Ubaldo Ramon Julvez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ubaldo Ramon Julvez has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Monica Hernandez
University of Zaragoza
2 shared publications - Beatriz Cordón
Department of Ophthalmology, Miguel Servet University Hospital, 50009 Zaragoza, Spain
1 shared publication Elena Garcia-Martin
Affiliation Ophtalmology Department, Miguel Servet Hospital, Zaragoza, Spain
1 shared publicationElisa Vilades
Affiliation Ophtalmology Department, Miguel Servet Hospital, Zaragoza, Spain
1 shared publicationElvira Mayordomo
Affiliations Computer Science Department, University of Zaragoza, Zaragoza, Spain, Aragon Institute on Engineering Research, Zaragoza, Spain
1 shared publication
Latest Publications
- Open Access
- 21 June 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 178, 108761
Insights into traditional Large Deformation Diffeomorphic Metric Mapping and unsupervised deep-learning for diffeomorphic registration and their evaluation
- 21 June 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 178, 108761
Open AccessInsights into traditional Large Deformation Diffeomorphic Metric Mapping and unsupervised deep-learning for diffeomorphic registration and their evaluation
- Open Access
- 7 August 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (8) , e0289495
Explainable artificial intelligence toward usable and trustworthy computer-aided diagnosis of multiple sclerosis from Optical Coherence Tomography
Background: Several studies indicate that the anterior visual pathway provides information about the dynamics of axonal degeneration in Multiple Sclerosis (MS). Current research in the field is focused on the quest for the most discriminative features among patients and controls and the development of machine learning models that yield computer-aided solutions widely usable in clinical practice. However, most studies are conducted with small samples and the models are used as black boxes. Clinicians should not trust machine learning decisions unless they come with comprehensive and easily understandable explanations. Materials and methods: A total of 216 eyes from 111 healthy controls and 100 eyes from 59 patients with relapsing-remitting MS were enrolled. The feature set was obtained from the thickness of the ganglion cell layer (GCL) and the retinal nerve fiber layer (RNFL). Measurements were acquired by the novel Posterior Pole protocol from Spectralis Optical Coherence Tomography (OCT) device. We compared two black-box methods (gradient boosting and random forests) with a glass-box method (explainable boosting machine). Explainability was studied using SHAP for the black-box methods and the scores of the glass-box method. Results: The best-performing models were obtained for the GCL layer. Explainability pointed out to the temporal location of the GCL layer that is usually broken or thinning in MS and the relationship between low thickness values and high probability of MS, which is coherent with clinical knowledge. Conclusions: The insights on how to use explainability shown in this work represent a first important step toward a trustworthy computer-aided solution for the diagnosis of MS with OCT.
- 7 August 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (8) , e0289495
Open AccessExplainable artificial intelligence toward usable and trustworthy computer-aided diagnosis of multiple sclerosis from Optical Coherence Tomography
Background: Several studies indicate that the anterior visual pathway provides information about the dynamics of axonal degeneration in Multiple Sclerosis (MS). Current research in the field is focused on the quest for the most discriminative features among patients and controls and the development of machine learning models that yield computer-aided solutions widely usable in clinical practice. However, most studies are conducted with small samples and the models are used as black boxes. Clinicians should not trust machine learning decisions unless they come with comprehensive and easily understandable explanations. Materials and methods: A total of 216 eyes from 111 healthy controls and 100 eyes from 59 patients with relapsing-remitting MS were enrolled. The feature set was obtained from the thickness of the ganglion cell layer (GCL) and the retinal nerve fiber layer (RNFL). Measurements were acquired by the novel Posterior Pole protocol from Spectralis Optical Coherence Tomography (OCT) device. We compared two black-box methods (gradient boosting and random forests) with a glass-box method (explainable boosting machine). Explainability was studied using SHAP for the black-box methods and the scores of the glass-box method. Results: The best-performing models were obtained for the GCL layer. Explainability pointed out to the temporal location of the GCL layer that is usually broken or thinning in MS and the relationship between low thickness values and high probability of MS, which is coherent with clinical knowledge. Conclusions: The insights on how to use explainability shown in this work represent a first important step toward a trustworthy computer-aided solution for the diagnosis of MS with OCT.