Priyadharshini Ramu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Priyadharshini Ramu has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Sivasankar Gangatharan
Department of Electrical and Electronics Engineering, Thiagarajar College of Engineering, Madurai 625015, India
2 shared publications - Lucian Mihet-Popa
Faculty of Engineering, stfold University College, Halden, Norway
1 shared publication - Sankar Rangasamy
Department of Electrical and Electronics Engineering, Chennai Institute of Technology, Chennai, India
1 shared publication
Latest Publications
- Open Access
- 9 August 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (16) , 12209
Categorization of Loads in Educational Institutions to Effectively Manage Peak Demand and Minimize Energy Cost Using an Intelligent Load Management Technique
The inclusion of photovoltaics (PV) in electric power supply systems continues to be a significant factor in global interest. However, solar power exhibits intermittent uncertainty and is further unpredictable. Accurate solar generation prediction and efficient utilization are mandatory for power distribution management and demand-side management. Peak demand management and reducing energy costs can be effectively tackled through the implementation of a reliable solar power forecasting system and its efficient utilization. In this regard, the proposed work is related to efficiently managing solar PV power and optimizing power distribution using an enhanced reinforced binary particle swarm optimization (RBPSO) technique. This DSM (demand-side management) strategy involves utilizing a forecast of solar PV generation for the upcoming day and adjusting the consumption schedule of the load to decrease the highest energy demand. The proposed approach improves user comfort by adjusting the non-interruptible and flexible institutional load through clipping and shifting techniques. To evaluate the effectiveness of this approach, its performance is assessed by analyzing the peak demand range and PAR (peak-to-average ratio). It is then compared to the conventional genetic algorithm to determine its effectiveness. Simulation results obtained using MATLAB show that the PAR peak demand before DSM was found to be 1.8602 kW and 378.06 kW, and after DSM, it was reduced to 0.7211 kW and 266.54 kW. This indicates a 29% reduction in Peak demand and performance compared to the conventional genetic algorithm (GA).
- 9 August 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (16) , 12209
Open AccessCategorization of Loads in Educational Institutions to Effectively Manage Peak Demand and Minimize Energy Cost Using an Intelligent Load Management Technique
The inclusion of photovoltaics (PV) in electric power supply systems continues to be a significant factor in global interest. However, solar power exhibits intermittent uncertainty and is further unpredictable. Accurate solar generation prediction and efficient utilization are mandatory for power distribution management and demand-side management. Peak demand management and reducing energy costs can be effectively tackled through the implementation of a reliable solar power forecasting system and its efficient utilization. In this regard, the proposed work is related to efficiently managing solar PV power and optimizing power distribution using an enhanced reinforced binary particle swarm optimization (RBPSO) technique. This DSM (demand-side management) strategy involves utilizing a forecast of solar PV generation for the upcoming day and adjusting the consumption schedule of the load to decrease the highest energy demand. The proposed approach improves user comfort by adjusting the non-interruptible and flexible institutional load through clipping and shifting techniques. To evaluate the effectiveness of this approach, its performance is assessed by analyzing the peak demand range and PAR (peak-to-average ratio). It is then compared to the conventional genetic algorithm to determine its effectiveness. Simulation results obtained using MATLAB show that the PAR peak demand before DSM was found to be 1.8602 kW and 378.06 kW, and after DSM, it was reduced to 0.7211 kW and 266.54 kW. This indicates a 29% reduction in Peak demand and performance compared to the conventional genetic algorithm (GA).
- 1 August 2023
- Published by Taylor & Francis in Journal of the Chinese Institute of Engineers
- Vol. 46 (7) , 737-753
An ensemble machine learning-based solar power prediction of meteorological variability conditions to improve accuracy in forecasting
- 1 August 2023
- Published by Taylor & Francis in Journal of the Chinese Institute of Engineers
- Vol. 46 (7) , 737-753
An ensemble machine learning-based solar power prediction of meteorological variability conditions to improve accuracy in forecasting