Jan Hinrichsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jan Hinrichsen has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Silvia Budday
Institute of Continuum Mechanics and Biomechanics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Egerlandstraße 5, Erlangen, 91058, Germany
4 shared publications Arnd Doerfler
Department of Neuroradiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen , Germany
2 shared publicationsPaul Steinmann
Institute of Applied Mechanics Friedrich‐Alexander‐Universität Erlangen‐Nürnberg 91058 Erlangen Germany
2 shared publications- Aldo Roberto Boccaccini
Institute of Biomaterials University of Erlangen‐Nuremberg Erlangen Germany
1 shared publication - Anahita Ahmadi Soufivand
Institute of Continuum Mechanics and Biomechanics, Department of Mechanical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, 90762 Fürth, Germany
1 shared publication Ben Fabry
Department of Physics Friedrich‐Alexander‐Universität Erlangen‐Nürnberg 91058 Erlangen Germany
1 shared publication
Latest Publications
- Open Access
The Mechanical Fingerprint of Hippocampal Sclerosis Linking Neuronal Cell Loss and Gliosis to Tissue Stiffness
Hippocampal sclerosis (HS) is the most common pathology in drug-resistant temporal lobe epilepsy (TLE). However, clinical diagnosis, prevalent epileptogenicity, and drug drug-resistance in individuals with HS remain an ongoing challenge demanding multidisciplinary research efforts. In this study, we examined the mechanical properties of neurosurgically en bloc resected HS specimens (n=8) ex vivo under compression, tension, and torsional shear. We fitted a two-term Ogden hyperelastic model to the measured mechanical responses to quantify nonlinear mechanical tissue properties. The resulting parameters revealed higher strain stiffening under compression in HS compared to hippocampus obtained post mortem (n=7). The distinction was most noticeable in the large-strain regime, which has important implications for using mechanical tissue properties as valuable diagnostic biomarker. Furthermore, we correlated the tissue microstructure with mechanical parameters. We trained a deep-learning histopathology classifier to detect and classify neurons and glial cells from hematoxylin-stained whole slide images (WSI). We identified a strong association between the small-strain stiffness (shear modulus µ ) and the overall cell density as well as the glial cell density. The negative relationship between the neuron-to-glia ratio and shear modulus is consistent with the hypothesis that neuronal cell loss and gliosis drives tissue stiffening, respectively. Magnetic resonance imaging (MRI) analysis of the specimens confirmed the previously reported negative association between MRI-derived fractional anisotropy and shear modulus µ . Taken together, our study establishes a direct link between tissue mechanics and microstructure, suggesting nonlinear continuum mechanics models as promising new tools for clinical diagnosis and novel research strategies.
Open AccessThe Mechanical Fingerprint of Hippocampal Sclerosis Linking Neuronal Cell Loss and Gliosis to Tissue Stiffness
Hippocampal sclerosis (HS) is the most common pathology in drug-resistant temporal lobe epilepsy (TLE). However, clinical diagnosis, prevalent epileptogenicity, and drug drug-resistance in individuals with HS remain an ongoing challenge demanding multidisciplinary research efforts. In this study, we examined the mechanical properties of neurosurgically en bloc resected HS specimens (n=8) ex vivo under compression, tension, and torsional shear. We fitted a two-term Ogden hyperelastic model to the measured mechanical responses to quantify nonlinear mechanical tissue properties. The resulting parameters revealed higher strain stiffening under compression in HS compared to hippocampus obtained post mortem (n=7). The distinction was most noticeable in the large-strain regime, which has important implications for using mechanical tissue properties as valuable diagnostic biomarker. Furthermore, we correlated the tissue microstructure with mechanical parameters. We trained a deep-learning histopathology classifier to detect and classify neurons and glial cells from hematoxylin-stained whole slide images (WSI). We identified a strong association between the small-strain stiffness (shear modulus µ ) and the overall cell density as well as the glial cell density. The negative relationship between the neuron-to-glia ratio and shear modulus is consistent with the hypothesis that neuronal cell loss and gliosis drives tissue stiffening, respectively. Magnetic resonance imaging (MRI) analysis of the specimens confirmed the previously reported negative association between MRI-derived fractional anisotropy and shear modulus µ . Taken together, our study establishes a direct link between tissue mechanics and microstructure, suggesting nonlinear continuum mechanics models as promising new tools for clinical diagnosis and novel research strategies.
- Open Access
Towards patient-specific biomechanical human brain models
Reliable characterization of spatial variations in brain tissue stiffness is essential for predictive biomechanical modeling, yet most current methods rely on coarse regional parameter assignments based on invasive mechanical testing. In this study, we propose a new approach to obtain subject-specific mechanical properties at voxel resolution from in vivo diffusion tensor magnetic resonance imaging (DTI) based on a linear regression between the fractional anisotropy (FA) from DTI and experimentally measured stiffness values. To assess how such heterogeneity in mechanical properties influences simulated brain deformation, we construct a finite element model based on two material parameterizations of the same human brain: one employing nine anatomically defined regions, each with uniform material parameters, and another in which the shear modulus is assigned voxel-wise on the corresponding FA value. Applying this FA-stiffness mapping yields a smoothly varying mechanical property distribution that better captures local microstructural differences not represented by region-wise parameterizations. Both parameterizations are subjected to an identical atrophy-driven loading scenario. They exhibit comparable overall volume loss, but diverge in regional behavior. The voxel-resolved parameterization predicts more pronounced ventricular expansion and differs in the displacement and stretch distributions, indicating that variability in stiffness can alter local predicted responses even when global outcomes appear similar. This work presents a pipeline for estimating individualized mechanical properties directly from imaging protocols that are routinely performed on patients, with important implications for brain biomechanics. While the approach depends on a simplified linear FA-stiffness relation and assumes isotropic constitutive behavior, it provides a framework for integrating imaging-based microstructure into subject-specific simulations. Future validation against in vivo or experimental deformation data is needed to determine the fidelity and clinical utility of FA-derived stiffness fields.
