Geoffrey S. Baer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Geoffrey S. Baer has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- David Marcu
Sauk Prairie Memorial Hospital, Prairie du Sac, Wiscosin, United States
3 shared publications - Ray Vanderby
Department of Orthopedics and Rehabilitation, University of Wisconsin, Madison, Wisconsin, USA
3 shared publications - Brian E. Walczak
Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, Wisconsin
2 shared publications - Darryl G. Thelen
Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, USA; Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI, USA; Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, WI, USA
2 shared publications - Kayt E. Frisch
Dordt College Department of Engineering, Sioux Center, Iowa, USA
2 shared publications Abbey DeBruin
UW Health, University of Wisconsin
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by SAGE Publications in Video Journal of Sports Medicine
- Vol. 6 (1)
Tibial Tubercle Osteotomy With Medial Patellofemoral Ligament Reconstruction Utilizing Autograft Hamstring Tendon and Knotless Suture Anchor Fixation
Background: Recurrent patellar instability is defined as ≥2 dislocation events or recurrence after surgical treatment. Surgical intervention is aimed at correcting pathoanatomic abnormalities. A tibial tubercle osteotomy (TTO) is an intervention that corrects patients with high tibial tuberosity-trochlear groove (TT-TG) distances and/or patella alta as measured by increased Caton-Deschamps index (CDI). Anteromedialization osteotomies improve abnormal TT-TG distances and offload the patellofemoral joint in patients with chondral lesions. Distalization can be utilized to correct patella alta and can be combined with anteromedialization osteotomies. We present a technique for TTO with medial patellofemoral ligament (MPFL) reconstruction (MPFLR) utilizing autograft gracilis tendon and knotless suture anchor fixation. Indications: Indications for a TTO with MPFLR include patients with recurrent patellar instability and increased TT-TG distance and/or increased CDI indicative of patella alta. Technique Description: Diagnostic arthroscopic examination of the knee is performed to assess chondral lesions of the patellofemoral joint. An anteromedial approach to the tibia is performed. The harvest of the autograft gracilis tendon is completed. TTO is performed based on the results of the preoperative examination and planning. Fixation is provided by two 4.5-mm stainless steel, solid screws in lag-by-technique mode. Two 1.4-mm knotless, all-suture anchors are then placed at the superomedial and midpoint of the patella after the approach. Schottle’s point is identified, and a tunnel is drilled for graft placement. The 2 limbs of the graft are passed between layers 2 and 3 after fixation. An interference screw is used for graft fixation within the tunnel. A repeat examination is performed to confirm patellar stability, and the incisions are then closed. Results: All-suture, knotless fixation of MPFL grafts has been shown in biomechanical studies to perform as well as knotted and knotless solid suture anchors when compared with overall load to failure and resistance to cyclic creep. The use of autograft hamstring in adolescents undergoing MPFLR shows no difference when compared with allograft. Discussion/Conclusion: Utilization of knotless all-suture anchors with autograft hamstring tendon in MPFLR with TTO presents an alternative to surgical fixation in patients with recurrent patellar instability. Patient Consent Disclosure Statement: The author(s) attests that consent has been obtained from any patient(s) appearing in this publication. If the individual may be identifiable, the author(s) has included a statement of release or other written form of approval from the patient(s) with this submission for publication.
