Victor Ungurean
Victor Ungurean has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Dimitriy Kondrashov
St. Mary’s Medical Center
3 shared publications - Alexander Rosinski
St. Mary’s Medical Center, San Francisco Orthopaedic Residency Program, San Francisco, CA
2 shared publications - Jeremi M. Leasure
The Taylor Collaboration, San Francisco, California
2 shared publications - Khalid Odeh
San Francisco Orthopaedic Residency Program, St. Mary’s Medical Center, San Francisco, California
2 shared publications Adam Schlauch
Department of Orthopaedic Surgery, SF Orthopaedic Residency Program, St. Mary’s Medical Center, San Francisco, CA
1 shared publicationAmit S. Piple
The Taylor Collaboration, San Francisco, CA
1 shared publication
Latest Publications
- Open Access
- 31 March 2025
- Published by The Korean Spinal Neurosurgery Society in Neurospine
- Vol. 22 (1) , 173-184
Loss of Mass and Surface Topography in 3-Dimensional-Printed Solid Titanium Cages Upon Impaction: An In Vitro Model
Objective: There is increased use of 3-dimensional (3D)-printing for manufacturing of interbody cages to create microscale surface features that promote bone formation. Those features may be vulnerable to abrasion and/or delamination during cage impaction. Our objective was to quantify loss of mass and changes in surface topography of 3D-printed titanium interbody cages due to surgical impaction.Methods: Eight surfaces of four 3D-printed titanium modular interbody fusion cages were tested. The cages were impacted into the Sawbones model with compression preload of either 200N or 400N using a guided 1-lb (0.45 kg) drop weight. Mass and surface roughness parameters of each endplate were recorded and compared for differences.Results: Significant weight loss was observed for the superior endplate group and for both 200N and 400N preloads. For pooled data comparison, significant postimpaction decreases were observed for mean roughness, root-mean-squared roughness, mean roughness depth, and total height of roughness profile. No significant differences were observed for profile skewness and kurtosis. There were significant changes in almost all roughness parameters in the anterior region of the cage postimpaction with significant changes in 2 out of 6 parameters in the middle, posterior, and central regions postimpaction.Conclusion: Three-dimensional-printed titanium interbody fusion cages underwent loss of mass and alteration in surface topography during benchtop testing replicating physiologic conditions. There was an endplate- and region-specific postimpaction change in roughness parameters. The anterior surface experienced the largest change in surface parameters postimpaction. Our results have implications for future cage design and pre-approval testing of 3D-printed implants.
- 31 March 2025
- Published by The Korean Spinal Neurosurgery Society in Neurospine
- Vol. 22 (1) , 173-184
Open AccessLoss of Mass and Surface Topography in 3-Dimensional-Printed Solid Titanium Cages Upon Impaction: An In Vitro Model
Objective: There is increased use of 3-dimensional (3D)-printing for manufacturing of interbody cages to create microscale surface features that promote bone formation. Those features may be vulnerable to abrasion and/or delamination during cage impaction. Our objective was to quantify loss of mass and changes in surface topography of 3D-printed titanium interbody cages due to surgical impaction.Methods: Eight surfaces of four 3D-printed titanium modular interbody fusion cages were tested. The cages were impacted into the Sawbones model with compression preload of either 200N or 400N using a guided 1-lb (0.45 kg) drop weight. Mass and surface roughness parameters of each endplate were recorded and compared for differences.Results: Significant weight loss was observed for the superior endplate group and for both 200N and 400N preloads. For pooled data comparison, significant postimpaction decreases were observed for mean roughness, root-mean-squared roughness, mean roughness depth, and total height of roughness profile. No significant differences were observed for profile skewness and kurtosis. There were significant changes in almost all roughness parameters in the anterior region of the cage postimpaction with significant changes in 2 out of 6 parameters in the middle, posterior, and central regions postimpaction.Conclusion: Three-dimensional-printed titanium interbody fusion cages underwent loss of mass and alteration in surface topography during benchtop testing replicating physiologic conditions. There was an endplate- and region-specific postimpaction change in roughness parameters. The anterior surface experienced the largest change in surface parameters postimpaction. Our results have implications for future cage design and pre-approval testing of 3D-printed implants.
