Werner Anderl
Research Subjects
Werner Anderl has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Leo Pauzenberger
HealthPi, Vienna, Austria
2 shared publications - Philipp R. Heuberer
Austrian Research Group for Regenerative and Orthopedic Medicine (AURROM), 1050 Vienna, Austria
2 shared publications - Augustus D. Mazzocca
Division of Sports Medicine, Department of Orthopaedic Surgery, Harvard School of Medicine, Massachusetts General Brigham, Boston, MA 02115, USA
1 shared publication Bernhard Kriegleder
St. Vincent Shoulder & Sports Clinic, Vienna, Austria
1 shared publication- Coen A. Wijdicks
Department of Orthopedic Research, Arthrex, Inc, Naples, Florida, USA
1 shared publication Daniel Ritter
Arthrex Department of Orthopedic Research, Munich, Germany
1 shared publication
Latest Publications
- 1 November 2021
- Published by Elsevier in Seminars in Arthroplasty: JSES
- Vol. 31 (4) , 677-687
Postpreparation peri-implant humeral bone density and fixation strength vary based on design in stemless reverse shoulder arthroplasty
- 1 November 2021
- Published by Elsevier in Seminars in Arthroplasty: JSES
- Vol. 31 (4) , 677-687
Postpreparation peri-implant humeral bone density and fixation strength vary based on design in stemless reverse shoulder arthroplasty
- 1 January 2020
- Published by Wolters Kluwer Health in JBJS Essential Surgical Techniques
- Vol. 10 (1) , e0109
Arthroscopic, Implant-Free Bone-Grafting for Shoulder Instability with Glenoid Bone Loss
Background: Anterior shoulder instability is commonly associated with injuries to the labrocapsular structures of the glenohumeral joint and with osseous glenoid defects of varying degree. If the bone defect exceeds a clinically relevant threshold, mere soft-tissue repairs result in high rates of recurrent instability and the glenoid needs to be reconstructed with osseous augmentation. The most popular techniques for glenoid reconstruction include variations of coracoid transfer or bone-block procedures; however, these procedures are not free from risks and complications, which are often related to the method of fixation 1 . An alternative to the widely used coracoid transfer variations or bone-block procedures is anatomic implant-free glenoid reconstruction with a J-shaped iliac-crest bone graft. After press-fit fixation, the graft undergoes a physiological remodeling process resulting in the restoration of native scapular neck morphology. Although not as widely known, the open J-bone-graft procedure has been successfully used for the treatment of glenoid bone loss for nearly 3 decades 2–4 . The arthroscopic J-bone-graft technique represents an innovative advancement of the open procedure. Early to midterm follow-up of the arthroscopic J-bone-graft technique has revealed excellent clinical results 1 . Description: The major steps of the procedure, which are demonstrated in the present video article, include (1) detachment of the labrocapsular ligamentous complex and preparation of the anterior aspect of the glenoid, (2) establishment of a deep anterior-inferior portal and splitting of the subscapularis tendon, (3) introduction of the “waterslide,” (4) osteotomy at the scapular neck 30° relative to the glenoid surface and trial impaction, (5 and 6) harvesting and preparation of a J-shaped bicortical iliac-crest bone graft, (7) press-fit impaction of the bone graft in the prepared osteotomy over the “waterslide“, and (8) capsuloligamentous repair over the graft. Alternatives: Coracoid transfer (Latarjet-Bristow), iliac-crest bone-grafting, and distal tibial allograft. Rationale: Although widely in use, nonanatomic coracoid transfer procedures or bone-block techniques relying on hardware fixation are associated with specific complications, including nonunion, osteolysis, coracoid fractures, hardware complications, and difficult revision 1 . Many of these disadvantages can be avoided by the use of anatomic implant-free glenoid reconstruction with a J-shaped iliac-crest bone graft. After press-fit fixation, the graft undergoes a physiological remodeling process that follows the law of bone adaptation to mechanical stresses described by Wolff, which ultimately results in the restoration of a nearly native anterior scapular neck morphology 4 . The open version of this technique has been successfully used for over 3 decades. The arthroscopic, minimally invasive variation of the J-bone-graft technique presented in this video article represents a further advancement of the anatomic nature of the procedure. Expected Outcomes: The arthroscopic implant-free J-bone-graft technique is an alternative to other procedures widely used for the treatment of anterior glenoid bone defects. The main advantage of this technique is the avoidance of severe complications that arise from the nonanatomic reconstruction and fixation methods found with other procedures 1 . Early to midterm follow-up of the arthroscopic J-bone-graft technique has revealed excellent clinical results, and the traditional open technique has been in use successfully for over 3 decades 2–5 . Previous patients have been able to return to a variety of occupational and athletic activities including overhead, throwing, and contact sports. Return to daily living and to moderate athletic activities is usually possible within 3 months. Return to competition is allowed after 6 months 2–5 . Important Tips:
