QLQinghui Liu

Qinghui Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qinghui Liu has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Shanghai Tianma Radio Telescope and Its Role in Pulsar Astronomy

    by Zhen Yan, Zhiqiang Shen, Yajun Wu, Rongbing Zhao, Jie Liu, Zhipeng Huang, Rui Wang, Xiaowei Wang, Qinghui Liu, Bin Li, et al.

    After two phases of on-site construction and testing (2010–2013 and 2013–2017), the Shanghai Tianma Radio Telescope (TMRT) can work well, with efficiencies better than 50% from 1.3 to 50.0 GHz, mainly benefiting from its low-noise cryogenic receivers and active surface system. Pulsars were chosen as important targets of research at the TMRT because of their important scientific and applied values. To meet the demands of pulsar-related observations, TMRT is equipped with some necessary backends, including a digital backend system (DIBAS) supporting normal pulsar observation modes, a real-time fast-radio-burst-monitoring backend, and baseband backends for very-long-baseline interferometry (VLBI) observations. Utilizing its high sensitivity and simultaneous dual-frequency observation capacity, a sequence of pulsar research endeavors has been undertaken, such as long-term pulsar timing, magnetar monitoring, multi-frequency (or high-frequency) observations, interstellar scintillation, pulsar VLBI, etc. In this paper, we give a short introduction about pulsar observation systems at the TMRT and briefly review the results obtained by these pulsar research projects.


  • Open Access

    Application of the Tianwen-1 DOR Signals Observed by Very Long Baseline Interferometry Radio Telescopes in the Study of Solar Wind Plasma and a Coronal Mass Ejection

    by Zhichao Wang, Maoli Ma, Qinghui Liu, Qingbao He, Xin Zheng, Lijia Liu, Guifré Molera Calvés

    The Tianwen-1 (TW1) Mars probe experienced solar conjunction for the first time in 2021. The China VLBI Network (CVN) observes the differential one-way ranging (DOR) signals of TW1 throughout its phase. This paper explores the application of CVN observation data to study the solar wind plasma. First, the frequency and phase of the DOR carrier and sidetones at each station are calculated using the Doppler method. Then, the variations in both the differential phase delays (DPD) and the total electron content (TEC) are calculated using the phase of the sidetones. We also statistically analyze the fluctuations in the Delta-DOR (ΔDOR) group delay. The results indicate that the fluctuations of the frequency, phase, ΔDOR group delay, delay rate, and TEC variations of the TW1 signals increase with the decrease of the heliocentric distance. On 2021 November 2, a coronal mass ejection (CME) passed across the ray paths of the telescope beams, when the heliocentric distance and heliographic latitude of the projected position of Mars were 30.6 Rs and 3°, respectively. Our data catch the impact of the CME on the DOR signals. The change of the DPD reaches 170 ps, which is equivalent to 986 TECU. We utilize the cross correlation to analyze the frequency fluctuations at multiple stations, and obtain the propagation direction and velocity variations of the CME. Our analysis indicates that multifrequency DOR signals observed by very long baseline interferometry stations have great application to characterize the electron density variations and propagation of the solar wind plasma.


  • A novel high precision Doppler frequency estimation method based on the third-order phase-locked loop

    by Tao Deng, Mao-Li Ma, Qing-Hui Liu, Ya-Jun Wu

    In deep space exploration, many engineering and scientific requirements require the accuracy of the measured Doppler frequency to be as high as possible. In our paper, we analyze the possible frequency measurement points of the third-order phase-locked loop (PLL) and find a new Doppler measurement strategy. Based on this finding, a Doppler frequency measurement algorithm with significantly higher measurement accuracy is obtained. In the actual data processing, compared with the existing engineering software, the accuracy of frequency of 1 second integration is about 5.5 times higher when using the new algorithm. The improved algorithm is simple and easy to implement. This improvement can be easily combined with other improvement methods of PLL, so that the performance of PLL can be further improved.


  • A novel Doppler frequency measurement method based on the closed-loop signal correlation for deep space exploration

    by Tao Deng, Mao-Li Ma, Qing-Bao He, Qing-Hui Liu, Ya-Jun Wu, Xin Zheng

    In deep space exploration, it is necessary to improve the accuracy of frequency measurement to meet the requirements of precise orbit determination and various scientific studies. A phase detector is one of the key modules that restricts the tracking performance of phase-locked loop (PLL). Based on the phase relationship between adjacent signals in the time domain, a novel phase detector is presented to replace the arctangent phase detector. The new PLL, which is a closed loop signal correlation algorithm, shows good performance in tracking signals with high precision and the tracking accuracy of frequency of 1 second integration is close to Cramer-Rao lower bound (CRLB) when setting proper parameters. Actual data processing results further illustrate the excellent performance of the novel PLL.


  • Open Access

    High‐Precision Carrier Tracking Algorithm for Extremely Weak and High‐Dynamic Signals

    by Tao Deng, Maoli Ma, Qinghui Liu, Yajun Wu

    Obtaining high‐precision Doppler frequencies for very weak and high‐dynamic signals in deep space exploration is challenging. Such signals are commonly encountered, including in soft landing of lunar probes and the entry, descent, and landing (EDL) phase of Mars probes. Phase‐locked loop (PLL) is a widely used method for measuring high‐precision Doppler frequencies. In this study, two major improvements are applied to PLL. The first is that high precision estimation of initial frequency is achieved by open loop maximum amplitude search algorithm. Second, a novel denoising method is proposed and a new type of phase detector is designed based on this new denoising method. By replacing arctangent phase detector with the novel phase detector, the tracking accuracy and weak‐signal tracking abilities of the PLL are improved. The actual data processing results of soft landing process of lunar probe further verify the excellent performance of the improved PLL.