- 1 January 2026
- Published by SAGE Publications in Video Journal of Sports Medicine
- Vol. 6 (1)
Open AccessTibial Tubercle Osteotomy With Medial Patellofemoral Ligament Reconstruction Utilizing Autograft Hamstring Tendon and Knotless Suture Anchor Fixation
Background: Recurrent patellar instability is defined as ≥2 dislocation events or recurrence after surgical treatment. Surgical intervention is aimed at correcting pathoanatomic abnormalities. A tibial tubercle osteotomy (TTO) is an intervention that corrects patients with high tibial tuberosity-trochlear groove (TT-TG) distances and/or patella alta as measured by increased Caton-Deschamps index (CDI). Anteromedialization osteotomies improve abnormal TT-TG distances and offload the patellofemoral joint in patients with chondral lesions. Distalization can be utilized to correct patella alta and can be combined with anteromedialization osteotomies. We present a technique for TTO with medial patellofemoral ligament (MPFL) reconstruction (MPFLR) utilizing autograft gracilis tendon and knotless suture anchor fixation. Indications: Indications for a TTO with MPFLR include patients with recurrent patellar instability and increased TT-TG distance and/or increased CDI indicative of patella alta. Technique Description: Diagnostic arthroscopic examination of the knee is performed to assess chondral lesions of the patellofemoral joint. An anteromedial approach to the tibia is performed. The harvest of the autograft gracilis tendon is completed. TTO is performed based on the results of the preoperative examination and planning. Fixation is provided by two 4.5-mm stainless steel, solid screws in lag-by-technique mode. Two 1.4-mm knotless, all-suture anchors are then placed at the superomedial and midpoint of the patella after the approach. Schottle’s point is identified, and a tunnel is drilled for graft placement. The 2 limbs of the graft are passed between layers 2 and 3 after fixation. An interference screw is used for graft fixation within the tunnel. A repeat examination is performed to confirm patellar stability, and the incisions are then closed. Results: All-suture, knotless fixation of MPFL grafts has been shown in biomechanical studies to perform as well as knotted and knotless solid suture anchors when compared with overall load to failure and resistance to cyclic creep. The use of autograft hamstring in adolescents undergoing MPFLR shows no difference when compared with allograft. Discussion/Conclusion: Utilization of knotless all-suture anchors with autograft hamstring tendon in MPFLR with TTO presents an alternative to surgical fixation in patients with recurrent patellar instability. Patient Consent Disclosure Statement: The author(s) attests that consent has been obtained from any patient(s) appearing in this publication. If the individual may be identifiable, the author(s) has included a statement of release or other written form of approval from the patient(s) with this submission for publication.
- Open Access
- 1 January 2023
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 8 (1)
Effects of General Anesthesia Plus Multimodal Analgesia on Immediate Perioperative Outcomes of Hamstring Tendon Autograft ACL Reconstruction
Background: Anterior cruciate ligament reconstruction with hamstring tendon autograft (H-ACLR) is a standard ambulatory procedure with the potential for considerable postoperative pain. We hypothesized that general anesthesia combined with a multimodal analgesia regimen would reduce postoperative opioid use associated with H-ACLR.Methods: This study was a single-center, surgeon-stratified, double-blinded, placebo-controlled, randomized clinical trial. The primary end point was the total postoperative opioid use during the immediate postoperative period, and secondary outcomes included postoperative knee pain, adverse events, and ambulatory discharge efficiency.Results: One hundred and twelve subjects, 18 to 52 years of age, were randomized to placebo (57 subjects) or combination multimodal analgesia (MA) (55 subjects). The MA group required fewer opioids postoperatively (mean ± standard deviation, 9.81 ± 7.58 versus 13.88 ± 8.49 morphine milligram equivalents; p = 0.010; effect size = −0.51). Similarly, the MA group required fewer opioids within the first 24 hours postoperatively (mean ± standard deviation, 16.56 ± 10.77 versus 22.13 ± 10.66 morphine milligram equivalents; p = 0.008; effect size = −0.52). The subjects in the MA group reported lower posteromedial knee pain (median [interquartile range, IQR]: 3.0 [0.0 to 5.0] versus 4.0 [2.0 to 5.0]; p = 0.027) at 1 hour postoperatively. Nausea medication was required for 10.5% of the subjects receiving the placebo versus 14.5% of the subjects receiving MA (p = 0.577). Pruritis was reported for 17.5% of subjects receiving the placebo versus 14.5% receiving MA (p = 0.798). The median time to discharge was 177 minutes (IQR, 150.5 to 201.0 minutes) for subjects receiving placebo versus 188 minutes (IQR, 160.0 to 222.0 minutes) for those receiving MA (p = 0.271).Conclusions: A combination of general anesthesia and local, regional, oral, and intravenous multimodal analgesia appears to reduce postoperative opioid requirements after H-ACLR compared with placebo. Adding preoperative patient education and focusing on donor-site analgesia may maximize perioperative outcomes.Level of Evidence: TherapeuticLevel I. See Instructions for Authors for a complete description of levels of evidence.
