MRMalte Rolf-Pissarczyk

Malte Rolf-Pissarczyk

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Malte Rolf-Pissarczyk has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Feasibility study of fluid-structure-growth modeling in the context of endogenous tissue restoration

    by Lauranne Maes, Amber Hendrickx, Hadi Shirazi, Deniz Ozturk, Maria Bastron, Tahir Turgut, Vincent Bouwman, Nils Götzen, Thibault Vervenne, Malte Rolf, et al.

    In situ tissue engineering exploits natural inflammatory responses to turn a synthetic vascular graft into a regenerated, functioning, and living vessel through endogenous tissue restoration. Despite promising preclinical results, challenges remain, especially in high-pressure regimes. To better understand the underlying biological processes and predict long-term outcomes of graft implantation, we propose an in silico approach. We account for the solid mechanics of conduit grafts in high and low pressure regimes, the wall shear stresses, and long-term growth and remodeling through two reduced-order fluid-structure-growth models. The first employs an artificial neural network surrogate model to compute the time-averaged wall shear stress at every growth step, whereas the second evaluates a fully-coupled fluid-structure interaction model every 60 time steps. We thoroughly verify both models and confirm acceptable model-form errors, then calibrate them against data from animal experiments. A validation study comparing in silico predictions with unseen animal data of carotid and pulmonary conduit grafts confirms that the model remains reliable up to at least one month of prediction time, hence in the future enabling in silico optimization of short-term endogenous tissue restoration in tissue engineering vascular grafts.

  • Open Access

    Reanimating the past: From historical collections of the placenta and uterus to modern imaging, machine learning, and multiscale modeling

    by Malte Rolf, Sahan Jayatissa, Jonathan Reshef, Stefan Posch, Ellen Kuhl, Joanna L. James, Alys R. Clark, Hanna H. Allerkamp


  • Computational modeling of endogenous tissue restoration in biodegradable implants: Bridging scaffold degradation and neo-tissue adaptation

    by Hadi Shirazi, Lauranne Maes, Thibault Vervenne, Amber Hendrickx, Felipe Sempértegui, Malte Rolf, Nils Götzen, Martijn Cox, Gerhard A. Holzapfel, Stéphane Avril, et al.


  • Open Access

    A Parameterized Cross‐Sectional Model for Simulating Balloon Angioplasty in Atherosclerotic Arteries

    by Sanne M. B. Kwakman, Michele Terzano, Malte Rolf, Gerhard A. Holzapfel

    Atherosclerotic arteries exhibit geometric alterations due to plaque deposition, which often leads to luminal narrowing. Balloon angioplasty is a common and suggested treatment to restore blood flow. However, depending on balloon oversizing, rupture at the plaque shoulder or the fibrous cap may occur. The rupture risk is influenced by factors such as the geometry of the fibrous cap, the lipid pool size, and calcifications. Despite advances in clinical imaging, predicting plaque rupture remains challenging because of lesion variability. This study addresses this gap by identifying key geometrical factors that influence stress distribution during balloon angioplasty, thus improving biomechanical insights and risk assessment. In this work, we develop a parameterized cross‐sectional model of the atherosclerotic artery to investigate the influence of these components on stress distribution during balloon angioplasty. This model can be adapted to different stages and geometries of atherosclerosis. The parametric model enables the evaluation of the influence of uncertain input parameters, especially geometrical parameters, on the outcome of a finite element analysis. Experimental data from a layer‐specific mechanical test on an iliac artery and pressure–diameter curves from balloon inflation tests are used to calibrate the respective constitutive models. Balloon angioplasty is then simulated by inflating a balloon in the narrowed artery without explicitly considering balloon unfolding. We perform simulations for a local sensitivity analysis by varying the six most influential geometrical parameters and leaving the remaining parameters and the material parameters unchanged. The results show that the amount of the lipid pool has the largest influence on the maximum principal stress in the arterial tissue. Furthermore, the thickness of the fibrous cap plays a critical role in determining the specific location where this maximum occurs. These findings offer valuable insights into potential initiation sites of damage in atherosclerotic arteries.


  • Open Access

    Assessment of Aortic Dissection Remodeling With Patient-Specific Fluid–Structure Interaction Models

    by Kathrin Bäumler, Malte Rolf-Pissarczyk, Richard Schussnig, Thomas-Peter Fries, Gabriel Mistelbauer, Martin R. Pfaller, Alison L. Marsden, Dominik Fleischmann, Gerhard A. Holzapfel

    Aortic dissection leads to late complications due tochronic degeneration and dilatation of the false lumen. This study examines the interaction between hemodynamics and long-term remodeling of a patient's aortic dissection, tracked from pre-dissection to the chronic phase using CT angiography. Fluid–structure interaction models with tissue prestress, external support, and anisotropic properties were used to analyze hemodynamic markers. Each aortic wall layer had distinct thicknesses and material properties. The boundary conditions were guided by in vitro 4D-flow MRI and the patient's blood pressure. Aortic dilatation was most significant distal to the left subclavian artery, reaching 6 cm in the chronic phase. Simulations quantified the flow jet velocity through the entry tear, which peaked at 185 cm/s in the subacute phase and decreased to 123 to 133 cm/s in the chronic phase, corresponding to an increased entry tear size. Flow jet impingement on the false lumen resulted in a localized pressure increase of 11 and 2 mmHg in the subacute and chronic phases, with wall shear stress reaching 4 Pa. These hemodynamic changes appear to be the main drivers of aortic growth and morphological changes. Despite moderate overall flap movement, in-plane displacement increased from 0.6 to 1.8 mm as disease progressed, which was associated with an overall increase in aortic diameter. Simulations with a significant reduction in flap stiffness during the subacute phase resulted in increased flap motion up to 9.5 mm. Although these results are based on a single patient, they suggest a strong relationship between hemodynamics and aortic growth.


