Douglas D. Silin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Douglas D. Silin has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Annabella Shewarega
Department of Radiology and Biomedical Imaging, Yale University School of Medicine, 333 Cedar St, New Haven, CT 06520, USA
1 shared publication Michelle N. Maneevese
Section of Interventional Radiology, Department of Radiology and Biomedical Imaging, Yale University School of Medicine, New Haven, CT
1 shared publication- Rohil Malpani
Department of Orthopaedics and Rehabilitation, Yale School of Medicine, New Haven, CT
1 shared publication Stephanie L. Silin
Department of Biomedical Engineering, University of Wisconsin, Madison, WI
1 shared publicationTaylor M. Powell
Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, USA
1 shared publication
Latest Publications
- Open Access
- 26 October 2023
- Published by Springer Nature in CVIR Endovascular
- Vol. 6 (1) , 1-6
Protrieve sheath utilization for capturing supra-filter thrombus during a retrieval of thrombosed and embedded IVC filter
Background: Inferior vena cava (IVC) filters, while effective in preventing pulmonary embolism, can increase the risk of IVC thrombosis. IVC filter (IVCF) thrombosis can result from emboli getting trapped within the filter, extension of deep vein thrombosis (DVT), or the device’s inherent thrombogenicity causing in situ thrombosis. This condition can cause noticeable clinical symptoms and complicate the removal of the filter due to the potential for thromboembolism, often resulting in temporary filters remaining unextracted. This case report highlights a novel approach employed to mitigate the risk of thromboembolism during the procedure by capturing mobilized thrombus proximally to the entrapped IVCF. Case presentation: A 54-year-old woman with a complex medical history including cerebral palsy, Crohn’s disease, and transfusion-dependent iron-deficiency anemia experienced a pulmonary embolism. Due to failed anticoagulation therapy resulting in gastrointestinal bleeding and high transfusion requirements, she underwent placement of an IVCF as a preventive measure against recurrent pulmonary embolism. Three years later, the patient presented with lower extremity swelling and a sudden decline in hemoglobin levels. Diagnostic imaging revealed adherent nonocclusive thrombus within and above the indwelling IVCF. Utilizing the novel Protrieve sheath with the self-expandable Nitinol funnel, successful endovascular removal of the embedded IVCF and adherent thrombus was performed, while mitigating the risk of intraprocedural pulmonary embolism. Conclusions: The successful intraprocedural trapping and removal of mobilized thrombus from the IVCF removal was achieved using the Protrieve sheath and Nitinol funnel. This approach provides a promising solution to reduce the risk of embolization during the removal of thrombosed IVCFs, potentially outweighing the complications associated with filter removal.
- 26 October 2023
- Published by Springer Nature in CVIR Endovascular
- Vol. 6 (1) , 1-6
Open AccessProtrieve sheath utilization for capturing supra-filter thrombus during a retrieval of thrombosed and embedded IVC filter
Background: Inferior vena cava (IVC) filters, while effective in preventing pulmonary embolism, can increase the risk of IVC thrombosis. IVC filter (IVCF) thrombosis can result from emboli getting trapped within the filter, extension of deep vein thrombosis (DVT), or the device’s inherent thrombogenicity causing in situ thrombosis. This condition can cause noticeable clinical symptoms and complicate the removal of the filter due to the potential for thromboembolism, often resulting in temporary filters remaining unextracted. This case report highlights a novel approach employed to mitigate the risk of thromboembolism during the procedure by capturing mobilized thrombus proximally to the entrapped IVCF. Case presentation: A 54-year-old woman with a complex medical history including cerebral palsy, Crohn’s disease, and transfusion-dependent iron-deficiency anemia experienced a pulmonary embolism. Due to failed anticoagulation therapy resulting in gastrointestinal bleeding and high transfusion requirements, she underwent placement of an IVCF as a preventive measure against recurrent pulmonary embolism. Three years later, the patient presented with lower extremity swelling and a sudden decline in hemoglobin levels. Diagnostic imaging revealed adherent nonocclusive thrombus within and above the indwelling IVCF. Utilizing the novel Protrieve sheath with the self-expandable Nitinol funnel, successful endovascular removal of the embedded IVCF and adherent thrombus was performed, while mitigating the risk of intraprocedural pulmonary embolism. Conclusions: The successful intraprocedural trapping and removal of mobilized thrombus from the IVCF removal was achieved using the Protrieve sheath and Nitinol funnel. This approach provides a promising solution to reduce the risk of embolization during the removal of thrombosed IVCFs, potentially outweighing the complications associated with filter removal.
- 1 October 2021
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 32 (10) , 1503-1505
External Compression Displacement of Bowel to Facilitate Safe Needle Passage: A New Tool in the Armamentarium
- 1 October 2021
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 32 (10) , 1503-1505
External Compression Displacement of Bowel to Facilitate Safe Needle Passage: A New Tool in the Armamentarium