- 1 January 2023
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 8 (1)
Open AccessEffects of General Anesthesia Plus Multimodal Analgesia on Immediate Perioperative Outcomes of Hamstring Tendon Autograft ACL Reconstruction
Background: Anterior cruciate ligament reconstruction with hamstring tendon autograft (H-ACLR) is a standard ambulatory procedure with the potential for considerable postoperative pain. We hypothesized that general anesthesia combined with a multimodal analgesia regimen would reduce postoperative opioid use associated with H-ACLR.Methods: This study was a single-center, surgeon-stratified, double-blinded, placebo-controlled, randomized clinical trial. The primary end point was the total postoperative opioid use during the immediate postoperative period, and secondary outcomes included postoperative knee pain, adverse events, and ambulatory discharge efficiency.Results: One hundred and twelve subjects, 18 to 52 years of age, were randomized to placebo (57 subjects) or combination multimodal analgesia (MA) (55 subjects). The MA group required fewer opioids postoperatively (mean ± standard deviation, 9.81 ± 7.58 versus 13.88 ± 8.49 morphine milligram equivalents; p = 0.010; effect size = −0.51). Similarly, the MA group required fewer opioids within the first 24 hours postoperatively (mean ± standard deviation, 16.56 ± 10.77 versus 22.13 ± 10.66 morphine milligram equivalents; p = 0.008; effect size = −0.52). The subjects in the MA group reported lower posteromedial knee pain (median [interquartile range, IQR]: 3.0 [0.0 to 5.0] versus 4.0 [2.0 to 5.0]; p = 0.027) at 1 hour postoperatively. Nausea medication was required for 10.5% of the subjects receiving the placebo versus 14.5% of the subjects receiving MA (p = 0.577). Pruritis was reported for 17.5% of subjects receiving the placebo versus 14.5% receiving MA (p = 0.798). The median time to discharge was 177 minutes (IQR, 150.5 to 201.0 minutes) for subjects receiving placebo versus 188 minutes (IQR, 160.0 to 222.0 minutes) for those receiving MA (p = 0.271).Conclusions: A combination of general anesthesia and local, regional, oral, and intravenous multimodal analgesia appears to reduce postoperative opioid requirements after H-ACLR compared with placebo. Adding preoperative patient education and focusing on donor-site analgesia may maximize perioperative outcomes.Level of Evidence: TherapeuticLevel I. See Instructions for Authors for a complete description of levels of evidence.
- 17 May 2022
- Published by Springer Nature
- p. 69-86
Anterior Cruciate Ligament Injury and Reconstruction
- Open Access
- 3 December 2019
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 34 (08) , 828-833
Intraoperative Conversion to Five-Strand Hamstring Autograft Configuration Significantly Increases Anterior Cruciate Ligament Graft Diameter Independent of Patient Characteristics
Intraoperative conversion of a four-strand hamstring autograft to a five-strand configuration during an anterior cruciate ligament (ACL) reconstruction has been reported. However, the expected change in graft size and the dependence on patient characteristics are currently not well described. The purpose of this study was to determine the effective change in hamstring graft diameter and reliance on patient characteristics when intraoperatively converting a four-strand hamstring autograft into a five-strand configuration during an ACL reconstruction. A prospective, paired cohort study design was used to measure individual hamstring autograft diameter intraoperatively using traditional four-strand configuration followed by a five-strand configuration. All hamstring tendons included were long enough to consider a five-strand configuration. Five-strand hamstring autograft increased graft diameter in all patients. Hamstring tendon graft diameter increased by an average of 0.99 mm (95% confidence interval [CI]: 0.84–1.11) in the five-strand configuration compared with the traditional four-strand configuration (mean: 7.8 mm). There was no significant difference in the average increase in graft diameter between males (1.04 mm) and females (0.92 mm) (p = 0.323). Eighty-three percent (95% CI: 57.8–95.6) of average graft diameters ≤ 8 mm in the four-strand configuration achieved an average graft diameter of >8 mm in the five-strand configuration, and 70% (95% CI: 35.4– 91.9) of four-strand configuration average diameters < 8 mm achieved an average graft diameter > 8.0 mm in the five-strand configuration. Five-strand hamstring autograft reliably increased intraoperative hamstring tendon autograft diameter, with an average of 1 mm, compared with traditional four-strand configuration. This increase in diameter is independent of sex and remained significant when controlling for age, laterality, body mass index, and semitendinosus length.