Open AccessTowards patient-specific biomechanical human brain models
Reliable characterization of spatial variations in brain tissue stiffness is essential for predictive biomechanical modeling, yet most current methods rely on coarse regional parameter assignments based on invasive mechanical testing. In this study, we propose a new approach to obtain subject-specific mechanical properties at voxel resolution from in vivo diffusion tensor magnetic resonance imaging (DTI) based on a linear regression between the fractional anisotropy (FA) from DTI and experimentally measured stiffness values. To assess how such heterogeneity in mechanical properties influences simulated brain deformation, we construct a finite element model based on two material parameterizations of the same human brain: one employing nine anatomically defined regions, each with uniform material parameters, and another in which the shear modulus is assigned voxel-wise on the corresponding FA value. Applying this FA-stiffness mapping yields a smoothly varying mechanical property distribution that better captures local microstructural differences not represented by region-wise parameterizations. Both parameterizations are subjected to an identical atrophy-driven loading scenario. They exhibit comparable overall volume loss, but diverge in regional behavior. The voxel-resolved parameterization predicts more pronounced ventricular expansion and differs in the displacement and stretch distributions, indicating that variability in stiffness can alter local predicted responses even when global outcomes appear similar. This work presents a pipeline for estimating individualized mechanical properties directly from imaging protocols that are routinely performed on patients, with important implications for brain biomechanics. While the approach depends on a simplified linear FA-stiffness relation and assumes isotropic constitutive behavior, it provides a framework for integrating imaging-based microstructure into subject-specific simulations. Future validation against in vivo or experimental deformation data is needed to determine the fidelity and clinical utility of FA-derived stiffness fields.
- Open Access
- 5 December 2025
- Published by Wiley in Advanced Healthcare Materials
- Vol. 15 (9) , e03052
Compression‐Tension‐Asymmetry and Stiffness Nonlinearity of Collagen‐Matrigel Composite Hydrogels
Collagen type I hydrogels, which self‐assemble into 3D fiber networks, are commonly used for cell culture and tissue engineering applications. Collagen hydrogels replicate the nonlinear stress–strain relationship of collagenous tissue under extension. However, they buckle and soften under compression, whereas natural tissue exhibits significant stiffening due to the presence of cells and other matrix components. To more closely mimic the mechanical properties of natural tissue, varying concentrations of the basement membrane extract Matrigel are added to collagen. The stress–strain relationship of the resulting composite hydrogels is then analyzed under compression, tension, and shear. It is found that the addition of Matrigel increases the stiffness and reduces the compression‐tension asymmetry. This can be explained by a reduced degree of freedom for collagen fiber buckling due to the constraints imposed by the surrounding fine‐meshed Matrigel network. Consistent with this explanation, it is found that the collapse of composite hydrogels under uniaxial strain decreases with increasing concentration of Matrigel and other filler materials, such as alginate. Taken together, by adjusting the ratio of Matrigel to collagen, the mechanical compression‐tension asymmetry and nonlinearity of composite hydrogels can be tuned to more closely mimic natural tissue and tailor cell behavior.
- 5 December 2025
- Published by Wiley in Advanced Healthcare Materials
- Vol. 15 (9) , e03052
Open AccessCompression‐Tension‐Asymmetry and Stiffness Nonlinearity of Collagen‐Matrigel Composite Hydrogels
Collagen type I hydrogels, which self‐assemble into 3D fiber networks, are commonly used for cell culture and tissue engineering applications. Collagen hydrogels replicate the nonlinear stress–strain relationship of collagenous tissue under extension. However, they buckle and soften under compression, whereas natural tissue exhibits significant stiffening due to the presence of cells and other matrix components. To more closely mimic the mechanical properties of natural tissue, varying concentrations of the basement membrane extract Matrigel are added to collagen. The stress–strain relationship of the resulting composite hydrogels is then analyzed under compression, tension, and shear. It is found that the addition of Matrigel increases the stiffness and reduces the compression‐tension asymmetry. This can be explained by a reduced degree of freedom for collagen fiber buckling due to the constraints imposed by the surrounding fine‐meshed Matrigel network. Consistent with this explanation, it is found that the collapse of composite hydrogels under uniaxial strain decreases with increasing concentration of Matrigel and other filler materials, such as alginate. Taken together, by adjusting the ratio of Matrigel to collagen, the mechanical compression‐tension asymmetry and nonlinearity of composite hydrogels can be tuned to more closely mimic natural tissue and tailor cell behavior.
- Open Access
- 28 December 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 163, 106871
Tuning the mechanical properties of alginate dialdehyde–gelatin (ADA–GEL) bioinks for bioprinting approaches by varying the degree of oxidation
- 28 December 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 163, 106871
Open AccessTuning the mechanical properties of alginate dialdehyde–gelatin (ADA–GEL) bioinks for bioprinting approaches by varying the degree of oxidation
- Open Access
- 9 August 2023
- Published by Elsevier in Journal of the Mechanics and Physics of Solids
- Vol. 180
Automated discovery of interpretable hyperelastic material models for human brain tissue with EUCLID
- 9 August 2023
- Published by Elsevier in Journal of the Mechanics and Physics of Solids
- Vol. 180
Open AccessAutomated discovery of interpretable hyperelastic material models for human brain tissue with EUCLID