Fabrizio Lo Regio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fabrizio Lo Regio has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Leopoldo Angrisani
Department of Information Technology and Electrical Engineering (DIETI), University of Naples Federico II, Naples, Italy
10 shared publications - Egidio De Benedetto
Department of Information Technology and Electrical Engineering (DIETI), University of Naples Federico II, 80125 Naples, Italy
9 shared publications - Luigi Duraccio
Department of Information Technology and Electrical Engineering (DIETI), University of Naples Federico II, Naples, Italy
9 shared publications - Annarita Tedesco
Department of Public Health, University of Naples Federico II, Via Pansini, 80131 Naples, Italy
8 shared publications - Mauro D'Arco
Department of Information Technology and Electrical Engineering (DIETI), University of Naples Federico II, Naples, Italy
5 shared publications - Matteo D’IOrio
Department of Electrical Engineering and Information Technology (DIETI), University of Naples Federico II, Via Claudio n.21, 80125 Naples, Italy
2 shared publications
Latest Publications
- Open Access
- 5 May 2026
- Published by Elsevier in Measurement
- Vol. 278
Quantum-secured distributed measurement systems for critical infrastructures operations
- 5 May 2026
- Published by Elsevier in Measurement
- Vol. 278
Open AccessQuantum-secured distributed measurement systems for critical infrastructures operations
- Open Access
- 9 March 2026
- Published by Elsevier in Measurement
- Vol. 272
Extended reality head-mounted displays as measuring systems: Conceptualization and measurement uncertainty evaluation
- 9 March 2026
- Published by Elsevier in Measurement
- Vol. 272
Open AccessExtended reality head-mounted displays as measuring systems: Conceptualization and measurement uncertainty evaluation
- Open Access
Online Compensation of Systematic Effects in Stimuli Generation for XR-Based SSVEP BCIs
Background: Brain–Computer Interfaces (BCIs) based on Steady-State Visually Evoked Potentials (SSVEPs) and Extended Reality (XR) offer promising solutions for highly wearable applications, but their classification performance can be affected by systematic effects in stimulus presentation. Novelty: This study introduces a novel online compensation method to compensate for systematic effects in the Refresh Rate (RR) of XR displays, enhancing SSVEP classification without requiring additional training or invasive measurements. Methods: A non-invasive monitoring module was incorporated into the developed BCI pipeline to measure frame rate variations in the XR display, allowing deviations between nominal RR and measured values to be automatically detected and compensated for. Classification performance was evaluated using Filter Bank Canonical Correlation Analysis (FBCCA). Statistical significance was assessed using Student’s t-test. Materials: Two datasets were used: a dataset based on Moverio BT-350, including 9 subjects, and a dataset based on HoloLens 2, including 30 subjects, all collected by the authors. Results: The proposed compensation method led to significant improvements in SSVEP classification accuracy, proportional to the magnitude of fps deviations. In some cases, classification accuracy increased by up to 300% relative to its original value. Statistical analyses confirmed the reliability of the results across subjects and datasets. Conclusions: These findings show that the proposed method effectively enhances SSVEP-based BCIs in XR environments and provides a robust foundation for practical applications requiring high reliability.
Open AccessOnline Compensation of Systematic Effects in Stimuli Generation for XR-Based SSVEP BCIs
Background: Brain–Computer Interfaces (BCIs) based on Steady-State Visually Evoked Potentials (SSVEPs) and Extended Reality (XR) offer promising solutions for highly wearable applications, but their classification performance can be affected by systematic effects in stimulus presentation. Novelty: This study introduces a novel online compensation method to compensate for systematic effects in the Refresh Rate (RR) of XR displays, enhancing SSVEP classification without requiring additional training or invasive measurements. Methods: A non-invasive monitoring module was incorporated into the developed BCI pipeline to measure frame rate variations in the XR display, allowing deviations between nominal RR and measured values to be automatically detected and compensated for. Classification performance was evaluated using Filter Bank Canonical Correlation Analysis (FBCCA). Statistical significance was assessed using Student’s t-test. Materials: Two datasets were used: a dataset based on Moverio BT-350, including 9 subjects, and a dataset based on HoloLens 2, including 30 subjects, all collected by the authors. Results: The proposed compensation method led to significant improvements in SSVEP classification accuracy, proportional to the magnitude of fps deviations. In some cases, classification accuracy increased by up to 300% relative to its original value. Statistical analyses confirmed the reliability of the results across subjects and datasets. Conclusions: These findings show that the proposed method effectively enhances SSVEP-based BCIs in XR environments and provides a robust foundation for practical applications requiring high reliability.