- 3 December 2019
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 34 (08) , 828-833
Open AccessIntraoperative Conversion to Five-Strand Hamstring Autograft Configuration Significantly Increases Anterior Cruciate Ligament Graft Diameter Independent of Patient Characteristics
Intraoperative conversion of a four-strand hamstring autograft to a five-strand configuration during an anterior cruciate ligament (ACL) reconstruction has been reported. However, the expected change in graft size and the dependence on patient characteristics are currently not well described. The purpose of this study was to determine the effective change in hamstring graft diameter and reliance on patient characteristics when intraoperatively converting a four-strand hamstring autograft into a five-strand configuration during an ACL reconstruction. A prospective, paired cohort study design was used to measure individual hamstring autograft diameter intraoperatively using traditional four-strand configuration followed by a five-strand configuration. All hamstring tendons included were long enough to consider a five-strand configuration. Five-strand hamstring autograft increased graft diameter in all patients. Hamstring tendon graft diameter increased by an average of 0.99 mm (95% confidence interval [CI]: 0.84–1.11) in the five-strand configuration compared with the traditional four-strand configuration (mean: 7.8 mm). There was no significant difference in the average increase in graft diameter between males (1.04 mm) and females (0.92 mm) (p = 0.323). Eighty-three percent (95% CI: 57.8–95.6) of average graft diameters ≤ 8 mm in the four-strand configuration achieved an average graft diameter of >8 mm in the five-strand configuration, and 70% (95% CI: 35.4– 91.9) of four-strand configuration average diameters < 8 mm achieved an average graft diameter > 8.0 mm in the five-strand configuration. Five-strand hamstring autograft reliably increased intraoperative hamstring tendon autograft diameter, with an average of 1 mm, compared with traditional four-strand configuration. This increase in diameter is independent of sex and remained significant when controlling for age, laterality, body mass index, and semitendinosus length.
- Open Access
- 1 January 2015
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 2 (1) , 1-9
Intratendinous injections of platelet‐rich plasma: feasibility and effect on tendon morphology and mechanics
Background: Intratendinous injections may have important effects on the properties of collagen microarchitecture, morphology, and subsequent mechanical properties of the injected tendon. The purpose of this study was to examine the effects of intratendinous PRP injections; the injectant retention within tendons, the distribution of intratendinous injectant, and whether intratendinous injection or needle fenestration alters tendon morphology or mechanics.Methods: Design: Controlled Laboratory Study.Interventions: In the first part of the study, 18 lamb extensor tendons were selected to receive methylene blue‐containing PRP injection (PRP/MB), methylene blue only injection (MB), or needle fenestration. The volume of retained injectant was measured and injectant distribution and tendon morphology were examined microscopically. In the second portion of the study, 18 porcine flexor tendons were divided into control, needle fenestration, or saline injection groups. Young’s Modulus was then determined for each tendon under 0‐4% strain.Main outcome measures: 1) Injectant volume retained; 2) Injectant distribution; 3) Post‐injection/fenestration alterations in morphology, biomechanics.Results: Intratendinous injectant is retained within the tendon. The difference between PRP and PRP/MB groups was not significant (p = 0.78). Intratendinous spread of the injectant solution within the tendon occurs primarily in the proximodistal direction, with very little cross‐sectional penetration. Intratendinous injections resulted in microscopic morphology disruption (e.g., separation and disorganization of both the collagen bundles and cellular distribution).There were significant differences in Young’s Modulus between control (Ectrl = 2415.48) and injected tendons (Einj = 1753.45) at 4% strain (p = 0.01). There were no differences in Young’s Modulus between fenestrated and control tendons.Conclusions: Intratendinous PRP injections are retained within the tendon, and primarily distributes longitudinally with minimal cross‐sectional spread. Intratendinous injections may alter tendon morphology and mechanics.
