Yanina Biondi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yanina Biondi has a total of 278 co-authors. Here are the top co-authors by number of shared publications:
- Adrian Schwenck
Institute for Astroparticle Physics, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen
3 shared publications - Frédéric Girard
McGill University
3 shared publications - Alejandro Saenz
Humboldt-Universität zu Berlin
2 shared publications - Alessandro Schwemmer
Technical University of Munich
2 shared publications - Alexander Bismark
Physik-Institut, University of Zurich, 8057 Zürich, Switzerland
2 shared publications - Alexander Marsteller
Karlsruhe Institute of Technology (KIT)
2 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , P10042
MOTION, a liquid xenon time projection chamber platform for high voltage technologies in dark matter detectors
The XLZD observatory is a next-generation liquid xenon experiment designed to search for weakly interacting massive particles (WIMPs) and other rare events using a 60–80 tonne liquid xenon time projection chamber (TPC). This detector aims to achieve sensitivity across the full WIMP parameter space down to the neutrino fog, establishing the ultimate sensitivity for this dark matter search paradigm. This unprecedented scale introduces substantial engineering challenges and pushes operation into largely unexplored regimes: the interplay between high-voltage (HV) systems, liquid xenon, and conducting materials in ultra-pure environments. To systematically investigate these challenges, we have built MOTION, a 70 kg LXe detector dedicated to understanding HV performance and electrostatic phenomena up to 200 kV (negative polarity). We describe the design and construction of the experimental infrastructure, including the cryogenic system, xenon purification and storage. MOTION enables controlled studies of dielectric breakdown in LXe, permitting systematic characterization of discharge mechanisms and their dependence on electrode geometry, surface condition, and applied voltage. The detector also facilitates investigations of field emission and photoemission from electrodes following various surface treatments, and provides a platform for validating the design of an HV feedthrough constructed from radiopure materials. The insights from these studies are essential for ensuring the operational stability, radiopurity, and scalability required for next-generation dark matter detectors.
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , P10042
Open AccessMOTION, a liquid xenon time projection chamber platform for high voltage technologies in dark matter detectors
The XLZD observatory is a next-generation liquid xenon experiment designed to search for weakly interacting massive particles (WIMPs) and other rare events using a 60–80 tonne liquid xenon time projection chamber (TPC). This detector aims to achieve sensitivity across the full WIMP parameter space down to the neutrino fog, establishing the ultimate sensitivity for this dark matter search paradigm. This unprecedented scale introduces substantial engineering challenges and pushes operation into largely unexplored regimes: the interplay between high-voltage (HV) systems, liquid xenon, and conducting materials in ultra-pure environments. To systematically investigate these challenges, we have built MOTION, a 70 kg LXe detector dedicated to understanding HV performance and electrostatic phenomena up to 200 kV (negative polarity). We describe the design and construction of the experimental infrastructure, including the cryogenic system, xenon purification and storage. MOTION enables controlled studies of dielectric breakdown in LXe, permitting systematic characterization of discharge mechanisms and their dependence on electrode geometry, surface condition, and applied voltage. The detector also facilitates investigations of field emission and photoemission from electrodes following various surface treatments, and provides a platform for validating the design of an HV feedthrough constructed from radiopure materials. The insights from these studies are essential for ensuring the operational stability, radiopurity, and scalability required for next-generation dark matter detectors.
