Dongxian Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dongxian Peng has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Pingping Wang
Obstetrics and Gynecology Center, Department of Gynecology, Zhujiang Hospital, Southern Medical University, Guangzhou, China
4 shared publications- Zhengyong Liu
Sun Yat-sen University
4 shared publications Jie Chen
Obstetrics and Gynecology Center, Department of Gynecology, Zhujiang Hospital, Southern Medical University, Guangzhou, China
3 shared publicationsXuemei Huang
Obstetrics and Gynecology Center, Department of Gynecology, Zhujiang Hospital, Southern Medical University, Guangzhou, China
3 shared publicationsJie Huang
Obstetrics and Gynecology Center, Department of Gynecology Zhujiang Hospital, Southern Medical University Guangzhou China
2 shared publicationsYuxin Huang
Obstetrics and Gynecology Center, Department of Gynecology, Zhujiang Hospital, Southern Medical University, Guangzhou, China
2 shared publications
Latest Publications
- Open Access
- 1 September 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (09) , 1-14
Intelligent laparoscopic grasper with hybrid neural networks for real-time vascular detection in minimally invasive surgery
SignificanceWe address the challenge of inadequate force feedback in laparoscopic surgery, which increases the risk of vessel injury. By integrating fiber Bragg grating (FBG) sensors with a laparoscopic grasper and employing a convolutional neural network combined with long short-term memory (CNN-LSTM) algorithm, this approach enables real-time, accurate vessel identification, potentially reducing surgical complications.AimLaparoscopic surgery is often hindered by inadequate force feedback, especially in complex scenarios involving tumor invasion and pelvic-abdominal adhesion, leading to challenges in locating blood vessels and an increased risk of vessel injury. Thus, it is desirable to develop a laparoscopic system capable of distinguishing the location and type of the vessels during surgery, which requires a compact and highly sensitive sensor integrated with a laparoscopic grasper.ApproachWe present an innovative laparoscopic grasper integrated with FBG force sensors for real-time force feedback, employing silicone and porcine vessel models to simulate varying depths and tissue coverage. The device successfully captured specific vessel signals, which were processed through a CNN-LSTM algorithm, enabling real-time vessel identification in minimally invasive surgery (MIS).ResultsThe intelligent laparoscopic grasper successfully obtained distinct vessel signals under varying conditions. As a result, the mean vessel gripping force for porcine vessel model III was 0.059 N under fatty tissue and 0.032 N under muscle tissue (p<0.001). The CNN-LSTM algorithm achieved a precision of 97.06% in vessel identification across different tissue coverages.ConclusionsThe FBG sensor-integrated laparoscopic grasper, assisted by the processing of the CNN-LSTM algorithm, demonstrated the ability to identify vessels ex vivo across different models. This technology holds potential for real-time and accurate vessel identification during MIS, which could significantly reduce the occurrence of unnecessary vessel injuries.
- 1 September 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (09) , 1-14
Open AccessIntelligent laparoscopic grasper with hybrid neural networks for real-time vascular detection in minimally invasive surgery
SignificanceWe address the challenge of inadequate force feedback in laparoscopic surgery, which increases the risk of vessel injury. By integrating fiber Bragg grating (FBG) sensors with a laparoscopic grasper and employing a convolutional neural network combined with long short-term memory (CNN-LSTM) algorithm, this approach enables real-time, accurate vessel identification, potentially reducing surgical complications.AimLaparoscopic surgery is often hindered by inadequate force feedback, especially in complex scenarios involving tumor invasion and pelvic-abdominal adhesion, leading to challenges in locating blood vessels and an increased risk of vessel injury. Thus, it is desirable to develop a laparoscopic system capable of distinguishing the location and type of the vessels during surgery, which requires a compact and highly sensitive sensor integrated with a laparoscopic grasper.ApproachWe present an innovative laparoscopic grasper integrated with FBG force sensors for real-time force feedback, employing silicone and porcine vessel models to simulate varying depths and tissue coverage. The device successfully captured specific vessel signals, which were processed through a CNN-LSTM algorithm, enabling real-time vessel identification in minimally invasive surgery (MIS).ResultsThe intelligent laparoscopic grasper successfully obtained distinct vessel signals under varying conditions. As a result, the mean vessel gripping force for porcine vessel model III was 0.059 N under fatty tissue and 0.032 N under muscle tissue (p<0.001). The CNN-LSTM algorithm achieved a precision of 97.06% in vessel identification across different tissue coverages.ConclusionsThe FBG sensor-integrated laparoscopic grasper, assisted by the processing of the CNN-LSTM algorithm, demonstrated the ability to identify vessels ex vivo across different models. This technology holds potential for real-time and accurate vessel identification during MIS, which could significantly reduce the occurrence of unnecessary vessel injuries.
