EJEric E. Johnson

Eric E. Johnson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Eric E. Johnson has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dual Versus Single-Plate Fixation of Midshaft Clavicular Fractures

    by J. Benjamin Allis, Edward C. Cheung, Eric D. Farrell, Eric E. Johnson, Devon M. Jeffcoat

    Background: Implant-related symptoms are the most common reason for reoperation after open reduction and internal fixation (ORIF) of midshaft clavicular fractures. Dual mini-fragment plate fixation is a relatively new solution that may decrease implant prominence while maintaining fixation strength and function. There are minimal published data comparing reoperation rates and clinical outcomes between single, superior-plate constructs and dual mini-fragment plate constructs in the fixation of midshaft clavicular fractures. We hypothesized that reducing plate size with the use of dual mini-fragment plating compared with standard, 3.5-mm, superior plating would minimize implant symptoms and the corresponding need for reoperation while still providing sufficient fixation to allow fracture-healing and return to function. Methods: We retrospectively reviewed the cases of 44 consecutive patients who underwent ORIF of displaced midshaft clavicular fractures utilizing either a single, 3.5-mm, superior plate construct (21 patients) or a dual, 2.7-mm and 2.4-mm, plate construct (23 patients). Outcomes at a minimum of 2 years were assessed. Primary outcome measures included reoperation for any reason and the American Shoulder and Elbow Surgeons (ASES) Standardized Shoulder Assessment Form, patient self-report section. Results: There was a 100% union rate in both groups. None (0%) of the 23 patients who received the dual (2.7-mm and 2.4-mm) plate construct and 6 (29%) of the 21 patients who received the single (3.5-mm) plate construct underwent reoperation for implant-related symptoms. Using a Fisher exact test, the rate of reoperation was compared between the groups, and the difference was found to be significant (p = 0.008). Using an unpaired t test, the difference in mean ASES scores was not significant (p = 0.138) between the dual-plate group (98 of 100) and the single superior plate group (96 of 100) with retained implants. Conclusions: In our comparative retrospective series, dual fixation utilizing a 2.7-mm superior plate and a 2.4-mm anterior plate for the treatment of displaced midshaft clavicular fractures was associated with a significantly lower rate of reoperation when compared with single, 3.5-mm, superior plate fixation. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


  • An Early Look at Operative Orthopaedic Injuries Associated with Electric Scooter Accidents

    by Chad R. Ishmael, Peter P. Hsiue, Stephen D. Zoller, Pengcheng Wang, Kellyn R. Hori, Jonathan D. Gatto, Rebecca Li, Devon M. Jeffcoat, Eric E. Johnson, Nicholas M. Bernthal

    Background: There is a new method of transportation that started in our community in late 2017— rideshare electric scooters (e-scooters). These scooters have proven immensely popular and can now be found in many cities around the world. Despite the pervasiveness of e-scooters, their associated injury patterns are poorly understood. The purpose of this study was to describe our department’s experience at the epicenter of the e-scooter phenomenon that is sweeping the globe and to characterize operative orthopaedic injuries that are related to e-scooter accidents. Methods: We performed a retrospective chart review of all of the operative orthopaedic cases and trauma consults at 2 trauma centers (a level-I center and a level-II center) between September 2017 and August 2019. We identified all operative injuries in which the cause of injury was an e-scooter accident. Data that included demographics, mechanism of injury, diagnosis, and treatment were collected. Results: Seventy-five operative injuries were identified in 73 patients during the study period. The mean patient age was 35.4 years (range, 14 to 74 years), and the median age was 32 years. There were 4 pediatric patients (14, 15, 15, and 17 years old). Thirty-two patients (43.8%) sustained upper-extremity injuries, and 42 patients (57.5%) sustained lower-extremity injuries; 1 of these patients had both upper and lower-extremity injuries. Nine patients (12.3%) had open fractures. There were 7 hip fractures in patients with an average age of 42.4 years (range, 28 to 68 years). Seventy-one (97.3%) of 73 patients were e-scooter riders, and 2 (2.7%) were pedestrians who were struck by e-scooter riders. Conclusions: E-scooters can cause serious injury. Seventy-three patients required operative treatment in just the first 2 years of e-scooter use in our community. Operative injuries occurred throughout the skeletal system, and several were injuries that are typically associated with high-energy trauma. Although, as a rule, e-scooter use is limited to adults and banned in high pedestrian-traffic areas in our city, the inclusion of 4 underage riders and 2 pedestrians in our cohort suggests that these rules are not always followed. As e-scooters continue to increase in popularity, additional steps should be taken to regulate their use and protect riders and the public.