- 9 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
An open Steady-State Visually Evoked Potentials Dataset for Augmented Reality-based Brain-Computer Interfaces
This paper presents an open benchmark dataset related to Steady-State Visually Evoked Potential (SSVEP) signals elicited by means of an augmented reality (AR) device. In addition to being the first open dataset that combines SSVEP elicited through AR, another important novelty is the fact this dataset was designed with a metrology-driven approach, monitoring and/or controlling influence factors that can impair target recognition. The dataset consists of 8-channel electroencephalogram (EEG) data acquired from 30 healthy subjects (15 experienced) while they performed a cue-guided target selection task. The flickering frequencies ranged from 8 Hz to 15 Hz with an interval of 1 Hz, while the phase difference between two adjacent flickers was set to π/2. The dataset comprises five acquisition cycles for each subject, with each cycle corresponding to signals recorded from all eight flickers, presented by the visual cues in a randomized order. The stimulation duration in each selection task was five seconds. To ensure the dataset’s trust-worthiness, two crucial parameters for effective stimulus recognition were monitored and/or controlled, namely the illuminance of the environment and the frames per second variation of the AR device, which are primary factors influencing the performance of AR-based SSVEP Brain-Computer Interfaces (BCIs). Additionally, acceleration and angular velocity data related to the subjects’ head movements were acquired. In this way, the proposed dataset addresses the gap in the availability of public datasets for AR-based SSVEP BCIs, serving as a benchmark for comparing different algorithms in i) target identification and ii) motion artifact detection. This contribution is crucial for advancing the development of portable BCI systems aligned with the human-centric principles of the Industry 5.0 paradigm.
- 9 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
An open Steady-State Visually Evoked Potentials Dataset for Augmented Reality-based Brain-Computer Interfaces
This paper presents an open benchmark dataset related to Steady-State Visually Evoked Potential (SSVEP) signals elicited by means of an augmented reality (AR) device. In addition to being the first open dataset that combines SSVEP elicited through AR, another important novelty is the fact this dataset was designed with a metrology-driven approach, monitoring and/or controlling influence factors that can impair target recognition. The dataset consists of 8-channel electroencephalogram (EEG) data acquired from 30 healthy subjects (15 experienced) while they performed a cue-guided target selection task. The flickering frequencies ranged from 8 Hz to 15 Hz with an interval of 1 Hz, while the phase difference between two adjacent flickers was set to π/2. The dataset comprises five acquisition cycles for each subject, with each cycle corresponding to signals recorded from all eight flickers, presented by the visual cues in a randomized order. The stimulation duration in each selection task was five seconds. To ensure the dataset’s trust-worthiness, two crucial parameters for effective stimulus recognition were monitored and/or controlled, namely the illuminance of the environment and the frames per second variation of the AR device, which are primary factors influencing the performance of AR-based SSVEP Brain-Computer Interfaces (BCIs). Additionally, acceleration and angular velocity data related to the subjects’ head movements were acquired. In this way, the proposed dataset addresses the gap in the availability of public datasets for AR-based SSVEP BCIs, serving as a benchmark for comparing different algorithms in i) target identification and ii) motion artifact detection. This contribution is crucial for advancing the development of portable BCI systems aligned with the human-centric principles of the Industry 5.0 paradigm.
