Juliana Gretz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Juliana Gretz has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Sebastian Kruss
Ruhr-University Bochum
8 shared publications Jennifer M. Mohr
Ruhr-University Bochum
3 shared publications- Bjoern F. Hill
Ruhr University Bochum
2 shared publications - C. Alexander Schrage
Department of Chemistry and Biochemistry, Ruhr-University Bochum, Universitätsstraße 150, 44801 Bochum, Germany
2 shared publications Chen Ma
Ruhr-University Bochum
2 shared publications- Chen Ma
Department of Chemistry, Ruhr University Bochum, 44801 Bochum, Germany
2 shared publications
Latest Publications
- 2 October 2026
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 130 (41) , 14241-14247
Quantum Defect Density Controls Carbon Nanotube Sensor Sensitivity via Photophysical Cooperativity
Single-walled carbon nanotubes (SWCNTs) fluoresce in the near-infrared (NIR), overlapping with the biological transparency window. Therefore, SWCNTs are used as versatile materials for (bio)photonics. Controlled covalent functionalization of SWCNTs with quantum defects (QDs) creates color-center carbon nanotubes (CCNTs) with red-shifted additional emission features and increased overall emission. QDs represent a new chemical dimension for sensing. However, it is unclear how the number of QDs affects sensor properties such as sensitivity or dynamic range. Here, we develop an NIR fluorescent ratiometric pH sensor based on benzoic acid QDs. We vary the amount of QDs in (6,5)-chirality-enriched CCNTs and demonstrate that the amount of pH-sensitive QDs does not affect the dynamic range of the nanosensor (pH approximately 6.8–7.9), but influences the sensitivity (ratiometric response E11*/E11) by more than 100%. We attribute this impact of defect density on sensing to positive photophysical cooperativity between QDs, while the dissociation constant of the (pKa) of the quantum defect determines the dynamic range of the sensor. These pH-sensitive CCNTs can be incorporated into agar hydrogels for ratiometric (1130 nm/990 nm) pH imaging. Overall, we show that the number of QDs is an efficient tool to tune the sensitivity of fluorescent sensors.
- 2 October 2026
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 130 (41) , 14241-14247
Quantum Defect Density Controls Carbon Nanotube Sensor Sensitivity via Photophysical Cooperativity
Single-walled carbon nanotubes (SWCNTs) fluoresce in the near-infrared (NIR), overlapping with the biological transparency window. Therefore, SWCNTs are used as versatile materials for (bio)photonics. Controlled covalent functionalization of SWCNTs with quantum defects (QDs) creates color-center carbon nanotubes (CCNTs) with red-shifted additional emission features and increased overall emission. QDs represent a new chemical dimension for sensing. However, it is unclear how the number of QDs affects sensor properties such as sensitivity or dynamic range. Here, we develop an NIR fluorescent ratiometric pH sensor based on benzoic acid QDs. We vary the amount of QDs in (6,5)-chirality-enriched CCNTs and demonstrate that the amount of pH-sensitive QDs does not affect the dynamic range of the nanosensor (pH approximately 6.8–7.9), but influences the sensitivity (ratiometric response E11*/E11) by more than 100%. We attribute this impact of defect density on sensing to positive photophysical cooperativity between QDs, while the dissociation constant of the (pKa) of the quantum defect determines the dynamic range of the sensor. These pH-sensitive CCNTs can be incorporated into agar hydrogels for ratiometric (1130 nm/990 nm) pH imaging. Overall, we show that the number of QDs is an efficient tool to tune the sensitivity of fluorescent sensors.
- Open Access
- 16 July 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Quantum defect density controls carbon nanotube sensor sensitivity via photophysical cooperativity
Single-walled carbon nanotubes (SWCNTs) fluoresce in the near-infrared (NIR), which overlaps with the biological transparency window. Therefore, SWCNTs are used as versatile materials for (bio)photonics. Controlled covalent functionalization of SWCNTs with quantum defects (QDs) creates color center carbon nanotubes (CCNTs) with red-shifted additional emission features and increased overall emission. QDs are a new chemical dimension for sensing but is unclear how the number of QDs affect sensor properties such as sensitivity or dynamic range. Here, we develop a NIR fluorescent ratiometric pH sensor based on benzoic acid QDs. We vary the amount of QDs in (6,5)-chirality enriched CCNTs and demonstrate that the amount of pH-sensitive QDs does not affect the dynamic range of the nanosensor (pH = 6.0-8.5), but influences the sensitivity (ratiometric response E 11 */E 11 ) by more than 100 %. We attribute this impact of defect density on sensing to photophysical positive cooperativity between QDs, while the dissociation constant of the (pKa-value) of the quantum defect determines the dynamic range of the sensor. These pH sensitive CCNTs can be incorporated into agarhydrogels for ratiometric (1130 nm / 990 nm) pH imaging. Overall, we show that the number of QDs is an efficient tool to tune properties of fluorescent sensors.