- Open Access
- 9 July 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (7) , 1-13
Measurement of the inhomogeneity of the KATRIN tritium source electric potential by high-resolution spectroscopy of conversion electrons from $\mathbf {^{83m}}$KrPrecision spectroscopy of the electron spectrum of the tritium $$\upbeta $$ -decay near the kinematic endpoint is a direct method to determine the effective electron antineutrino mass. The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to determine this quantity with a sensitivity of better than $${0.3}{\hbox { eV}}$$ ( $$90\%$$ C.L.). An inhomogeneous electric potential in the tritium source of KATRIN can lead to distortions of the $$\upbeta $$ -spectrum, which directly impact the neutrino-mass observable. This effect can be quantified through precision spectroscopy of the conversion-electrons of co-circulated metastable $$^{83\text {m}}\text {Kr}$$ . Therefore, dedicated, several-weeks long measurement campaigns have been performed within the KATRIN data taking schedule. In this work, we infer the tritium source potential observables from these measurements, and present their implications for the neutrino-mass determination.- 9 July 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (7) , 1-13
Open AccessMeasurement of the inhomogeneity of the KATRIN tritium source electric potential by high-resolution spectroscopy of conversion electrons from $\mathbf {^{83m}}$KrPrecision spectroscopy of the electron spectrum of the tritium $$\upbeta $$ -decay near the kinematic endpoint is a direct method to determine the effective electron antineutrino mass. The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to determine this quantity with a sensitivity of better than $${0.3}{\hbox { eV}}$$ ( $$90\%$$ C.L.). An inhomogeneous electric potential in the tritium source of KATRIN can lead to distortions of the $$\upbeta $$ -spectrum, which directly impact the neutrino-mass observable. This effect can be quantified through precision spectroscopy of the conversion-electrons of co-circulated metastable $$^{83\text {m}}\text {Kr}$$ . Therefore, dedicated, several-weeks long measurement campaigns have been performed within the KATRIN data taking schedule. In this work, we infer the tritium source potential observables from these measurements, and present their implications for the neutrino-mass determination. - Top Cited Papers
- 11 April 2025
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 388 (6743) , 180-185
Direct neutrino-mass measurement based on 259 days of KATRIN data
That neutrinos carry a nonvanishing rest mass is evidence of physics beyond the Standard Model of elementary particles. Their absolute mass holds relevance in fields from particle physics to cosmology. We report on the search for the effective electron antineutrino mass with the KATRIN experiment. KATRIN performs precision spectroscopy of the tritium β-decay close to the kinematic endpoint. On the basis of the first five measurement campaigns, we derived a best-fit value of m ν 2 = − 0.14 − 0.15 + 0.13 eV 2 , resulting in an upper limit of m ν < 0.45 eV at 90% confidence level. Stemming from 36 million electrons collected in 259 measurement days, a substantial reduction of the background level, and improved systematic uncertainties, this result tightens KATRIN’s previous bound by a factor of almost two.
- 11 April 2025
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 388 (6743) , 180-185
Top Cited PapersDirect neutrino-mass measurement based on 259 days of KATRIN data
That neutrinos carry a nonvanishing rest mass is evidence of physics beyond the Standard Model of elementary particles. Their absolute mass holds relevance in fields from particle physics to cosmology. We report on the search for the effective electron antineutrino mass with the KATRIN experiment. KATRIN performs precision spectroscopy of the tritium β-decay close to the kinematic endpoint. On the basis of the first five measurement campaigns, we derived a best-fit value of m ν 2 = − 0.14 − 0.15 + 0.13 eV 2 , resulting in an upper limit of m ν < 0.45 eV at 90% confidence level. Stemming from 36 million electrons collected in 259 measurement days, a substantial reduction of the background level, and improved systematic uncertainties, this result tightens KATRIN’s previous bound by a factor of almost two.
- Open Access
- 1 April 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (04) , P04013
Commissioning of the 2.6 m tall two-phase xenon time projection chamber of Xenoscope
Xenoscope is a demonstrator for a next-generation xenon-based observatory for astroparticle physics, as proposed by the XLZD (XENON-LUX-ZEPLIN-DARWIN) collaboration. It houses a 2.6 m tall, two-phase xenon time projection chamber (TPC), in a cryostat filled with ∼360 kg of liquid xenon. The main goals of the facility are to demonstrate electron drift in liquid xenon over this distance, to measure the electron cloud transversal and longitudinal diffusion, as well as the optical properties of the medium. In this work, we describe in detail the construction and commissioning of the TPC and report on the observation of light and charge signals with cosmic muons.
- 1 April 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (04) , P04013
Open AccessCommissioning of the 2.6 m tall two-phase xenon time projection chamber of Xenoscope
Xenoscope is a demonstrator for a next-generation xenon-based observatory for astroparticle physics, as proposed by the XLZD (XENON-LUX-ZEPLIN-DARWIN) collaboration. It houses a 2.6 m tall, two-phase xenon time projection chamber (TPC), in a cryostat filled with ∼360 kg of liquid xenon. The main goals of the facility are to demonstrate electron drift in liquid xenon over this distance, to measure the electron cloud transversal and longitudinal diffusion, as well as the optical properties of the medium. In this work, we describe in detail the construction and commissioning of the TPC and report on the observation of light and charge signals with cosmic muons.