- 1 January 2020
- Published by Wolters Kluwer Health in JBJS Essential Surgical Techniques
- Vol. 10 (1) , e0109
Arthroscopic, Implant-Free Bone-Grafting for Shoulder Instability with Glenoid Bone Loss
Background: Anterior shoulder instability is commonly associated with injuries to the labrocapsular structures of the glenohumeral joint and with osseous glenoid defects of varying degree. If the bone defect exceeds a clinically relevant threshold, mere soft-tissue repairs result in high rates of recurrent instability and the glenoid needs to be reconstructed with osseous augmentation. The most popular techniques for glenoid reconstruction include variations of coracoid transfer or bone-block procedures; however, these procedures are not free from risks and complications, which are often related to the method of fixation 1 . An alternative to the widely used coracoid transfer variations or bone-block procedures is anatomic implant-free glenoid reconstruction with a J-shaped iliac-crest bone graft. After press-fit fixation, the graft undergoes a physiological remodeling process resulting in the restoration of native scapular neck morphology. Although not as widely known, the open J-bone-graft procedure has been successfully used for the treatment of glenoid bone loss for nearly 3 decades 2–4 . The arthroscopic J-bone-graft technique represents an innovative advancement of the open procedure. Early to midterm follow-up of the arthroscopic J-bone-graft technique has revealed excellent clinical results 1 . Description: The major steps of the procedure, which are demonstrated in the present video article, include (1) detachment of the labrocapsular ligamentous complex and preparation of the anterior aspect of the glenoid, (2) establishment of a deep anterior-inferior portal and splitting of the subscapularis tendon, (3) introduction of the “waterslide,” (4) osteotomy at the scapular neck 30° relative to the glenoid surface and trial impaction, (5 and 6) harvesting and preparation of a J-shaped bicortical iliac-crest bone graft, (7) press-fit impaction of the bone graft in the prepared osteotomy over the “waterslide“, and (8) capsuloligamentous repair over the graft. Alternatives: Coracoid transfer (Latarjet-Bristow), iliac-crest bone-grafting, and distal tibial allograft. Rationale: Although widely in use, nonanatomic coracoid transfer procedures or bone-block techniques relying on hardware fixation are associated with specific complications, including nonunion, osteolysis, coracoid fractures, hardware complications, and difficult revision 1 . Many of these disadvantages can be avoided by the use of anatomic implant-free glenoid reconstruction with a J-shaped iliac-crest bone graft. After press-fit fixation, the graft undergoes a physiological remodeling process that follows the law of bone adaptation to mechanical stresses described by Wolff, which ultimately results in the restoration of a nearly native anterior scapular neck morphology 4 . The open version of this technique has been successfully used for over 3 decades. The arthroscopic, minimally invasive variation of the J-bone-graft technique presented in this video article represents a further advancement of the anatomic nature of the procedure. Expected Outcomes: The arthroscopic implant-free J-bone-graft technique is an alternative to other procedures widely used for the treatment of anterior glenoid bone defects. The main advantage of this technique is the avoidance of severe complications that arise from the nonanatomic reconstruction and fixation methods found with other procedures 1 . Early to midterm follow-up of the arthroscopic J-bone-graft technique has revealed excellent clinical results, and the traditional open technique has been in use successfully for over 3 decades 2–5 . Previous patients have been able to return to a variety of occupational and athletic activities including overhead, throwing, and contact sports. Return to daily living and to moderate athletic activities is usually possible within 3 months. Return to competition is allowed after 6 months 2–5 . Important Tips:
- 4 October 2018
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 46 (13) , 3165-3173
Double-Layer Rotator Cuff Repair: Anatomic Reconstruction of the Superior Capsule and Rotator Cuff Improves Biomechanical Properties in Repairs of Delaminated Rotator Cuff Tears