- Open Access
- 30 January 2025
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 25 (1) , 1-13
C3AR1 as a target for preeclampsia: from bioinformatics and network pharmacology to experimental validation
Preeclampsia, characterized by hypertension and proteinuria during pregnancy, poses significant risks to both mother and fetus. The complement system’s aberrant activation, notably the C3AR1, is important to the pathogenesis of preeclampsia, although the precise mechanisms are not fully understood. Utilizing the Comparative Toxicogenomics Database (CTD) and Molecular Signatures Database (MSigDB), we identified complement system targets associated with preeclampsia and environmental pollutants. Expression validation was conducted through the Gene Expression Omnibus (GEO) database. Molecular docking predicted interactions between BPA, PFOS, and C3AR1. Immunohistochemical staining of 80 placental tissues (40 early-onset preeclampsia and 40 healthy controls) confirmed C3AR1 expression and its clinical correlation. Integrated bioinformatics analyses revealed C3AR1’s role in preeclampsia’s molecular mechanisms. Functional verification was assessed by knocking down C3AR1 in HTR-8/Svneo cells, including cell proliferation, invasion, and apoptosis. Network pharmacology established connections between pollutants and preeclampsia, with C3AR1 as a key target. Molecular docking confirmed BPA and PFOS binding to C3AR1. Reduced C3AR1 in preeclamptic placentas correlated with maternal blood pressure, and showed high diagnostic potential (AUC = 0.95). C3AR1’s involvement in preeclampsia was linked to Jak-STAT, TGF-β, and HIF-1 pathways, and associated with NK cell and M1 macrophage activity. C3AR1 knockdown in HTR-8/Svneo cells decreased proliferation and invasion, and increased apoptosis. C3AR1 expression is diminished in preeclampsia placental tissues, correlating with disease severity, suggesting its potential as a biomarker. It is crucial for cellular functions and inflammation, with future studies aiming to leverage this for novel preeclampsia treatments. Not applicable.
- 30 January 2025
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 25 (1) , 1-13
Open AccessC3AR1 as a target for preeclampsia: from bioinformatics and network pharmacology to experimental validation
Preeclampsia, characterized by hypertension and proteinuria during pregnancy, poses significant risks to both mother and fetus. The complement system’s aberrant activation, notably the C3AR1, is important to the pathogenesis of preeclampsia, although the precise mechanisms are not fully understood. Utilizing the Comparative Toxicogenomics Database (CTD) and Molecular Signatures Database (MSigDB), we identified complement system targets associated with preeclampsia and environmental pollutants. Expression validation was conducted through the Gene Expression Omnibus (GEO) database. Molecular docking predicted interactions between BPA, PFOS, and C3AR1. Immunohistochemical staining of 80 placental tissues (40 early-onset preeclampsia and 40 healthy controls) confirmed C3AR1 expression and its clinical correlation. Integrated bioinformatics analyses revealed C3AR1’s role in preeclampsia’s molecular mechanisms. Functional verification was assessed by knocking down C3AR1 in HTR-8/Svneo cells, including cell proliferation, invasion, and apoptosis. Network pharmacology established connections between pollutants and preeclampsia, with C3AR1 as a key target. Molecular docking confirmed BPA and PFOS binding to C3AR1. Reduced C3AR1 in preeclamptic placentas correlated with maternal blood pressure, and showed high diagnostic potential (AUC = 0.95). C3AR1’s involvement in preeclampsia was linked to Jak-STAT, TGF-β, and HIF-1 pathways, and associated with NK cell and M1 macrophage activity. C3AR1 knockdown in HTR-8/Svneo cells decreased proliferation and invasion, and increased apoptosis. C3AR1 expression is diminished in preeclampsia placental tissues, correlating with disease severity, suggesting its potential as a biomarker. It is crucial for cellular functions and inflammation, with future studies aiming to leverage this for novel preeclampsia treatments. Not applicable.