- 16 July 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessQuantum defect density controls carbon nanotube sensor sensitivity via photophysical cooperativity
Single-walled carbon nanotubes (SWCNTs) fluoresce in the near-infrared (NIR), which overlaps with the biological transparency window. Therefore, SWCNTs are used as versatile materials for (bio)photonics. Controlled covalent functionalization of SWCNTs with quantum defects (QDs) creates color center carbon nanotubes (CCNTs) with red-shifted additional emission features and increased overall emission. QDs are a new chemical dimension for sensing but is unclear how the number of QDs affect sensor properties such as sensitivity or dynamic range. Here, we develop a NIR fluorescent ratiometric pH sensor based on benzoic acid QDs. We vary the amount of QDs in (6,5)-chirality enriched CCNTs and demonstrate that the amount of pH-sensitive QDs does not affect the dynamic range of the nanosensor (pH = 6.0-8.5), but influences the sensitivity (ratiometric response E 11 */E 11 ) by more than 100 %. We attribute this impact of defect density on sensing to photophysical positive cooperativity between QDs, while the dissociation constant of the (pKa-value) of the quantum defect determines the dynamic range of the sensor. These pH sensitive CCNTs can be incorporated into agarhydrogels for ratiometric (1130 nm / 990 nm) pH imaging. Overall, we show that the number of QDs is an efficient tool to tune properties of fluorescent sensors.
- 4 July 2026
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 26 (27) , 8842-8849
Nanoscale Organization of Membrane Tension during Neutrophil Extracellular Trap Formation Revealed by Fluorescence Lifetime Imaging
Cells generate and respond to mechanical forces across compartments, with the plasma membrane acting as a nanoscale interface for sensing and transmitting tension. How intracellular forces translate into membrane tension during dynamic processes such as neutrophil extracellular trap (NET) formation remains unclear. Here, we combine the mechanosensitive fluorescent probe Flipper-TR with fluorescence lifetime imaging microscopy (FLIM) to map spatiotemporal plasma membrane tension changes in living cells. After validation in HeLa and dHL-60 cells under osmotic perturbation, we apply this approach to primary human neutrophils undergoing NETosis. Membrane tension transiently increases during chromatin decondensation and nuclear swelling within 60 min, followed by a marked decrease after membrane rupture. Prior to rupture, tension is spatially heterogeneous, indicating localized nanoscale mechanical regulation. Cholesterol depletion abolishes the transient increase and reduces heterogeneity without affecting NETosis kinetics. These findings establish the plasma membrane as a dynamic nanoscale reporter of intracellular mechanical stress during NETosis.
- 4 July 2026
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 26 (27) , 8842-8849
Nanoscale Organization of Membrane Tension during Neutrophil Extracellular Trap Formation Revealed by Fluorescence Lifetime Imaging
Cells generate and respond to mechanical forces across compartments, with the plasma membrane acting as a nanoscale interface for sensing and transmitting tension. How intracellular forces translate into membrane tension during dynamic processes such as neutrophil extracellular trap (NET) formation remains unclear. Here, we combine the mechanosensitive fluorescent probe Flipper-TR with fluorescence lifetime imaging microscopy (FLIM) to map spatiotemporal plasma membrane tension changes in living cells. After validation in HeLa and dHL-60 cells under osmotic perturbation, we apply this approach to primary human neutrophils undergoing NETosis. Membrane tension transiently increases during chromatin decondensation and nuclear swelling within 60 min, followed by a marked decrease after membrane rupture. Prior to rupture, tension is spatially heterogeneous, indicating localized nanoscale mechanical regulation. Cholesterol depletion abolishes the transient increase and reduces heterogeneity without affecting NETosis kinetics. These findings establish the plasma membrane as a dynamic nanoscale reporter of intracellular mechanical stress during NETosis.