- Open Access
Performance Measurement of Gesture-Based Human–Machine Interfaces Within eXtended Reality Head-Mounted Displays
This paper proposes a method for measuring the performance of Human–Machine Interfaces based on hand-gesture recognition, implemented within eXtended Reality Head-Mounted Displays. The proposed method leverages a systematic approach, enabling performance measurement in compliance with the Guide to the Expression of Uncertainty in Measurement. As an initial step, a testbed is developed, comprising a series of icons accommodated within the field of view of the eXtended Reality Head-Mounted Display considered. Each icon must be selected through a cue-guided task using the hand gestures under evaluation. Multiple selection cycles involving different individuals are conducted to derive suitable performance metrics. These metrics are derived considering the specific parameters characterizing the hand gestures, as well as the uncertainty contributions arising from intra- and inter-individual variability in the measured quantity values. As a case study, the eXtended Reality Head-Mounted Display Microsoft HoloLens 2 and the finger-tapping gesture were investigated. Without compromising generality, the obtained results show that the proposed method can provide valuable insights into performance trends across individuals and gesture parameters. Moreover, the statistical analyses employed can determine whether increased individual familiarity with the Human–Machine Interface results in faster task completion without a corresponding decrease in accuracy. Overall, the proposed method provides a comprehensive framework for evaluating the compliance of hand-gesture-based Human–Machine Interfaces with target performance specifications related to specific application contexts.
Open AccessPerformance Measurement of Gesture-Based Human–Machine Interfaces Within eXtended Reality Head-Mounted Displays
This paper proposes a method for measuring the performance of Human–Machine Interfaces based on hand-gesture recognition, implemented within eXtended Reality Head-Mounted Displays. The proposed method leverages a systematic approach, enabling performance measurement in compliance with the Guide to the Expression of Uncertainty in Measurement. As an initial step, a testbed is developed, comprising a series of icons accommodated within the field of view of the eXtended Reality Head-Mounted Display considered. Each icon must be selected through a cue-guided task using the hand gestures under evaluation. Multiple selection cycles involving different individuals are conducted to derive suitable performance metrics. These metrics are derived considering the specific parameters characterizing the hand gestures, as well as the uncertainty contributions arising from intra- and inter-individual variability in the measured quantity values. As a case study, the eXtended Reality Head-Mounted Display Microsoft HoloLens 2 and the finger-tapping gesture were investigated. Without compromising generality, the obtained results show that the proposed method can provide valuable insights into performance trends across individuals and gesture parameters. Moreover, the statistical analyses employed can determine whether increased individual familiarity with the Human–Machine Interface results in faster task completion without a corresponding decrease in accuracy. Overall, the proposed method provides a comprehensive framework for evaluating the compliance of hand-gesture-based Human–Machine Interfaces with target performance specifications related to specific application contexts.
- Open Access
- 22 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 17630-17651
A General Framework for Closed Loop Negative Feedback Multivariable Physiological Control Systems: Existence, Uniqueness, and Stability of Homeostatic Equilibrium Points
The study of homeostatic equilibrium is a key concern in several fields, from physiology and biology to medicine and biomedical engineering. Control theory approaches can provide effective strategies to model physiological control systems, helping in understanding the dynamics of bio- and physio-logical regulation processes. However, the intrinsic complexity of living systems makes it difficult to identify unified biomodels that can represent a wide variety of physiological systems. In this context, the present work proposes a general framework to model the dynamics and describe the behavior of a wide class of multivariable physiological control systems, from the molecular to the whole-organ scale. The framework adopts a structure based on a closed-loop topology taking into account multiple inputs and outputs and with the negative feedback action intrinsically embedded within the model. The development of such a general model has at least three important repercussions: the first concerns the possibility of better understanding the basic mechanisms common to many physiological systems; the second is to develop a common theoretical framework to enable effective approaches to the analysis and design of synthetic biological control systems; finally, the investigation of the structural properties of the model in a general context, allows a guided and simplified application to specific cases. To this regard, in this paper, the existence, possible uniqueness and stability properties of the homeostatic equilibrium points of the general model are investigated; the theoretical framework is then illustrated through two real-world case-studies: (i) the PI3K/AKT/mTOR pathway nonlinear dynamics, a critical regulator of cellular growth, proliferation, and survival; (ii) the control mechanism of the neuromuscular stretch reflex, among the prime triggers implicated in postural control. Results proved the capability of the proposed framework to capture the intricate dynamics of multivariable physiological systems at different scales, highlighting the existence of asymptotically stable homeostatic equilibrium and allowing the study of the impact of transmission delays on the system’s stability. At the best of authors’ knowledge, following the paper [1] where monovariable systems where dealt with, the proposed methodology is the first attempt to represent and investigate homeostasis from the molecular up to systemic level by exploiting a unified multivariable biomodeling architecture, which makes it a novel approach to understanding homeostatic control from a broader perspective.