- Open Access
- 12 September 2024
- Published by Springer Nature in Molecular Medicine
- Vol. 30 (1) , 1-26
SIRT1-mediated deacetylation of FOXO3 enhances mitophagy and drives hormone resistance in endometrial cancer
Background: The complex interplay between Sirtuin 1 (SIRT1) and FOXO3 in endometrial cancer (EC) remains understudied. This research aims to unravel the interactions of deacetylase SIRT1 and transcription factor FOXO3 in EC, focusing on their impact on mitophagy and hormone resistance. Methods: High-throughput sequencing, cell experiments, and bioinformatics tools were employed to investigate the roles and interactions of SIRT1 and FOXO3 in EC. Co-immunoprecipitation (Co-IP) assay was used to assess the interaction between SIRT1 and FOXO3 in RL95-2 cells. Functional assays were used to assess cell viability, proliferation, migration, invasion, apoptosis, and the expression of related genes and proteins. A mouse model of EC was established to evaluate tumor growth and hormone resistance under different interventions. Immunohistochemistry and TUNEL assays were used to assess protein expression and apoptosis in tumor tissues. Results: High-throughput transcriptome sequencing revealed a close association between SIRT1, FOXO3, and EC development. Co-IP showed a protein–protein interaction between SIRT1 and FOXO3. Overexpression of SIRT1 enhanced FOXO3 deacetylation and activity, promoting BNIP3 transcription and PINK1/Parkin-mediated mitophagy, which in turn promoted cell proliferation, migration, invasion, and inhibited apoptosis in vitro, as well as increased tumor growth and hormone resistance in vivo. These findings highlighted SIRT1 as an upstream regulator and potential therapeutic target in EC. Conclusion: This study reveals a novel molecular mechanism underlying the functional relevance of SIRT1 in regulating mitophagy and hormone resistance through the deacetylation of FOXO3 in EC, thereby providing valuable insights for new therapeutic strategies.
- 12 September 2024
- Published by Springer Nature in Molecular Medicine
- Vol. 30 (1) , 1-26
Open AccessSIRT1-mediated deacetylation of FOXO3 enhances mitophagy and drives hormone resistance in endometrial cancer
Background: The complex interplay between Sirtuin 1 (SIRT1) and FOXO3 in endometrial cancer (EC) remains understudied. This research aims to unravel the interactions of deacetylase SIRT1 and transcription factor FOXO3 in EC, focusing on their impact on mitophagy and hormone resistance. Methods: High-throughput sequencing, cell experiments, and bioinformatics tools were employed to investigate the roles and interactions of SIRT1 and FOXO3 in EC. Co-immunoprecipitation (Co-IP) assay was used to assess the interaction between SIRT1 and FOXO3 in RL95-2 cells. Functional assays were used to assess cell viability, proliferation, migration, invasion, apoptosis, and the expression of related genes and proteins. A mouse model of EC was established to evaluate tumor growth and hormone resistance under different interventions. Immunohistochemistry and TUNEL assays were used to assess protein expression and apoptosis in tumor tissues. Results: High-throughput transcriptome sequencing revealed a close association between SIRT1, FOXO3, and EC development. Co-IP showed a protein–protein interaction between SIRT1 and FOXO3. Overexpression of SIRT1 enhanced FOXO3 deacetylation and activity, promoting BNIP3 transcription and PINK1/Parkin-mediated mitophagy, which in turn promoted cell proliferation, migration, invasion, and inhibited apoptosis in vitro, as well as increased tumor growth and hormone resistance in vivo. These findings highlighted SIRT1 as an upstream regulator and potential therapeutic target in EC. Conclusion: This study reveals a novel molecular mechanism underlying the functional relevance of SIRT1 in regulating mitophagy and hormone resistance through the deacetylation of FOXO3 in EC, thereby providing valuable insights for new therapeutic strategies.