- Open Access
- 10 August 2023
- Published by Springer Nature in The European Physical Journal C
- Vol. 83 (8) , 1-15
Electron transport measurements in liquid xenon with Xenoscope, a large-scale DARWIN demonstrator
The DARWIN observatory is a proposed next-generation experiment with 40 tonnes of liquid xenon as an active target in a time projection chamber. To study challenges related to the construction and operation of a multi-tonne scale detector, we have designed and constructed a vertical, full-scale demonstrator for the DARWIN experiment at the University of Zurich. Here, we present the first results from a several-months run with $$343\,\hbox {kg}$$ of xenon and electron drift lifetime and transport measurements with a $$53\,\hbox {cm}$$ tall purity monitor immersed in the cryogenic liquid. After $$88\,\hbox {days}$$ of continuous purification, the electron lifetime reached a value of $$(664\,\pm \,23)\,\upmu \hbox {s}$$ . We measured the drift velocity of electrons for electric fields in the range (25–75) V/cm, and found values consistent with previous measurements. We also calculated the longitudinal diffusion constant of the electron cloud in the same field range, and compared with previous data, as well as with predictions from an empirical model.- 10 August 2023
- Published by Springer Nature in The European Physical Journal C
- Vol. 83 (8) , 1-15
Open AccessElectron transport measurements in liquid xenon with Xenoscope, a large-scale DARWIN demonstrator
The DARWIN observatory is a proposed next-generation experiment with 40 tonnes of liquid xenon as an active target in a time projection chamber. To study challenges related to the construction and operation of a multi-tonne scale detector, we have designed and constructed a vertical, full-scale demonstrator for the DARWIN experiment at the University of Zurich. Here, we present the first results from a several-months run with $$343\,\hbox {kg}$$ of xenon and electron drift lifetime and transport measurements with a $$53\,\hbox {cm}$$ tall purity monitor immersed in the cryogenic liquid. After $$88\,\hbox {days}$$ of continuous purification, the electron lifetime reached a value of $$(664\,\pm \,23)\,\upmu \hbox {s}$$ . We measured the drift velocity of electrons for electric fields in the range (25–75) V/cm, and found values consistent with previous measurements. We also calculated the longitudinal diffusion constant of the electron cloud in the same field range, and compared with previous data, as well as with predictions from an empirical model. - Open Access
- 1 August 2021
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 16 (08) , P08052
Design and construction of Xenoscope — a full-scale vertical demonstrator for the DARWIN observatory
The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and other rare interactions. It will operate a 50 t liquid xenon detector, with 40 t in the time projection chamber (TPC). To inform the final detector design and technical choices, a series of technological questions must first be addressed. Here we describe a full-scale demonstrator in the vertical dimension, Xenoscope, with the main goal of achieving electron drift over a 2.6 m distance, which is the scale of the DARWIN TPC. We have designed and constructed the facility infrastructure, including the cryostat, cryogenic and purification systems, the xenon storage and recuperation system, as well as the slow control system. We have also designed a xenon purity monitor and the TPC, with the fabrication of the former nearly complete. In a first commissioning run of the facility without an inner detector, we demonstrated the nominal operational reach of Xenoscope and benchmarked the components of the cryogenic and slow control systems, demonstrating reliable and continuous operation of all subsystems over 40 days. The infrastructure is thus ready for the integration of the purity monitor, followed by the TPC. Further applications of the facility include R&D on the high voltage feedthrough for DARWIN, measurements of electron cloud diffusion, as well as measurements of optical properties of liquid xenon. In the future, Xenoscope will be available as a test platform for the DARWIN collaboration to characterise new detector technologies.
- 1 August 2021
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 16 (08) , P08052
Open AccessDesign and construction of Xenoscope — a full-scale vertical demonstrator for the DARWIN observatory
The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and other rare interactions. It will operate a 50 t liquid xenon detector, with 40 t in the time projection chamber (TPC). To inform the final detector design and technical choices, a series of technological questions must first be addressed. Here we describe a full-scale demonstrator in the vertical dimension, Xenoscope, with the main goal of achieving electron drift over a 2.6 m distance, which is the scale of the DARWIN TPC. We have designed and constructed the facility infrastructure, including the cryostat, cryogenic and purification systems, the xenon storage and recuperation system, as well as the slow control system. We have also designed a xenon purity monitor and the TPC, with the fabrication of the former nearly complete. In a first commissioning run of the facility without an inner detector, we demonstrated the nominal operational reach of Xenoscope and benchmarked the components of the cryogenic and slow control systems, demonstrating reliable and continuous operation of all subsystems over 40 days. The infrastructure is thus ready for the integration of the purity monitor, followed by the TPC. Further applications of the facility include R&D on the high voltage feedthrough for DARWIN, measurements of electron cloud diffusion, as well as measurements of optical properties of liquid xenon. In the future, Xenoscope will be available as a test platform for the DARWIN collaboration to characterise new detector technologies.