  • Open Access

    On the role of tissue mechanics in fluid–structure interaction simulations of patient‐specific aortic dissection

    by Richard Schussnig, Malte Rolf‐Pissarczyk, Kathrin Bäumler, Thomas‐Peter Fries, Gerhard A. Holzapfel, Martin Kronbichler

    Modeling an aortic dissection represents a particular challenge from a numerical perspective, especially when it comes to the interaction between solid (aortic wall) and liquid (blood flow). The complexity of patient‐specific simulations requires a variety of parameters, modeling assumptions and simplifications that currently hinder their routine use in clinical settings. We present a numerical framework that captures, among other things, the layer‐specific anisotropic properties of the aortic wall, the non‐Newtonian behavior of blood, patient‐specific geometry, and patient‐specific flow conditions. We compare hemodynamic indicators and stress measurements in simulations with increasingly complex material models for the vessel tissue ranging from rigid walls to anisotropic hyperelastic materials. We find that for the present geometry and boundary conditions, rigid wall simulations produce different results than fluid–structure interaction simulations. Considering anisotropic fiber contributions in the tissue model, stress measurements in the aortic wall differ, but shear stress‐based biomarkers are less affected. In summary, the increasing complexity of the tissue model enables capturing more details. However, an extensive parameter set is also required. Since the simulation results depend on these modeling choices, variations can lead to different recommendations in clinical applications.


  • Modelling the anisotropic inelastic response of polymeric scaffolds for in situ tissue engineering applications

    by Michele Terzano, Maximilian P. Wollner, Manuel P. Kainz, Malte Rolf-Pissarczyk, Nils Götzen, Gerhard A. Holzapfel

    In situ tissue engineering offers an innovative solution for replacement valves and grafts in cardiovascular medicine. In this approach, a scaffold, which can be obtained by polymer electrospinning, is implanted into the human body and then infiltrated by cells, eventually replacing the scaffold with native tissue. In silico simulations of the whole process in patient-specific models, including implantation, growth and degradation, are very attractive to study the factors that might influence the end result. In our research, we focused on the mechanical behaviour of the polymeric scaffold and its short-term response. Following a recently proposed constitutive model for the anisotropic inelastic behaviour of fibrous polymeric materials, we present here its numerical implementation in a finite element framework. The numerical model is developed as user material for commercial finite element software. The verification of the implementation is performed for elementary deformations. Furthermore, a parallel-plate test is proposed as a large-scale representative example, and the model is validated by comparison with experiments.


  • Open Access

    A general model for anisotropic pseudo-elasticity and viscoelasticity at finite strains

    by Maximilian P. Wollner, Michele Terzano, Malte Rolf-Pissarczyk, Gerhard A. Holzapfel


  • Open Access

    Stochastic Modeling of Inhomogeneities in the Aortic Wall and Uncertainty Quantification using a Bayesian Encoder-Decoder Surrogate

    by Sascha Ranftl, Malte Rolf-Pissarczyk, Gloria Wolkerstorfer, Antonio Pepe, Jan Egger, Wolfgang von der Linden, Gerhard A. Holzapfel

    Inhomogeneities in the aortic wall can lead to localized stress accumulations, possibly initiating dissection. In many cases, a dissection results from pathological changes such as fragmentation or loss of elastic fibers. But it has been shown that even the healthy aortic wall has an inherent heterogeneous microstructure. Some parts of the aorta are particularly susceptible to the development of inhomogeneities due to pathological changes, however, the distribution in the aortic wall and the spatial extent, such as size, shape, and type, are difficult to predict. Motivated by this observation, we describe the heterogeneous distribution of elastic fiber degradation in the dissected aortic wall using a stochastic constitutive model. For this purpose, random field realizations, which model the stochastic distribution of degraded elastic fibers, are generated over a non-equidistant grid. The random field then serves as input for a uni-axial extension test of the pathological aortic wall, solved with the finite-element (FE) method. To include the microstructure of the dissected aortic wall, a constitutive model developed in a previous study is applied, which also includes an approach to model the degradation of inter-lamellar elastic fibers. Then to assess the uncertainty in the output stress distribution due to this stochastic constitutive model, a convolutional neural network, specifically a Bayesian encoder-decoder, was used as a surrogate model that maps the random input fields to the output stress distribution obtained from the FE analysis. The results show that the neural network is able to predict the stress distribution of the FE analysis while significantly reducing the computational time. In addition, it provides the probability for exceeding critical stresses within the aortic wall, which could allow for the prediction of delamination or fatal rupture.