Jule Bender
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jule Bender has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Axel Loewe
Institute of Biomedical Engineering Karlsruhe Institute of Technology (KIT) Karlsruhe Germany
2 shared publications Benjamin Winkler
Physikalisch-Technische Bundesanstalt, National Metrology Institute, Berlin, Germany
1 shared publicationClaudia Nagel
Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
1 shared publication- Cristian Barrios Espinosa
Institute of Biomedical Engineering Karlsruhe Institute of Technology (KIT) Karlsruhe Germany
1 shared publication - Gernot Plank
Gottfried Schatz Research Center, Division of Medical Physics and Biophysics, Medical University of Graz, Graz, Austria
1 shared publication - Job Stoks
Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center+, Maastricht, The Netherlands
1 shared publication
Latest Publications
- Open Access
Wilson’s Central Terminal Changes Location on the Body Surface During the P-Wave: Why Precordial Leads Might Not Be What We Think
Background and Aims: Clinical interpretation of the precordial leads V1-V6 assumes that Wilson’s central terminal (WCT) has a fixed anatomical location. Consequently, a positive signal corresponds to electrical activation spreading from WCT towards the respective electrode, and vice versa. However, the location of WCT has never been systematically investigated. Yet, a better understanding of WCT location could improve the interpretation of the precordial leads. This work aims to characterize the spatial expansion and location of the physical WCT i.e., the electrical potential defined by the WCT, during the P-wave on the body surface. Methods: An intensive analysis of body surface potential maps (BSPMs) during atrial depolarization in an in silico patient cohort and clinical data was conducted. Results: During the P-wave, the location of WCT was not stationary but the spatial extent and location varied across time as well as across individuals. Four distinct spatial patterns of WCT distribution on the body surface were identified in silico, and three of these were found in the clinical cohort. WCT signals agreed with BSPM signals at commonly assumed positions of WCT only for a small fraction of the P-wave. Conclusion: The spatial extension and location of WCT changes during the P-wave and thus should be considered when interpreting the precordial leads. Translational perspective: This study highlighted that the spatial extent and location of Wilson’s central terminal (WCT) on the body surface change during the P-wave. Variability in time as well as across individuals suggest that assumptions on a fixed WCT location, such as for the precordial leads, should be treated with caution.
Open AccessWilson’s Central Terminal Changes Location on the Body Surface During the P-Wave: Why Precordial Leads Might Not Be What We Think
Background and Aims: Clinical interpretation of the precordial leads V1-V6 assumes that Wilson’s central terminal (WCT) has a fixed anatomical location. Consequently, a positive signal corresponds to electrical activation spreading from WCT towards the respective electrode, and vice versa. However, the location of WCT has never been systematically investigated. Yet, a better understanding of WCT location could improve the interpretation of the precordial leads. This work aims to characterize the spatial expansion and location of the physical WCT i.e., the electrical potential defined by the WCT, during the P-wave on the body surface. Methods: An intensive analysis of body surface potential maps (BSPMs) during atrial depolarization in an in silico patient cohort and clinical data was conducted. Results: During the P-wave, the location of WCT was not stationary but the spatial extent and location varied across time as well as across individuals. Four distinct spatial patterns of WCT distribution on the body surface were identified in silico, and three of these were found in the clinical cohort. WCT signals agreed with BSPM signals at commonly assumed positions of WCT only for a small fraction of the P-wave. Conclusion: The spatial extension and location of WCT changes during the P-wave and thus should be considered when interpreting the precordial leads. Translational perspective: This study highlighted that the spatial extent and location of Wilson’s central terminal (WCT) on the body surface change during the P-wave. Variability in time as well as across individuals suggest that assumptions on a fixed WCT location, such as for the precordial leads, should be treated with caution.
- Open Access
- 8 August 2023
- Published by Springer Nature in Scientific Data
- Vol. 10 (1) , 1-19
MedalCare-XL: 16,900 healthy and pathological synthetic 12 lead ECGs from electrophysiological simulations
Mechanistic cardiac electrophysiology models allow for personalized simulations of the electrical activity in the heart and the ensuing electrocardiogram (ECG) on the body surface. As such, synthetic signals possess known ground truth labels of the underlying disease and can be employed for validation of machine learning ECG analysis tools in addition to clinical signals. Recently, synthetic ECGs were used to enrich sparse clinical data or even replace them completely during training leading to improved performance on real-world clinical test data. We thus generated a novel synthetic database comprising a total of 16,900 12 lead ECGs based on electrophysiological simulations equally distributed into healthy control and 7 pathology classes. The pathological case of myocardial infraction had 6 sub-classes. A comparison of extracted features between the virtual cohort and a publicly available clinical ECG database demonstrated that the synthetic signals represent clinical ECGs for healthy and pathological subpopulations with high fidelity. The ECG database is split into training, validation, and test folds for development and objective assessment of novel machine learning algorithms.
- 8 August 2023
- Published by Springer Nature in Scientific Data
- Vol. 10 (1) , 1-19
Open AccessMedalCare-XL: 16,900 healthy and pathological synthetic 12 lead ECGs from electrophysiological simulations
Mechanistic cardiac electrophysiology models allow for personalized simulations of the electrical activity in the heart and the ensuing electrocardiogram (ECG) on the body surface. As such, synthetic signals possess known ground truth labels of the underlying disease and can be employed for validation of machine learning ECG analysis tools in addition to clinical signals. Recently, synthetic ECGs were used to enrich sparse clinical data or even replace them completely during training leading to improved performance on real-world clinical test data. We thus generated a novel synthetic database comprising a total of 16,900 12 lead ECGs based on electrophysiological simulations equally distributed into healthy control and 7 pathology classes. The pathological case of myocardial infraction had 6 sub-classes. A comparison of extracted features between the virtual cohort and a publicly available clinical ECG database demonstrated that the synthetic signals represent clinical ECGs for healthy and pathological subpopulations with high fidelity. The ECG database is split into training, validation, and test folds for development and objective assessment of novel machine learning algorithms.