Background: Delamination in rotator cuff tears has been identified as a prognostic factor for negative outcome after repair, with a reported prevalence between 38% and 88%. Purpose: To compare biomechanical properties of 3 repair techniques for delaminated rotator cuff tears. Study Design: Controlled laboratory study. Methods: Eighteen fresh-frozen cadaveric shoulders were used to evaluate rotator cuff footprint reconstruction, contact area and pressure, displacement under cyclical loading, and load to failure of 3 double-row repair configurations: double-row suture repair with medial row knots (medially knotted bridge, mkB); knotless double-row repair using suture tapes (knotless bridge, klB); and knotless double-row, double-layer-specific repair (double-layer, DL). Dynamic pressure sensors were used to assess contact patterns at the footprint region in 0°, 30°, and 60° of glenohumeral abduction and 5 rotational positions (0°, 30° of internal rotation, 30° of external rotation, 60° of internal rotation, 60° of external rotation). Optical markers were used to document whole tendon and individual layer displacement after rotator cuff repair under cyclical loading for 200 cycles (10 N to 100 N at 1 Hz). Specimens were then loaded monotonically to failure at a rate of 33 mm/min. Results: Mean contact area and footprint restoration were highest in the DL group at 60° of glenohumeral abduction for all rotational positions (mkB mean ± SD, 195.4 ± 54.3 mm 2 , 66.7% ± 19.7%; klB, 250.6 ± 34.9 mm 2 , 76.2% ± 10.3%; DL, 318.4 ± 36.6 mm 2 , 109.1% ± 24.0%; P < .001). The double-layer-specific repair showed the least displacement under cyclical loading (mkB mean ± SD, 0.53 ± 0.18 mm; klB, 0.79 ± 0.37 mm; DL, 0.31 ± 0.24 mm; P = .029), most closely resembling the native tendon. Peak loads at failure were comparable between repair groups (mkB mean ± SD, 366.92 ± 70.59 N; klB, 280.05 ± 77.66 N; DL, 398.35 ± 109.04 N; P = .083). Conclusion: Anatomic restoration of the superior capsular and tendon insertion in delaminated rotator cuff tears with a double-layer-specific repair configuration demonstrated superior footprint restoration with increasing abduction, while providing construct displacement comparable to the native tendon under cyclical loading. Peak load at failure was comparable between repair constructs. Clinical Relevance: The prevalence and clinical importance of delaminated rotator cuff tears have long been underestimated. Anatomically correct individual reconstruction of the superior capsule and rotator cuff could restore near-native biomechanics and potentially reduce the risk of rotator cuff repair failure.
- 4 October 2018
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 46 (13) , 3165-3173
Double-Layer Rotator Cuff Repair: Anatomic Reconstruction of the Superior Capsule and Rotator Cuff Improves Biomechanical Properties in Repairs of Delaminated Rotator Cuff Tears
Background: Delamination in rotator cuff tears has been identified as a prognostic factor for negative outcome after repair, with a reported prevalence between 38% and 88%. Purpose: To compare biomechanical properties of 3 repair techniques for delaminated rotator cuff tears. Study Design: Controlled laboratory study. Methods: Eighteen fresh-frozen cadaveric shoulders were used to evaluate rotator cuff footprint reconstruction, contact area and pressure, displacement under cyclical loading, and load to failure of 3 double-row repair configurations: double-row suture repair with medial row knots (medially knotted bridge, mkB); knotless double-row repair using suture tapes (knotless bridge, klB); and knotless double-row, double-layer-specific repair (double-layer, DL). Dynamic pressure sensors were used to assess contact patterns at the footprint region in 0°, 30°, and 60° of glenohumeral abduction and 5 rotational positions (0°, 30° of internal rotation, 30° of external rotation, 60° of internal rotation, 60° of external rotation). Optical markers were used to document whole tendon and individual layer displacement after rotator cuff repair under cyclical loading for 200 cycles (10 N to 100 N at 1 Hz). Specimens were then loaded monotonically to failure at a rate of 33 mm/min. Results: Mean contact area and footprint restoration were highest in the DL group at 60° of glenohumeral abduction for all rotational positions (mkB mean ± SD, 195.4 ± 54.3 mm 2 , 66.7% ± 19.7%; klB, 250.6 ± 34.9 mm 2 , 76.2% ± 10.3%; DL, 318.4 ± 36.6 mm 2 , 109.1% ± 24.0%; P < .001). The double-layer-specific repair showed the least displacement under cyclical loading (mkB mean ± SD, 0.53 ± 0.18 mm; klB, 0.79 ± 0.37 mm; DL, 0.31 ± 0.24 mm; P = .029), most closely resembling the native tendon. Peak loads at failure were comparable between repair groups (mkB mean ± SD, 366.92 ± 70.59 N; klB, 280.05 ± 77.66 N; DL, 398.35 ± 109.04 N; P = .083). Conclusion: Anatomic restoration of the superior capsular and tendon insertion in delaminated rotator cuff tears with a double-layer-specific repair configuration demonstrated superior footprint restoration with increasing abduction, while providing construct displacement comparable to the native tendon under cyclical loading. Peak load at failure was comparable between repair constructs. Clinical Relevance: The prevalence and clinical importance of delaminated rotator cuff tears have long been underestimated. Anatomically correct individual reconstruction of the superior capsule and rotator cuff could restore near-native biomechanics and potentially reduce the risk of rotator cuff repair failure.