- 22 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 17630-17651
Open AccessA General Framework for Closed Loop Negative Feedback Multivariable Physiological Control Systems: Existence, Uniqueness, and Stability of Homeostatic Equilibrium Points
The study of homeostatic equilibrium is a key concern in several fields, from physiology and biology to medicine and biomedical engineering. Control theory approaches can provide effective strategies to model physiological control systems, helping in understanding the dynamics of bio- and physio-logical regulation processes. However, the intrinsic complexity of living systems makes it difficult to identify unified biomodels that can represent a wide variety of physiological systems. In this context, the present work proposes a general framework to model the dynamics and describe the behavior of a wide class of multivariable physiological control systems, from the molecular to the whole-organ scale. The framework adopts a structure based on a closed-loop topology taking into account multiple inputs and outputs and with the negative feedback action intrinsically embedded within the model. The development of such a general model has at least three important repercussions: the first concerns the possibility of better understanding the basic mechanisms common to many physiological systems; the second is to develop a common theoretical framework to enable effective approaches to the analysis and design of synthetic biological control systems; finally, the investigation of the structural properties of the model in a general context, allows a guided and simplified application to specific cases. To this regard, in this paper, the existence, possible uniqueness and stability properties of the homeostatic equilibrium points of the general model are investigated; the theoretical framework is then illustrated through two real-world case-studies: (i) the PI3K/AKT/mTOR pathway nonlinear dynamics, a critical regulator of cellular growth, proliferation, and survival; (ii) the control mechanism of the neuromuscular stretch reflex, among the prime triggers implicated in postural control. Results proved the capability of the proposed framework to capture the intricate dynamics of multivariable physiological systems at different scales, highlighting the existence of asymptotically stable homeostatic equilibrium and allowing the study of the impact of transmission delays on the system’s stability. At the best of authors’ knowledge, following the paper [1] where monovariable systems where dealt with, the proposed methodology is the first attempt to represent and investigate homeostasis from the molecular up to systemic level by exploiting a unified multivariable biomodeling architecture, which makes it a novel approach to understanding homeostatic control from a broader perspective.
- Open Access
- 5 December 2024
- Published by Elsevier in Measurement
- Vol. 243
A method for the metrological characterization of eye- and head-tracking interfaces for human–machine interaction through eXtended Reality head-mounted displays
- 5 December 2024
- Published by Elsevier in Measurement
- Vol. 243
Open AccessA method for the metrological characterization of eye- and head-tracking interfaces for human–machine interaction through eXtended Reality head-mounted displays
- Open Access
- 21 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (19) , 31054-31061
A Novel Measurement Method for Performance Assessment of Hands-Free, XR-Based Human–Machine Interfaces
This paper presents an innovative measurement method for assessing the information transfer performance of hands-free Human-Machine Interfaces (HMIs) based on eXtended Reality (XR) technology. The proposed method primarily involves the design and implementation of a dedicated XR environment, which serves as a testbed for data acquisition. Following this, an experimental campaign is conducted, involving multiple acquisition cycles for different individuals. Finally, the proposed method enables the extraction of two primary metrics, namely Selection Accuracy and Information Transfer Rate (ITR), indicative of the potential of the considered HMIs to transfer information. These metrics account for both intra-individual and inter-individual variability within the HMIs, thus providing a metrologically sound assessment of performance. The proposed method is validated through a practical case study. Three NHMIs are considered: Eye-Tracking, Head-Tracking, and Brain-Computer Interfaces (BCIs) based on Steady-State Visually Evoked Potentials (SSVEPs), as they allow hands-free interactions solely through visual observation. Without loss of generality, Microsoft HoloLens 2 and Unicorn Hybrid Black were used as XR and BCI platforms, respectively. The experimental findings obtained from eight healthy individuals allowed a comparative analysis of the performance of the three distinct HMIs, facilitating a better understanding of which interface might be more robust for a given application scenario. Overall, the proposed method represents a reliable performance assessment of innovative HMIs. This becomes increasingly significant considering the evolution of wearable HMIs and the current lack of comprehensive strategies for their characterization.
