Songbai Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Songbai Wang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Binfeng Yin
School of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China
3 shared publications - Teng Zhou
School of Mechanical and Electrical Engineering, Hainan University, Haikou 570228, China
3 shared publications Xinhua Wan
School of Mechanical Engineering, Yangzhou University, Yangzhou, 225127, China
3 shared publicationsChangcheng Qian
School of Mechanical Engineering, Yangzhou University, Yangzhou, China
2 shared publications- A. S. M. Muhtasim Fuad Sohan
School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, SA 5005, Australia
1 shared publication - Liuyong Shi
Affiliation School of Mechanical and Electrical Engineering, Hainan University, Haikou, China
1 shared publication
Latest Publications
- 9 August 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 239, 115586
A portable automated chip for simultaneous rapid point-of-care testing of multiple β-agonists
- 9 August 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 239, 115586
A portable automated chip for simultaneous rapid point-of-care testing of multiple β-agonists
- Open Access
- 4 October 2021
- Published by Frontiers Media SA in Frontiers in Chemistry
- Vol. 9
Point-of-Care Testing for Multiple Cardiac Markers Based on a Snail-Shaped Microfluidic Chip
Existing methods for detecting cardiac markers are difficult to be applied in point-of-care testing (POCT) due to complex operation, long time consumption, and low sensitivity. Here, we report a snail-shaped microfluidic chip (SMC) for the multiplex detection of cTnI, CK-MB, and Myo with high sensitivity and a short detection time. The SMC consists of a sandwich structure: a channel layer with a mixer and reaction zone, a reaction layer coated with capture antibodies, and a base layer. The opening or closing of the microchannels is realized by controlling the downward movement of the press-type mechanical valve. The chemiluminescence method was used as a signal readout, and the experimental conditions were optimized. SMC could detect cTnI, CK-MB, and Myo at concentrations as low as 1.02, 1.37, and 4.15. The SMC will be a promising platform for a simultaneous determination of multianalytes and shows a potential application in POCT.
- 4 October 2021
- Published by Frontiers Media SA in Frontiers in Chemistry
- Vol. 9
Open AccessPoint-of-Care Testing for Multiple Cardiac Markers Based on a Snail-Shaped Microfluidic Chip
Existing methods for detecting cardiac markers are difficult to be applied in point-of-care testing (POCT) due to complex operation, long time consumption, and low sensitivity. Here, we report a snail-shaped microfluidic chip (SMC) for the multiplex detection of cTnI, CK-MB, and Myo with high sensitivity and a short detection time. The SMC consists of a sandwich structure: a channel layer with a mixer and reaction zone, a reaction layer coated with capture antibodies, and a base layer. The opening or closing of the microchannels is realized by controlling the downward movement of the press-type mechanical valve. The chemiluminescence method was used as a signal readout, and the experimental conditions were optimized. SMC could detect cTnI, CK-MB, and Myo at concentrations as low as 1.02, 1.37, and 4.15. The SMC will be a promising platform for a simultaneous determination of multianalytes and shows a potential application in POCT.
- Open Access
- 28 May 2021
- Published by Frontiers Media SA in Frontiers in Chemistry
- Vol. 9
A Microfluidic Chip-Based MRS Immunosensor for Biomarker Detection via Enzyme-Mediated Nanoparticle Assembly
Conventional immunoassay methods have their common defects, such as tedious processing steps and inadequate sensitivity, in detecting whole blood. To overcome the above problems, we report a microfluidic chip–based magnetic relaxation switching (MRS) immunosensor via enzyme-mediated nanoparticles to simplify operation and amplify the signal in detecting whole blood samples. In the silver mirror reaction with catalase (CAT) as the catalyst, H2O2 can effectively control the production of Ag NPs. The amount of Ag NPs formed further affects the degree of aggregation of magnetic nanoparticles (MNPS), which gives rise to the changes of transverse relaxation time (T2). Both sample addition and reagent reaction are carried out in the microfluidic chip, thereby saving time and reagent consumption. We also successfully apply the sensor to detect alpha-fetoprotein (AFP) in real samples with a satisfied limit of detection (LOD = 0.56 ng/ml), which is superior to the conventional ELISA.
- 28 May 2021
- Published by Frontiers Media SA in Frontiers in Chemistry
- Vol. 9
Open AccessA Microfluidic Chip-Based MRS Immunosensor for Biomarker Detection via Enzyme-Mediated Nanoparticle Assembly
Conventional immunoassay methods have their common defects, such as tedious processing steps and inadequate sensitivity, in detecting whole blood. To overcome the above problems, we report a microfluidic chip–based magnetic relaxation switching (MRS) immunosensor via enzyme-mediated nanoparticles to simplify operation and amplify the signal in detecting whole blood samples. In the silver mirror reaction with catalase (CAT) as the catalyst, H2O2 can effectively control the production of Ag NPs. The amount of Ag NPs formed further affects the degree of aggregation of magnetic nanoparticles (MNPS), which gives rise to the changes of transverse relaxation time (T2). Both sample addition and reagent reaction are carried out in the microfluidic chip, thereby saving time and reagent consumption. We also successfully apply the sensor to detect alpha-fetoprotein (AFP) in real samples with a satisfied limit of detection (LOD = 0.56 ng/ml), which is superior to the conventional ELISA.