylsiloxane (PDMS), the pressure sensor array can demonstrate flexibility, stretchability, and biocompatibility when mounted on the finger. The two IMUs are attached to the back of the finger. The signal and power supply electrodes of the pressure sensor array are connected with the IMUs, which can obtain the pressure and inertial signals simultaneously. A prototype was fabricated and experiments were carried out to test the basic performance of the sensing system. It has been verified that the pressure sensor array shows high resolution of 108.8 kPa and well stability after a 10-hour repeatability experiment. The IMUs are also reliable for sensing inertial information after calibration. Measurement of four daily hand movements and recognition of ten typical grasping gestures were conducted to verify the feasibility of the proposed system. Experimental results showed that the sensing systems could classify the ten gestures with a high accuracy of 97%, which verified the approach can provide a promising path for hand movement measurement and gesture recognition.
- 18 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (9) , 10483-10490
A Flexible Dual-Modal Sensing System for Synchronous Pressure and Inertial Monitoring of Finger Movement
In this paper, a flexible dual-modal sensing system is proposed for monitoring the pressure and inertial information of the finger movement. The sensing system is composed of a pressure sensor array and two inertial measurement units (IMUs) for sensing the fingertip pressure and the finger gesture, respectively. The graphene aerogel (GA) with excellent sensitivity is utilized as the sensing element of the pressure sensor array, and five GA sensing elements are designed to detect the pressure distribution of different fingertip areas. With serpentine circuitry structure sealed by polydimethylsiloxane (PDMS), the pressure sensor array can demonstrate flexibility, stretchability, and biocompatibility when mounted on the finger. The two IMUs are attached to the back of the finger. The signal and power supply electrodes of the pressure sensor array are connected with the IMUs, which can obtain the pressure and inertial signals simultaneously. A prototype was fabricated and experiments were carried out to test the basic performance of the sensing system. It has been verified that the pressure sensor array shows high resolution of 108.8 kPa and well stability after a 10-hour repeatability experiment. The IMUs are also reliable for sensing inertial information after calibration. Measurement of four daily hand movements and recognition of ten typical grasping gestures were conducted to verify the feasibility of the proposed system. Experimental results showed that the sensing systems could classify the ten gestures with a high accuracy of 97%, which verified the approach can provide a promising path for hand movement measurement and gesture recognition.