- 21 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (19) , 31054-31061
Open AccessA Novel Measurement Method for Performance Assessment of Hands-Free, XR-Based Human–Machine Interfaces
This paper presents an innovative measurement method for assessing the information transfer performance of hands-free Human-Machine Interfaces (HMIs) based on eXtended Reality (XR) technology. The proposed method primarily involves the design and implementation of a dedicated XR environment, which serves as a testbed for data acquisition. Following this, an experimental campaign is conducted, involving multiple acquisition cycles for different individuals. Finally, the proposed method enables the extraction of two primary metrics, namely Selection Accuracy and Information Transfer Rate (ITR), indicative of the potential of the considered HMIs to transfer information. These metrics account for both intra-individual and inter-individual variability within the HMIs, thus providing a metrologically sound assessment of performance. The proposed method is validated through a practical case study. Three NHMIs are considered: Eye-Tracking, Head-Tracking, and Brain-Computer Interfaces (BCIs) based on Steady-State Visually Evoked Potentials (SSVEPs), as they allow hands-free interactions solely through visual observation. Without loss of generality, Microsoft HoloLens 2 and Unicorn Hybrid Black were used as XR and BCI platforms, respectively. The experimental findings obtained from eight healthy individuals allowed a comparative analysis of the performance of the three distinct HMIs, facilitating a better understanding of which interface might be more robust for a given application scenario. Overall, the proposed method represents a reliable performance assessment of innovative HMIs. This becomes increasingly significant considering the evolution of wearable HMIs and the current lack of comprehensive strategies for their characterization.
- Open Access
Infrared Thermography for Real-Time Assessment of the Effectiveness of Scoliosis Braces
This work proposes an innovative method, based on the use of low-cost infrared thermography (IRT) instrumentation, to assess in real time the effectiveness of scoliosis braces. Establishing the effectiveness of scoliosis braces means deciding whether the pressure exerted by the brace on the patient’s back is adequate for the intended therapeutic purpose. Traditionally, the evaluation of brace effectiveness relies on empirical, qualitative assessments carried out by orthopedists during routine follow-up examinations. Hence, it heavily depends on the expertise of the orthopedists involved. In the state of the art, the only objective methods used to confirm orthopedists’ opinions are based on the evaluation of how scoliosis progresses over time, often exposing people to ionizing radiation. To address these limitations, the method proposed in this work aims to provide a real-time, objective assessment of the effectiveness of scoliosis braces in a non-harmful way. This is achieved by exploiting the thermoelastic effect and correlating temperature changes on the patient’s back with the mechanical pressure exerted by the braces. A system based on this method is implemented and then validated through an experimental study on 21 patients conducted at an accredited orthopedic center. The experimental results demonstrate a classification accuracy slightly below 70% in discriminating between adequate and inadequate pressure, which is an encouraging result for further advancement in view of the clinical use of such systems in orthopedic centers.