- Open Access
- 20 February 2024
- Published by Springer Nature in BMC Medical Education
- Vol. 24 (1) , 1-13
An intelligent grasper to provide real-time force feedback to shorten the learning curve in laparoscopic training
Background: A lack of force feedback in laparoscopic surgery often leads to a steep learning curve to the novices and traditional training system equipped with force feedback need a high educational cost. This study aimed to use a laparoscopic grasper providing force feedback in laparoscopic training which can assist in controlling of gripping forces and improve the learning processing of the novices. Methods: Firstly, we conducted a pre-experiment to verify the role of force feedback in gripping operations and establish the safe gripping force threshold for the tasks. Following this, we proceeded with a four-week training program. Unlike the novices without feedback (Group A2), the novices receiving feedback (Group B2) underwent training that included force feedback. Finally, we completed a follow-up period without providing force feedback to assess the training effect under different conditions. Real-time force parameters were recorded and compared. Results: In the pre-experiment, we set the gripping force threshold for the tasks based on the experienced surgeons’ performance. This is reasonable as the experienced surgeons have obtained adequate skill of handling grasper. The thresholds for task 1, 2, and 3 were set as 0.731 N, 1.203 N and 0.938 N, respectively. With force feedback, the gripping force applied by the novices with feedback (Group B1) was lower than that of the novices without feedback (Group A1) (p < 0.005). During the training period, the Group B2 takes 6 trails to achieve gripping force of 0.635 N, which is lower than the threshold line, whereas the Group A2 needs 11 trails, meaning that the learning curve of Group B2 was significantly shorter than that of Group A2. Additionally, during the follow-up period, there was no significant decline in force learning, and Group B2 demonstrated better control of gripping operations. The training with force feedback received positive evaluations. Conclusion: Our study shows that using a grasper providing force feedback in laparoscopic training can help to control the gripping force and shorten the learning curve. It is anticipated that the laparoscopic grasper equipped with FBG sensor is promising to provide force feedback during laparoscopic training, which ultimately shows great potential in laparoscopic surgery.
- 20 February 2024
- Published by Springer Nature in BMC Medical Education
- Vol. 24 (1) , 1-13
Open AccessAn intelligent grasper to provide real-time force feedback to shorten the learning curve in laparoscopic training
Background: A lack of force feedback in laparoscopic surgery often leads to a steep learning curve to the novices and traditional training system equipped with force feedback need a high educational cost. This study aimed to use a laparoscopic grasper providing force feedback in laparoscopic training which can assist in controlling of gripping forces and improve the learning processing of the novices. Methods: Firstly, we conducted a pre-experiment to verify the role of force feedback in gripping operations and establish the safe gripping force threshold for the tasks. Following this, we proceeded with a four-week training program. Unlike the novices without feedback (Group A2), the novices receiving feedback (Group B2) underwent training that included force feedback. Finally, we completed a follow-up period without providing force feedback to assess the training effect under different conditions. Real-time force parameters were recorded and compared. Results: In the pre-experiment, we set the gripping force threshold for the tasks based on the experienced surgeons’ performance. This is reasonable as the experienced surgeons have obtained adequate skill of handling grasper. The thresholds for task 1, 2, and 3 were set as 0.731 N, 1.203 N and 0.938 N, respectively. With force feedback, the gripping force applied by the novices with feedback (Group B1) was lower than that of the novices without feedback (Group A1) (p < 0.005). During the training period, the Group B2 takes 6 trails to achieve gripping force of 0.635 N, which is lower than the threshold line, whereas the Group A2 needs 11 trails, meaning that the learning curve of Group B2 was significantly shorter than that of Group A2. Additionally, during the follow-up period, there was no significant decline in force learning, and Group B2 demonstrated better control of gripping operations. The training with force feedback received positive evaluations. Conclusion: Our study shows that using a grasper providing force feedback in laparoscopic training can help to control the gripping force and shorten the learning curve. It is anticipated that the laparoscopic grasper equipped with FBG sensor is promising to provide force feedback during laparoscopic training, which ultimately shows great potential in laparoscopic surgery.
- 12 January 2022
- Published by Wiley in Journal of Biophotonics
- Vol. 15 (5) , e202100331
Smart laparoscopic grasper integrated with fiber Bragg grating based tactile sensor for real‐time force feedback
Minimally invasive surgery, such as laparoscopic surgery, has developed rapidly due to its small wound, less bleeding and quick recovery. However, a lack of force feedback, which leads to tissue damage, is still unsolved. Many sensors have been used to offer force feedback but still limited by their large size, low security and high complexity. Based on the advantages of small size, high sensitivity and immunity to electromagnetic interferences, we propose a tactile sensor integrated with fiber Bragg gratings (FBGs) at the tip of laparoscopic grasper to offer real‐time force feedback in the laparoscopic surgery. The tactile sensor shows a force sensitivity of 0.076 nm/N with a repeatable accuracy of 0.118 N. A bench test is conducted in a laparoscopic training box to verify its feasibility. Test results illustrate that gripping force exerted on the laparoscopic grasper in terms of peak and standard deviation values reduce significantly for the novice subjects with force feedback compared to those without force feedback. The proposed sensor integrated at the tip of the laparoscopic grasper demonstrates a better control of the gripping force among the novice surgeons and indicates that the smart grasper can help surgeons achieve precise gripping force to reduce unnecessary tissue trauma.