- 1 January 2015
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 2 (1) , 1-9
Open AccessIntratendinous injections of platelet‐rich plasma: feasibility and effect on tendon morphology and mechanics
Background: Intratendinous injections may have important effects on the properties of collagen microarchitecture, morphology, and subsequent mechanical properties of the injected tendon. The purpose of this study was to examine the effects of intratendinous PRP injections; the injectant retention within tendons, the distribution of intratendinous injectant, and whether intratendinous injection or needle fenestration alters tendon morphology or mechanics.Methods: Design: Controlled Laboratory Study.Interventions: In the first part of the study, 18 lamb extensor tendons were selected to receive methylene blue‐containing PRP injection (PRP/MB), methylene blue only injection (MB), or needle fenestration. The volume of retained injectant was measured and injectant distribution and tendon morphology were examined microscopically. In the second portion of the study, 18 porcine flexor tendons were divided into control, needle fenestration, or saline injection groups. Young’s Modulus was then determined for each tendon under 0‐4% strain.Main outcome measures: 1) Injectant volume retained; 2) Injectant distribution; 3) Post‐injection/fenestration alterations in morphology, biomechanics.Results: Intratendinous injectant is retained within the tendon. The difference between PRP and PRP/MB groups was not significant (p = 0.78). Intratendinous spread of the injectant solution within the tendon occurs primarily in the proximodistal direction, with very little cross‐sectional penetration. Intratendinous injections resulted in microscopic morphology disruption (e.g., separation and disorganization of both the collagen bundles and cellular distribution).There were significant differences in Young’s Modulus between control (Ectrl = 2415.48) and injected tendons (Einj = 1753.45) at 4% strain (p = 0.01). There were no differences in Young’s Modulus between fenestrated and control tendons.Conclusions: Intratendinous PRP injections are retained within the tendon, and primarily distributes longitudinally with minimal cross‐sectional spread. Intratendinous injections may alter tendon morphology and mechanics.
- 1 December 2014
- Published by Elsevier in Journal of Biomechanics
- Vol. 47 (16) , 3813-3819
Influence of tendon tears on ultrasound echo intensity in response to loading
- 1 December 2014
- Published by Elsevier in Journal of Biomechanics
- Vol. 47 (16) , 3813-3819
Influence of tendon tears on ultrasound echo intensity in response to loading
- Open Access
- 18 April 2014
- Published by Taylor & Francis in Connective Tissue Research
- Vol. 55 (3) , 177-186
Interleukin-1 receptor antagonist modulates inflammation and scarring after ligament injury
Ligaments have limited regenerative potential and as a consequence, repair is protracted and results in a mechanically inferior tissue more scar-like than native ligament. We previously reported that a single injection of interleukin-1 receptor antagonist (IL-1Ra) delivered at the time of injury, decreased the number of M2 macrophage-associated inflammatory cytokines. Based on these results, we hypothesized that IL-1Ra administered after injury and closer to peak inflammation (as would occur clinically), would more effectively decrease inflammation and thereby improve healing. Since IL-1Ra has a short half-life, we also investigated the effect of multiple injections. The objective of this study was to elucidate healing of a medial collateral ligament (MCL) with either a single IL-1Ra injection delivered one day after injury or with multiple injections of IL-1Ra on days 1, 2, 3, and 4. One day after MCL injury, rats received either single or multiple injections of IL-1Ra or PBS. Tissue was then collected at days 5 and 11. Both single and multiple IL-1Ra injections reduced inflammatory cytokines, but did not change mechanical behavior. A single injection of IL-1Ra also reduced the number of myofibroblasts and increased type I procollagen. Multiple IL-1Ra doses provided no additive response and, in fact, reduced the M2 macrophages. Based on these results, a single dose of IL-1Ra was better at reducing the MCL-derived inflammatory cytokines compared to multiple injections. The changes in type I procollagen and myofibroblasts further suggest a single injection of IL-1Ra enhanced repair of the ligament but not sufficiently to improve functional behavior.