Open AccessInfrared Thermography for Real-Time Assessment of the Effectiveness of Scoliosis Braces
This work proposes an innovative method, based on the use of low-cost infrared thermography (IRT) instrumentation, to assess in real time the effectiveness of scoliosis braces. Establishing the effectiveness of scoliosis braces means deciding whether the pressure exerted by the brace on the patient’s back is adequate for the intended therapeutic purpose. Traditionally, the evaluation of brace effectiveness relies on empirical, qualitative assessments carried out by orthopedists during routine follow-up examinations. Hence, it heavily depends on the expertise of the orthopedists involved. In the state of the art, the only objective methods used to confirm orthopedists’ opinions are based on the evaluation of how scoliosis progresses over time, often exposing people to ionizing radiation. To address these limitations, the method proposed in this work aims to provide a real-time, objective assessment of the effectiveness of scoliosis braces in a non-harmful way. This is achieved by exploiting the thermoelastic effect and correlating temperature changes on the patient’s back with the mechanical pressure exerted by the braces. A system based on this method is implemented and then validated through an experimental study on 21 patients conducted at an accredited orthopedic center. The experimental results demonstrate a classification accuracy slightly below 70% in discriminating between adequate and inadequate pressure, which is an encouraging result for further advancement in view of the clinical use of such systems in orthopedic centers.
- Open Access
Broadband Power Line Communication in Railway Traction Lines: A Survey
Power line communication (PLC) is a technology that exploits existing electrical transmission and distribution networks as guiding structures for electromagnetic signal propagation. This facilitates low-rate data transmission for signaling and control operations. As the demand in terms of data rate has greatly increased in the last years, the attention paid to broadband PLC (BPLC) has also greatly increased. This concept also extended to railways as broadband traction power line communication (BTPLC), aiming to offer railway operators an alternative data network in areas where other technologies are lacking. However, BTPLC implementation faces challenges due to varying operating scenarios like urban, rural, and galleries. Hence, ensuring coverage and service continuity demands the suitable characterization of the communication channel. In this regard, the scientific literature, which is an indicator of the body of knowledge related to BTPLC systems, is definitely poor if compared to that addressed to BPLC systems installed on the electrical transmission and distribution network. The relative papers dealing with BTPLC systems and focusing on the characterization of the communication channel show some theoretical approaches and, rarely, measurements guidelines and experimental results. In addition, to the best of the author’s knowledge, there are no surveys that comprehensively address these aspects. To compensate for this lack of information, a survey of the state of the art concerning BTPLC systems and the measurement methods that assist their installation, assessment, and maintenance is presented. The primary goal is to provide the interested readers with a thorough understanding of the matter and identify the current research gaps, in order to drive future research towards the most significant issues.
Open AccessBroadband Power Line Communication in Railway Traction Lines: A Survey
Power line communication (PLC) is a technology that exploits existing electrical transmission and distribution networks as guiding structures for electromagnetic signal propagation. This facilitates low-rate data transmission for signaling and control operations. As the demand in terms of data rate has greatly increased in the last years, the attention paid to broadband PLC (BPLC) has also greatly increased. This concept also extended to railways as broadband traction power line communication (BTPLC), aiming to offer railway operators an alternative data network in areas where other technologies are lacking. However, BTPLC implementation faces challenges due to varying operating scenarios like urban, rural, and galleries. Hence, ensuring coverage and service continuity demands the suitable characterization of the communication channel. In this regard, the scientific literature, which is an indicator of the body of knowledge related to BTPLC systems, is definitely poor if compared to that addressed to BPLC systems installed on the electrical transmission and distribution network. The relative papers dealing with BTPLC systems and focusing on the characterization of the communication channel show some theoretical approaches and, rarely, measurements guidelines and experimental results. In addition, to the best of the author’s knowledge, there are no surveys that comprehensively address these aspects. To compensate for this lack of information, a survey of the state of the art concerning BTPLC systems and the measurement methods that assist their installation, assessment, and maintenance is presented. The primary goal is to provide the interested readers with a thorough understanding of the matter and identify the current research gaps, in order to drive future research towards the most significant issues.