- 27 March 2023
- Published by Wolters Kluwer Health in Spine
- Vol. 49 (8) , 553-560
Are all Cages Created Equal? Analysis of Cervical Cage Malfunctions Using FDA MAUDE Database
Study Design.: Retrospective case series. Objective.: To characterize failure rates of cervical cages based on manufacturer and design characteristics using the nationwide database of reported malfunctions. Background.: The Food and Drug Administration (FDA) aims to ensure the safety and efficacy of cervical interbody implants postimplantation; however, intraoperative malfunctions may be overlooked. Materials and Methods.: The FDA’s Manufacturer and User Facility Device Experience database was queried for reports of cervical cage device malfunctions from 2012 to 2021. Each report was categorized based on the failure type, implant design, and manufacturer. Two market analyses were performed. First, “failure-to-market share indices” were generated by dividing the number of failures per year for each implant material by its yearly US market share in cervical spine fusion. Second, “failure-to-revenue indices” were calculated by dividing the total number of failures per year for each manufacturer by their approximate yearly revenue from spinal implants in the US. Outlier analysis was performed to generate a threshold value above which failure rates were defined as greater than the normal index. Results.: In total, 1336 entries were identified, and 1225 met the inclusion criteria. Of these, 354 (28.9%) were cage breakages, 54 (4.4%) were cage migrations, 321 (26.2%) were instrumentation-related failures, 301 (24.6%) were assembly failures, and 195 (15.9%) were screw failures. Poly-ether-ether-ketone implants had higher failure by market share indices for both migration and breakage compared with titanium. Upon manufacturer market analysis, Seaspine, Zimmer-Biomet, K2M, and LDR exceeded the failure threshold. Conclusion.: The most common cause of implant malfunction was breakage. Poly-ether-ether-ketone cages were more likely to break and migrate compared with titanium ones. Many of these implant failures occurred intraoperatively during instrumentation, which underscores the need for FDA evaluation of these implants and their accompanying instrumentation under the appropriate loading conditions before commercial approval.
- 27 March 2023
- Published by Wolters Kluwer Health in Spine
- Vol. 49 (8) , 553-560
Are all Cages Created Equal? Analysis of Cervical Cage Malfunctions Using FDA MAUDE Database
Study Design.: Retrospective case series. Objective.: To characterize failure rates of cervical cages based on manufacturer and design characteristics using the nationwide database of reported malfunctions. Background.: The Food and Drug Administration (FDA) aims to ensure the safety and efficacy of cervical interbody implants postimplantation; however, intraoperative malfunctions may be overlooked. Materials and Methods.: The FDA’s Manufacturer and User Facility Device Experience database was queried for reports of cervical cage device malfunctions from 2012 to 2021. Each report was categorized based on the failure type, implant design, and manufacturer. Two market analyses were performed. First, “failure-to-market share indices” were generated by dividing the number of failures per year for each implant material by its yearly US market share in cervical spine fusion. Second, “failure-to-revenue indices” were calculated by dividing the total number of failures per year for each manufacturer by their approximate yearly revenue from spinal implants in the US. Outlier analysis was performed to generate a threshold value above which failure rates were defined as greater than the normal index. Results.: In total, 1336 entries were identified, and 1225 met the inclusion criteria. Of these, 354 (28.9%) were cage breakages, 54 (4.4%) were cage migrations, 321 (26.2%) were instrumentation-related failures, 301 (24.6%) were assembly failures, and 195 (15.9%) were screw failures. Poly-ether-ether-ketone implants had higher failure by market share indices for both migration and breakage compared with titanium. Upon manufacturer market analysis, Seaspine, Zimmer-Biomet, K2M, and LDR exceeded the failure threshold. Conclusion.: The most common cause of implant malfunction was breakage. Poly-ether-ether-ketone cages were more likely to break and migrate compared with titanium ones. Many of these implant failures occurred intraoperatively during instrumentation, which underscores the need for FDA evaluation of these implants and their accompanying instrumentation under the appropriate loading conditions before commercial approval.