- 25 December 2025
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 20 (1) , 744-753
Kinetic Insights Into Carbon Nanotube-Based Neurotransmitter Sensors by Single Molecule Experiments
Single-walled carbon nanotubes (SWCNTs) are powerful building blocks for near-infrared (NIR) fluorescent biosensors. They can be chemically tailored to detect specific biomolecules. Their performance in (bio)imaging applications depends on how fast analytes bind orunbind and change their fluorescence, but measuring fast kinetics remains a challenge. Here, we demonstrate single-molecule detection by single SWCNT-based nanosensors and measure their rate constants. We use fluorescence microscopy (>900 nm) to image DNA functionalized (6,5)-SWCNTs, which detect the neurotransmitters dopamine and epinephrine as well as the interfering molecule ascorbic acid. By analyzing fluorescence traces of these sensors, we directly observe binding and unbinding events of individual analyte molecules. Hidden Markov modeling allows us to obtain dwell times and consequently rate constants (koff). Debinding is best described by two exponential first order kinetics with koff,fast = 0.40 to 0.71 s-1 and koff,slow = 0.01 to 0.10 s-1 depending on DNA sequence and analyte. Additionally, we find that sensitivity is correlated with sensor brightness and darker sensors have faster off-rates. We also show that differences in rate constants can be exploited for kinetically improved sensor selectivity (KISS) beyond the thermodynamic limit. Overall, we provide fundamental insights into the kinetics and mechanism of SWCNT-based sensors and propose a concept for kinetic selectivity.
- 25 December 2025
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 20 (1) , 744-753
Kinetic Insights Into Carbon Nanotube-Based Neurotransmitter Sensors by Single Molecule Experiments
Single-walled carbon nanotubes (SWCNTs) are powerful building blocks for near-infrared (NIR) fluorescent biosensors. They can be chemically tailored to detect specific biomolecules. Their performance in (bio)imaging applications depends on how fast analytes bind orunbind and change their fluorescence, but measuring fast kinetics remains a challenge. Here, we demonstrate single-molecule detection by single SWCNT-based nanosensors and measure their rate constants. We use fluorescence microscopy (>900 nm) to image DNA functionalized (6,5)-SWCNTs, which detect the neurotransmitters dopamine and epinephrine as well as the interfering molecule ascorbic acid. By analyzing fluorescence traces of these sensors, we directly observe binding and unbinding events of individual analyte molecules. Hidden Markov modeling allows us to obtain dwell times and consequently rate constants (koff). Debinding is best described by two exponential first order kinetics with koff,fast = 0.40 to 0.71 s-1 and koff,slow = 0.01 to 0.10 s-1 depending on DNA sequence and analyte. Additionally, we find that sensitivity is correlated with sensor brightness and darker sensors have faster off-rates. We also show that differences in rate constants can be exploited for kinetically improved sensor selectivity (KISS) beyond the thermodynamic limit. Overall, we provide fundamental insights into the kinetics and mechanism of SWCNT-based sensors and propose a concept for kinetic selectivity.
- Open Access
- 2 September 2025
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 27 (36) , 18855-18869
The euroSAMPL1 p K a blind prediction and reproducible research data management challenge
The euroSAMPL1 p K a prediction challenge combined performance measurements of computational methods with peer-evaluated adherence to research data management FAIR principles.
- 2 September 2025
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 27 (36) , 18855-18869
Open AccessThe euroSAMPL1 p K a blind prediction and reproducible research data management challenge
The euroSAMPL1 p K a prediction challenge combined performance measurements of computational methods with peer-evaluated adherence to research data management FAIR principles.
- Open Access
- 18 March 2025
- Published by Elsevier in Carbon Trends
- Vol. 19
3D printing of models of carbon nanotubes and related nanomaterials
- 18 March 2025
- Published by Elsevier in Carbon Trends
- Vol. 19
Open Access3D printing of models of carbon nanotubes and related nanomaterials
- Open Access
- 4 September 2024
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 16 (39) , 18534-18544
Ratiometric near infrared fluorescence imaging of dopamine with 1D and 2D nanomaterials
We combine Egyptian blue nanosheets and DNA-modified monochiral SWCNTs to create a ratiometric near infrared fluorescent sensor for the neurotransmitter dopamine. It enables robust imaging of dopamine-release from neurons.
- 4 September 2024
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 16 (39) , 18534-18544
Open AccessRatiometric near infrared fluorescence imaging of dopamine with 1D and 2D nanomaterials
We combine Egyptian blue nanosheets and DNA-modified monochiral SWCNTs to create a ratiometric near infrared fluorescent sensor for the neurotransmitter dopamine. It enables robust imaging of dopamine-release from neurons.