- 12 January 2022
- Published by Wiley in Journal of Biophotonics
- Vol. 15 (5) , e202100331
Smart laparoscopic grasper integrated with fiber Bragg grating based tactile sensor for real‐time force feedback
Minimally invasive surgery, such as laparoscopic surgery, has developed rapidly due to its small wound, less bleeding and quick recovery. However, a lack of force feedback, which leads to tissue damage, is still unsolved. Many sensors have been used to offer force feedback but still limited by their large size, low security and high complexity. Based on the advantages of small size, high sensitivity and immunity to electromagnetic interferences, we propose a tactile sensor integrated with fiber Bragg gratings (FBGs) at the tip of laparoscopic grasper to offer real‐time force feedback in the laparoscopic surgery. The tactile sensor shows a force sensitivity of 0.076 nm/N with a repeatable accuracy of 0.118 N. A bench test is conducted in a laparoscopic training box to verify its feasibility. Test results illustrate that gripping force exerted on the laparoscopic grasper in terms of peak and standard deviation values reduce significantly for the novice subjects with force feedback compared to those without force feedback. The proposed sensor integrated at the tip of the laparoscopic grasper demonstrates a better control of the gripping force among the novice surgeons and indicates that the smart grasper can help surgeons achieve precise gripping force to reduce unnecessary tissue trauma.
- 1 January 2021
- Published by Optica Publishing Group
- p. W1D.4
Novel optical fiber tactile sensor in laparoscope for force feedback
In this paper, we presented a fiber Bragg grating (FBG) force sensor integrated at the tip of a laparoscopic grasper, which was used to offer real-time force feedback to the operators to reduce tissue damage.
- 1 January 2021
- Published by Optica Publishing Group
- p. W1D.4
Novel optical fiber tactile sensor in laparoscope for force feedback
In this paper, we presented a fiber Bragg grating (FBG) force sensor integrated at the tip of a laparoscopic grasper, which was used to offer real-time force feedback to the operators to reduce tissue damage.
- 1 February 2015
- Vol. 35 (2) , 281-3
[Lentiviral vector-mediated short hairpin RNA targeting survivin inhibits abdominal growth of human endometrium xenograft in nude mice].
To investigate the inhibitory effect of lentiviral vector-mediated short hairpin RNA targeting survivin (LV-survivin shRNA) on the growth of human endometrium xenograft in the abdominal cavity of nude mice. The endometrium xenografts from 8 women with endometriosis were injected into the peritoneal cavities of 45 nude mice. The mice were then randomly assigned to receive intraperitoneal injection of LV-survivin shRNA, pGCL-NC-GFP (negative control) or PBS (blank control). Two weeks later, the number and morphometry of endometriotic lesions were quantified and the expression of survivin protein were detected by immunohistochemistry. The formation of endometriotic lesions was significantly suppressed in mice receiving LV-survivin shRNA injection as compared with those in the two control groups (P/0.001). The mice in LV-survivin-shRNA group showed significantly down-regulated expression levels of survivin protein compared with those in the negative and blank control groups, presenting also necrosis in the endometriosis-like lesions in microscopic observation. Lentiviral vector-mediated shRNA can effectively inhibit the expression of survivin in human endometrium xengrafts and suppress the formation and growth of endometriotic lesions in the abdominal cavities of nude mice.
- 1 February 2015
- Vol. 35 (2) , 281-3
[Lentiviral vector-mediated short hairpin RNA targeting survivin inhibits abdominal growth of human endometrium xenograft in nude mice].
To investigate the inhibitory effect of lentiviral vector-mediated short hairpin RNA targeting survivin (LV-survivin shRNA) on the growth of human endometrium xenograft in the abdominal cavity of nude mice. The endometrium xenografts from 8 women with endometriosis were injected into the peritoneal cavities of 45 nude mice. The mice were then randomly assigned to receive intraperitoneal injection of LV-survivin shRNA, pGCL-NC-GFP (negative control) or PBS (blank control). Two weeks later, the number and morphometry of endometriotic lesions were quantified and the expression of survivin protein were detected by immunohistochemistry. The formation of endometriotic lesions was significantly suppressed in mice receiving LV-survivin shRNA injection as compared with those in the two control groups (P/0.001). The mice in LV-survivin-shRNA group showed significantly down-regulated expression levels of survivin protein compared with those in the negative and blank control groups, presenting also necrosis in the endometriosis-like lesions in microscopic observation. Lentiviral vector-mediated shRNA can effectively inhibit the expression of survivin in human endometrium xengrafts and suppress the formation and growth of endometriotic lesions in the abdominal cavities of nude mice.