MKMojtaba Karbalaee

Mojtaba Karbalaee

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mojtaba Karbalaee has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    EvoMed‐Net: A Sequential Multi‐CNN Ensemble for Brain Tumor Analysis in MRI

    by Barat Barati, Hashem Khanbabaei, Nahid Chegeni, Abbas Rezaeian, Elahe Ahmadi, Maryam Erfaninejad, Seyed Ali Mousavi, Sima Hashemi, Seyed Mojtaba Karbalaee, Jamshid Mashhadi

    Improving patient outcomes depends on the early and precise detection of brain tumors. This study proposes EvoMed‐Net, a sequential ensemble framework comprising four independent convolutional neural networks—ZFNet, AlexNet, VGG16, and ResNet50—to automatically classify and segment brain tumors using magnetic resonance imaging (MRI). The first dataset included 8199 MRI scans for multiclass tumor type classification, while a second dataset of 3064 scans with corresponding masks was used for tumor detection and segmentation. Results from the four CNN models were combined using decision‐level fusion techniques such as majority voting and probabilistic averaging to enhance diagnostic robustness. The individual CNN models achieved precision, recall, and F1 scores ranging from 0.96 to 0.97, while the ensemble approach achieved an overall classification accuracy of 99%. The proposed averaged aggregation consensus (AAC) strategy generated a more stable ensemble decision through probability aggregation and improved classification consistency. Notable class separability was observed in ZFNet, and ResNet50 obtained the highest overlap scores in the segmentation task. The integrated detection–segmentation framework demonstrated reliable capability in accurately delineating small tumor regions and reducing manual intervention, advancing toward intelligent, noninvasive diagnostic systems. These findings confirm that the sequential integration of models provides a reliable and accurate method for MRI‐based brain tumor assessment, serving as an effective decision support tool in clinical diagnostics.

  • Open Access

    Preferred radiological modalities in the diagnosis and management of kidney and urinary tract stones; a systematic review

    by Ranin Haghighi, Jalal Rezaei, Fatemeh Khaleghi, Mohammad Hamidi Madani, Hussein Soleimantabar, Mahsa Norouzi, Mojtaba Karbalaee, Zahra Askari, Roozbeh Roohinezhad, Rasoul Jafari Arismani

    Introduction: Kidney and urinary tract stones are a common health concern, with a rising global incidence and significant impact on patient quality of life. Accurate diagnosis and effective management of these stones rely heavily on radiological imaging modalities. This systematic review aimed to synthesize the existing literature on preferred radiological modalities for diagnosing and managing kidney and urinary tract stones, focusing on their diagnostic accuracy, clinical efficacy, and impact on treatment outcomes. Methods: This systematic review was conducted based on PRISMA guidelines to evaluate preferred radiological modalities for diagnosing and managing kidney and urinary tract stones. A comprehensive literature search across multiple databases, including PubMed, Embase, Cochrane Library, Scopus, and Google Scholar, was conducted up to July 2024, using a comprehensive set of MeSH keywords. Quality assessment was performed using the STROBE checklist, with medium and high-quality studies considered acceptable. Data extraction by two independent reviewers captured essential information, with discrepancies resolved through discussion or consultation with a third reviewer. Results: The results of 12 included studies in this review indicated that, while CT scans are the most accurate imaging modality for diagnosing kidney and urinary tract stones, ultrasound presents a viable alternative due to its lower radiation exposure. Most studies reported ultrasound sensitivities above 55% and specificities over 95% compared to CT, although some studies noted significantly lower sensitivities. Additionally, X-ray imaging showed limitations, with sensitivities of only 46% to 57%, particularly for smaller stones. Conclusion: This study highlights that while CT scans are the gold standard for diagnosing kidney and urinary tract stones due to their accuracy, ultrasound presents a valuable alternative as an initial diagnostic tool, primarily because of its lower radiation exposure, which enhances patient safety, especially for those needing repeated imaging. Furthermore, the limitations of X-ray imaging in detecting smaller stones caution against its exclusive use. The review also emphasizes the importance of balancing diagnostic accuracy with safety when considering high-dose versus low-dose CT scans. Registration: This study has been compiled based on the PRISMA checklist, and its protocol was registered on the PROSPERO (ID: CRD42024579547) and Research Registry (UIN: reviewregistry1873) websites.


  • Open Access

    A Cross-sectional Study on Power Density of Non-ionizing Radiation and the Incidence of Related Adverse Health Effects in Zabol

    by Majid Valizade, Omolbanin Sargazi Aval, Mojtaba Karbalaee

    Introduction: Increased use of wireless devices and networks such as mobile phones has increased exposure to non-ionizing radiation. Since wireless devices are a distinct part of the ongoing technology, the benefits of applications must outweigh the associated risks so that the developments can take place. In this questionnaire-based study, we aimed to evaluate the effects of non-ionizing radiation from mobile phone base transceiver station (BTS) antennae on the Zabol inhabitants’ health. Methods: In this study, 349 volunteers (186 men and 163 women) inhabiting in Zabol, Iran, were asked to complete a standardized questionnaire from April 2019 to June 2021. The questionnaire included information about age, sex, education, time of residence, and the emergence of symptoms such as cardiovascular problems, weight loss, depression, sleep disturbance, nervousness, and hearing disturbances. The power density of non-ionizing radiation in the living place of the volunteers was measured by an Electro Smog Meter (TES-92 TES Instruments Taiwan). Results: Results showed that the frequency of complaints increased by enhancing the power density for most of the studied symptoms, and in some cases (e.g., irritability, P<0.05 and lowering of libido, P<0.05), the increase was significant with at least P600 μW/m2 (P<0.05). Conclusion: It is suggested that inhabitants should not live in locations where the power density is higher than 600 μW/m2 to minimize the risk of radiation-induced symptoms.