- Open Access
- 4 April 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Ratiometric Near Infrared Fluorescence Imaging of Dopamine with 1D and 2D nanomaterials
Neurotransmitters are released by neuronal cells to exchange information. Resolving their spatiotemporal patterns is crucial to understand chemical neurotransmission. Here, we present a ratiometric sensor for the neurotransmitter dopamine that combines Egyptian Blue (CaCuSi4O10) nanosheets (EB-NS) and single-walled carbon nanotubes (SWCNTs). They both fluoresce in near infrared (NIR), which is beneficial due to ultra-low background and phototoxicity. (GT)10-DNA functionalized monochiral (6,5)-SWCNTs increase their fluorescence (1000 nm) in response to dopamine, while EB-NS serves as stable reference (936 nm). A robust ratiometric imaging scheme is implemented by directing these signals on two different NIR sensitive cameras. Additionally, we demonstrate stability against mechanical perturbations and image dopamine release from differentiated dopaminergic Neuro 2a cells. Therefore, this technique enables robust ratiometric and non-invasive imaging of cellular responses.
- 4 April 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessRatiometric Near Infrared Fluorescence Imaging of Dopamine with 1D and 2D nanomaterials
Neurotransmitters are released by neuronal cells to exchange information. Resolving their spatiotemporal patterns is crucial to understand chemical neurotransmission. Here, we present a ratiometric sensor for the neurotransmitter dopamine that combines Egyptian Blue (CaCuSi4O10) nanosheets (EB-NS) and single-walled carbon nanotubes (SWCNTs). They both fluoresce in near infrared (NIR), which is beneficial due to ultra-low background and phototoxicity. (GT)10-DNA functionalized monochiral (6,5)-SWCNTs increase their fluorescence (1000 nm) in response to dopamine, while EB-NS serves as stable reference (936 nm). A robust ratiometric imaging scheme is implemented by directing these signals on two different NIR sensitive cameras. Additionally, we demonstrate stability against mechanical perturbations and image dopamine release from differentiated dopaminergic Neuro 2a cells. Therefore, this technique enables robust ratiometric and non-invasive imaging of cellular responses.
- 1 August 2023
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 17 (16) , 15989-15998
Stochastic Formation of Quantum Defects in Carbon Nanotubes
Small perturbations in the structure of materials significantly affect their properties. One example is single wall carbon nanotubes (SWCNTs), which exhibit chirality-dependent near-infrared (NIR) fluorescence. They can be modified with quantum defects through the reaction with diazonium salts, and the number or distribution of these defects determines their photophysics. However, the presence of multiple chiralities in typical SWCNT samples complicates the identification of defect-related emission features. Here, we show that quantum defects do not affect aqueous two-phase extraction (ATPE) of different SWCNT chiralities into different phases, which suggests low numbers of defects. For bulk samples, the bandgap emission (E11) of monochiral (6,5)-SWCNTs decreases, and the defect-related emission feature (E11*) increases with diazonium salt concentration and represents a proxy for the defect number. The high purity of monochiral samples from ATPE allows us to image NIR fluorescence contributions (E11 = 986 nm and E11* = 1140 nm) on the single SWCNT level. Interestingly, we observe a stochastic (Poisson) distribution of quantum defects. SWCNTs have most likely one to three defects (for low to high (bulk) quantum defect densities). Additionally, we verify this number by following single reaction events that appear as discrete steps in the temporal fluorescence traces. We thereby count single reactions via NIR imaging and demonstrate that stochasticity plays a crucial role in the optical properties of SWCNTs. These results show that there can be a large discrepancy between ensemble and single particle experiments/properties of nanomaterials.
- 1 August 2023
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 17 (16) , 15989-15998
Stochastic Formation of Quantum Defects in Carbon Nanotubes
Small perturbations in the structure of materials significantly affect their properties. One example is single wall carbon nanotubes (SWCNTs), which exhibit chirality-dependent near-infrared (NIR) fluorescence. They can be modified with quantum defects through the reaction with diazonium salts, and the number or distribution of these defects determines their photophysics. However, the presence of multiple chiralities in typical SWCNT samples complicates the identification of defect-related emission features. Here, we show that quantum defects do not affect aqueous two-phase extraction (ATPE) of different SWCNT chiralities into different phases, which suggests low numbers of defects. For bulk samples, the bandgap emission (E11) of monochiral (6,5)-SWCNTs decreases, and the defect-related emission feature (E11*) increases with diazonium salt concentration and represents a proxy for the defect number. The high purity of monochiral samples from ATPE allows us to image NIR fluorescence contributions (E11 = 986 nm and E11* = 1140 nm) on the single SWCNT level. Interestingly, we observe a stochastic (Poisson) distribution of quantum defects. SWCNTs have most likely one to three defects (for low to high (bulk) quantum defect densities). Additionally, we verify this number by following single reaction events that appear as discrete steps in the temporal fluorescence traces. We thereby count single reactions via NIR imaging and demonstrate that stochasticity plays a crucial role in the optical properties of SWCNTs. These results show that there can be a large discrepancy between ensemble and single particle experiments/properties of nanomaterials.