- 1 July 2021
- Published by Wolters Kluwer Health in JBJS Reviews
- Vol. 9 (7)
Alternatives to Traditional Pedicle Screws for Posterior Fixation of the Degenerative Lumbar Spine
Background: Traditional pedicle screws are currently the gold standard to achieve stable 3-column fixation of the degenerative lumbar spine. However, there are cases in which pedicle screw fixation may not be ideal. Due to their starting point lateral to the pars interarticularis, pedicle screws require a relatively wide dissection along with a medialized trajectory directed toward the centrally located neural elements and prevertebral vasculature. In addition, low bone mineral density remains a major risk factor for pedicle screw loosening, pullout, and pseudarthrosis. The purpose of this article is to review the indications, advantages, disadvantages, and complications associated with posterior fixation techniques of the degenerative lumbar spine beyond the traditional pedicle screws. Methods: Comprehensive literature searches of the PubMed, Scopus, and Web of Science databases were performed for 5 methods of posterior spinal fixation, including (1) cortical bone trajectory (CBT) screws, (2) transfacet screws, (3) translaminar screws, (4) spinous process plates, and (5) fusion mass screws and hooks. Articles that had been published between January 1, 1990, and January 1, 2020, were considered. Non-English-language articles and studies involving fixation of the cervical or thoracic spine were excluded from our review. Results: After reviewing over 1,700 articles pertaining to CBT and non-pedicular fixation techniques, a total of 284 articles met our inclusion criteria. CBT and transfacet screws require less-extensive exposure and paraspinal muscle dissection compared with traditional pedicle screws and may therefore reduce blood loss, postoperative pain, and length of hospital stay. In addition, several methods of non-pedicular fixation such as translaminar and fusion mass screws have trajectories that are directed away from or posterior to the spinal canal, potentially decreasing the risk of neurologic injury. CBT, transfacet, and fusion mass screws can also be used as salvage techniques when traditional pedicle screw constructs fail. Conclusions: CBT and non-pedicular fixation may be preferred in certain lumbar degenerative cases, particularly among patients with osteoporosis. Limitations of non-pedicular techniques include their reliance on intact posterior elements and the lack of 3-column fixation of the spine. As a result, transfacet and translaminar screws are infrequently used as the primary method of fixation. CBT, transfacet, and translaminar screws are effective in augmenting interbody fixation and have been shown to significantly improve fusion rates and clinical outcomes compared with stand-alone anterior lumbar interbody fusion. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 1 July 2021
- Published by Wolters Kluwer Health in JBJS Reviews
- Vol. 9 (7)
Alternatives to Traditional Pedicle Screws for Posterior Fixation of the Degenerative Lumbar Spine
Background: Traditional pedicle screws are currently the gold standard to achieve stable 3-column fixation of the degenerative lumbar spine. However, there are cases in which pedicle screw fixation may not be ideal. Due to their starting point lateral to the pars interarticularis, pedicle screws require a relatively wide dissection along with a medialized trajectory directed toward the centrally located neural elements and prevertebral vasculature. In addition, low bone mineral density remains a major risk factor for pedicle screw loosening, pullout, and pseudarthrosis. The purpose of this article is to review the indications, advantages, disadvantages, and complications associated with posterior fixation techniques of the degenerative lumbar spine beyond the traditional pedicle screws. Methods: Comprehensive literature searches of the PubMed, Scopus, and Web of Science databases were performed for 5 methods of posterior spinal fixation, including (1) cortical bone trajectory (CBT) screws, (2) transfacet screws, (3) translaminar screws, (4) spinous process plates, and (5) fusion mass screws and hooks. Articles that had been published between January 1, 1990, and January 1, 2020, were considered. Non-English-language articles and studies involving fixation of the cervical or thoracic spine were excluded from our review. Results: After reviewing over 1,700 articles pertaining to CBT and non-pedicular fixation techniques, a total of 284 articles met our inclusion criteria. CBT and transfacet screws require less-extensive exposure and paraspinal muscle dissection compared with traditional pedicle screws and may therefore reduce blood loss, postoperative pain, and length of hospital stay. In addition, several methods of non-pedicular fixation such as translaminar and fusion mass screws have trajectories that are directed away from