- 18 April 2014
- Published by Taylor & Francis in Connective Tissue Research
- Vol. 55 (3) , 177-186
Open AccessInterleukin-1 receptor antagonist modulates inflammation and scarring after ligament injury
Ligaments have limited regenerative potential and as a consequence, repair is protracted and results in a mechanically inferior tissue more scar-like than native ligament. We previously reported that a single injection of interleukin-1 receptor antagonist (IL-1Ra) delivered at the time of injury, decreased the number of M2 macrophage-associated inflammatory cytokines. Based on these results, we hypothesized that IL-1Ra administered after injury and closer to peak inflammation (as would occur clinically), would more effectively decrease inflammation and thereby improve healing. Since IL-1Ra has a short half-life, we also investigated the effect of multiple injections. The objective of this study was to elucidate healing of a medial collateral ligament (MCL) with either a single IL-1Ra injection delivered one day after injury or with multiple injections of IL-1Ra on days 1, 2, 3, and 4. One day after MCL injury, rats received either single or multiple injections of IL-1Ra or PBS. Tissue was then collected at days 5 and 11. Both single and multiple IL-1Ra injections reduced inflammatory cytokines, but did not change mechanical behavior. A single injection of IL-1Ra also reduced the number of myofibroblasts and increased type I procollagen. Multiple IL-1Ra doses provided no additive response and, in fact, reduced the M2 macrophages. Based on these results, a single dose of IL-1Ra was better at reducing the MCL-derived inflammatory cytokines compared to multiple injections. The changes in type I procollagen and myofibroblasts further suggest a single injection of IL-1Ra enhanced repair of the ligament but not sufficiently to improve functional behavior.
- 10 April 2014
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 136 (5) , 051004-0510046
The Influence of Partial and Full Thickness Tears on Infraspinatus Tendon Strain Patterns
Tears on the bursal and articular sides of the rotator cuff tendons are known to behave differently and strain is thought to play a role in this difference. This study investigates the effect of tear location on the changes in three strain measurements (grip-to-grip, insertion, and mid-substance tissue) in a sheep infraspinatus tendon model during axial loading. We introduced a 14 mm wide defect near the insertion from either the articular or bursal side of the tendon to three depths (3 mm, 7 mm & full) progressively. For each condition, tendons were sinusoidally stretched (4% at 0.5 Hz) while insertion and mid-substance strains were tracked with surface markers. For a fixed load, grip-to-grip strain increased significantly compared to intact for both cuts. Insertion strain increased significantly for the bursal-side defect immediately but not for the articular-side until the 66% cut. Mid-substance tissue strain showed no significant change for partial thickness articular-side defects and a significant decrease for bursal-side defects after the 66% cut. All full thickness cuts exhibited negligible mid-substance tissue strain change. Our results suggest that the tendon strain patterns are more sensitive to defects on the bursal side, and that partial thickness tears tend to induce localized strain concentrations in regions adjacent to the damaged tissue.
- 10 April 2014
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 136 (5) , 051004-0510046
The Influence of Partial and Full Thickness Tears on Infraspinatus Tendon Strain Patterns
Tears on the bursal and articular sides of the rotator cuff tendons are known to behave differently and strain is thought to play a role in this difference. This study investigates the effect of tear location on the changes in three strain measurements (grip-to-grip, insertion, and mid-substance tissue) in a sheep infraspinatus tendon model during axial loading. We introduced a 14 mm wide defect near the insertion from either the articular or bursal side of the tendon to three depths (3 mm, 7 mm & full) progressively. For each condition, tendons were sinusoidally stretched (4% at 0.5 Hz) while insertion and mid-substance strains were tracked with surface markers. For a fixed load, grip-to-grip strain increased significantly compared to intact for both cuts. Insertion strain increased significantly for the bursal-side defect immediately but not for the articular-side until the 66% cut. Mid-substance tissue strain showed no significant change for partial thickness articular-side defects and a significant decrease for bursal-side defects after the 66% cut. All full thickness cuts exhibited negligible mid-substance tissue strain change. Our results suggest that the tendon strain patterns are more sensitive to defects on the bursal side, and that partial thickness tears tend to induce localized strain concentrations in regions adjacent to the damaged tissue.
- 1 January 2012
- Published by Elsevier
- p. 428-434
Complications of Anterior Cruciate Ligament Reconstruction
- 1 January 2012
- Published by Elsevier
- p. 428-434
Complications of Anterior Cruciate Ligament Reconstruction
- 1 January 2010
- Published by Elsevier
- p. 651-656
Osteoarthritis of the Knee