Georgia Georgostathi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Georgia Georgostathi has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Bingqing Zhang
Department of Biomedical and Health Informatics, Children’s Hospital of Philadelphia, Data Science and Biostatistics Unit, Philadelphia, PA
2 shared publications - Charles Dean Kurth
Department of Anesthesiology and Critical Care Medicine, University of Pennsylvania Perelman School of Medicine and the Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania
2 shared publications - Ian Yuan
Department of Anesthesiology and Critical Care Medicine, The Children’s Hospital of Philadelphia and the Perelman School of Medicine, University of Pennsylvania, Philadelphia, USA
2 shared publications - Shih-Shan Lang
Division of Neurosurgery, Children’s Hospital of Philadelphia, Philadelphia, USA
2 shared publications - Adam Richter
Vagelos Integrated Program in Energy Research, University of Pennsylvania, Philadelphia, USA
1 shared publication - Alexis A. Topjian
Department of Anesthesiology and Critical Care Medicine, Children’s Hospital of Philadelphia, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA
1 shared publication
Latest Publications
- 8 May 2024
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 141 (2) , 353-364
Electroencephalographic Indices for Clinical Endpoints during Propofol Anesthesia in Infants: An Early-phase Propofol Biomarker-finding Study
Background: Unlike expired sevoflurane concentration, propofol lacks a biomarker for its brain effect site concentration, leading to dosing imprecision particularly in infants. Electroencephalography monitoring can serve as a biomarker for propofol effect site concentration, yet proprietary electroencephalography indices are not validated in infants. The authors evaluated spectral edge frequency (SEF95) as a propofol anesthesia biomarker in infants. It was hypothesized that the SEF95 targets will vary for different clinical stimuli and an inverse relationship existed between SEF95 and propofol plasma concentration. Methods: This prospective study enrolled infants (3 to 12 months) to determine the SEF95 ranges for three clinical endpoints of anesthesia (consciousness-pacifier placement, pain-electrical nerve stimulation, and intubation-laryngoscopy) and correlation between SEF95 and propofol plasma concentration at steady state. Dixon’s up–down method was used to determine target SEF95 for each clinical endpoint. Centered isotonic regression determined the dose–response function of SEF95 where 50% and 90% of infants (ED50 and ED90) did not respond to the clinical endpoint. Linear mixed-effect model determined the association of propofol plasma concentration and SEF95. Results: Of 49 enrolled infants, 44 evaluable (90%) showed distinct SEF95 for endpoints: pacifier (ED50, 21.4 Hz; ED90, 19.3 Hz), electrical stimulation (ED50, 12.6 Hz; ED90, 10.4 Hz), and laryngoscopy (ED50, 8.5 Hz; ED90, 5.2 Hz). From propofol 0.5 to 6 μg/ml, a 1-Hz SEF95 increase was linearly correlated to a 0.24 (95% CI, 0.19 to 0.29; P < 0.001) μg/ml decrease in plasma propofol concentration (marginal R 2 = 0.55). Conclusions: SEF95 can be a biomarker for propofol anesthesia depth in infants, potentially improving dosing accuracy and utilization of propofol anesthesia in this population. Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New:
- 8 May 2024
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 141 (2) , 353-364
Electroencephalographic Indices for Clinical Endpoints during Propofol Anesthesia in Infants: An Early-phase Propofol Biomarker-finding Study
Background: Unlike expired sevoflurane concentration, propofol lacks a biomarker for its brain effect site concentration, leading to dosing imprecision particularly in infants. Electroencephalography monitoring can serve as a biomarker for propofol effect site concentration, yet proprietary electroencephalography indices are not validated in infants. The authors evaluated spectral edge frequency (SEF95) as a propofol anesthesia biomarker in infants. It was hypothesized that the SEF95 targets will vary for different clinical stimuli and an inverse relationship existed between SEF95 and propofol plasma concentration. Methods: This prospective study enrolled infants (3 to 12 months) to determine the SEF95 ranges for three clinical endpoints of anesthesia (consciousness-pacifier placement, pain-electrical nerve stimulation, and intubation-laryngoscopy) and correlation between SEF95 and propofol plasma concentration at steady state. Dixon’s up–down method was used to determine target SEF95 for each clinical endpoint. Centered isotonic regression determined the dose–response function of SEF95 where 50% and 90% of infants (ED50 and ED90) did not respond to the clinical endpoint. Linear mixed-effect model determined the association of propofol plasma concentration and SEF95. Results: Of 49 enrolled infants, 44 evaluable (90%) showed distinct SEF95 for endpoints: pacifier (ED50, 21.4 Hz; ED90, 19.3 Hz), electrical stimulation (ED50, 12.6 Hz; ED90, 10.4 Hz), and laryngoscopy (ED50, 8.5 Hz; ED90, 5.2 Hz). From propofol 0.5 to 6 μg/ml, a 1-Hz SEF95 increase was linearly correlated to a 0.24 (95% CI, 0.19 to 0.29; P < 0.001) μg/ml decrease in plasma propofol concentration (marginal R 2 = 0.55). Conclusions: SEF95 can be a biomarker for propofol anesthesia depth in infants, potentially improving dosing accuracy and utilization of propofol anesthesia in this population. Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New:
- 18 October 2023
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 38 (3) , 591-602
Quantitative electroencephalogram in term neonates under different sleep states
Electroencephalogram (EEG) can be used to assess depth of consciousness, but interpreting EEG can be challenging, especially in neonates whose EEG undergo rapid changes during the perinatal course. EEG can be processed into quantitative EEG (QEEG), but limited data exist on the range of QEEG for normal term neonates during wakefulness and sleep, baseline information that would be useful to determine changes during sedation or anesthesia. We aimed to determine the range of QEEG in neonates during awake, active sleep and quiet sleep states, and identified the ones best at discriminating between the three states. Normal neonatal EEG from 37 to 46 weeks were analyzed and classified as awake, quiet sleep, or active sleep. After processing and artifact removal, total power, power ratio, coherence, entropy, and spectral edge frequency (SEF) 50 and 90 were calculated. Descriptive statistics were used to summarize the QEEG in each of the three states. Receiver operating characteristic (ROC) curves were used to assess discriminatory ability of QEEG. 30 neonates were analyzed. QEEG were different between awake vs asleep states, but similar between active vs quiet sleep states. Entropy beta, delta2 power %, coherence delta2, and SEF50 were best at discriminating awake vs active sleep. Entropy beta had the highest AUC-ROC ≥ 0.84. Entropy beta, entropy delta1, theta power %, and SEF50 were best at discriminating awake vs quiet sleep. All had AUC-ROC ≥ 0.78. In active sleep vs quiet sleep, theta power % had highest AUC-ROC > 0.69, lower than the other comparisons. We determined the QEEG range in healthy neonates in different states of consciousness. Entropy beta and SEF50 were best at discriminating between awake and sleep states. QEEG were not as good at discriminating between quiet and active sleep. In the future, QEEG with high discriminatory power can be combined to further improve ability to differentiate between states of consciousness.
- 18 October 2023
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 38 (3) , 591-602
Quantitative electroencephalogram in term neonates under different sleep states
Electroencephalogram (EEG) can be used to assess depth of consciousness, but interpreting EEG can be challenging, especially in neonates whose EEG undergo rapid changes during the perinatal course. EEG can be processed into quantitative EEG (QEEG), but limited data exist on the range of QEEG for normal term neonates during wakefulness and sleep, baseline information that would be useful to determine changes during sedation or anesthesia. We aimed to determine the range of QEEG in neonates during awake, active sleep and quiet sleep states, and identified the ones best at discriminating between the three states. Normal neonatal EEG from 37 to 46 weeks were analyzed and classified as awake, quiet sleep, or active sleep. After processing and artifact removal, total power, power ratio, coherence, entropy, and spectral edge frequency (SEF) 50 and 90 were calculated. Descriptive statistics were used to summarize the QEEG in each of the three states. Receiver operating characteristic (ROC) curves were used to assess discriminatory ability of QEEG. 30 neonates were analyzed. QEEG were different between awake vs asleep states, but similar between active vs quiet sleep states. Entropy beta, delta2 power %, coherence delta2, and SEF50 were best at discriminating awake vs active sleep. Entropy beta had the highest AUC-ROC ≥ 0.84. Entropy beta, entropy delta1, theta power %, and SEF50 were best at discriminating awake vs quiet sleep. All had AUC-ROC ≥ 0.78. In active sleep vs quiet sleep, theta power % had highest AUC-ROC > 0.69, lower than the other comparisons. We determined the QEEG range in healthy neonates in different states of consciousness. Entropy beta and SEF50 were best at discriminating between awake and sleep states. QEEG were not as good at discriminating between quiet and active sleep. In the future, QEEG with high discriminatory power can be combined to further improve ability to differentiate between states of consciousness.