or posterior to the spinal canal, potentially decreasing the risk of neurologic injury. CBT, transfacet, and fusion mass screws can also be used as salvage techniques when traditional pedicle screw constructs fail. Conclusions: CBT and non-pedicular fixation may be preferred in certain lumbar degenerative cases, particularly among patients with osteoporosis. Limitations of non-pedicular techniques include their reliance on intact posterior elements and the lack of 3-column fixation of the spine. As a result, transfacet and translaminar screws are infrequently used as the primary method of fixation. CBT, transfacet, and translaminar screws are effective in augmenting interbody fixation and have been shown to significantly improve fusion rates and clinical outcomes compared with stand-alone anterior lumbar interbody fusion. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 1 May 2020
- Published by Wolters Kluwer Health in JBJS Reviews
- Vol. 8 (5) , e0150
Non-Pedicular Fixation Techniques for the Treatment of Spinal Deformity
Background: In recent years, the use of pedicle screws has become the gold standard for achieving stable, 3-column fixation of the spine. However, pedicle screw placement may not always be ideal, such as in adolescent idiopathic scoliosis, because of pedicle morphology. An understanding of the alternatives to pedicle screw fixation is therefore important in the treatment of patients with spinal deformity. The purpose of this article is to review the indications, advantages, disadvantages, and complications associated with non-pedicular fixation techniques of the thoracolumbar spine. Methods: Comprehensive literature searches of PubMed, Scopus, and Web of Science databases were performed for 10 methods of non-pedicular fixation. Articles published between January 1, 1990, and June 1, 2019, were considered. Non-English-language articles and studies involving fixation of the cervical spine were excluded from our review. Results: After reviewing >1,600 titles and abstracts pertaining to non-pedicular fixation, a total of 213 articles met our inclusion criteria. Non-pedicular fixation may be preferred in certain cases of spinal deformity and may provide stronger fixation in osteoporotic bone. The use of non-pedicular fixation techniques is often limited by the inability to place multilevel constructs on intact posterior elements. Additionally, some methods of non-pedicular fixation, such as spinous process tethering, primarily have utility for the end of constructs to minimize junctional problems. Conclusions: Pedicle screws remain the anchor of choice in spinal deformity surgery because of their ability to engage all 3 columns of the spine and provide safe correction in all 3 planes. Nevertheless, non-pedicular fixation may be useful in cases in which pedicle screw placement is extremely difficult. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 1 May 2020
- Published by Wolters Kluwer Health in JBJS Reviews
- Vol. 8 (5) , e0150
Non-Pedicular Fixation Techniques for the Treatment of Spinal Deformity
Background: In recent years, the use of pedicle screws has become the gold standard for achieving stable, 3-column fixation of the spine. However, pedicle screw placement may not always be ideal, such as in adolescent idiopathic scoliosis, because of pedicle morphology. An understanding of the alternatives to pedicle screw fixation is therefore important in the treatment of patients with spinal deformity. The purpose of this article is to review the indications, advantages, disadvantages, and complications associated with non-pedicular fixation techniques of the thoracolumbar spine. Methods: Comprehensive literature searches of PubMed, Scopus, and Web of Science databases were performed for 10 methods of non-pedicular fixation. Articles published between January 1, 1990, and June 1, 2019, were considered. Non-English-language articles and studies involving fixation of the cervical spine were excluded from our review. Results: After reviewing >1,600 titles and abstracts pertaining to non-pedicular fixation, a total of 213 articles met our inclusion criteria. Non-pedicular fixation may be preferred in certain cases of spinal deformity and may provide stronger fixation in osteoporotic bone. The use of non-pedicular fixation techniques is often limited by the inability to place multilevel constructs on intact posterior elements. Additionally, some methods of non-pedicular fixation, such as spinous process tethering, primarily have utility for the end of constructs to minimize junctional problems. Conclusions: Pedicle screws remain the anchor of choice in spinal deformity surgery because of their ability to engage all 3 columns of the spine and provide safe correction in all 3 planes. Nevertheless, non-pedicular fixation may be useful in cases in which pedicle screw placement is extremely difficult. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.