John Fergason
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
John Fergason has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Jason Mitchell Wilken
Department of Physical Therapy and Rehabilitation Science, University of Iowa, Iowa City, IA, USA
2 shared publications - Andrea J. Ikeda
Regenstein Center for Bionic Medicine, Shirley Ryan AbilityLab, Chicago, Illinois, United States of America
1 shared publication - Benjamin Kyle Potter
Department of Surgery, Uniformed Services University of Health Sciences, Bethesda, MD, USA
1 shared publication - Daniel J. Stinner
Division of Orthopaedic Trauma, Vanderbilt University Medical Center , Nashville, TN 37232
1 shared publication - Daniel O. Scharfstein
University of Utah , School of Medicine, Department of Population Health Sciences, Division of Biostatistics; 295 Chipeta Way, Salt Lake City, UT 84108
1 shared publication - Ellen J. MacKenzie
Johns Hopkins Bloomberg School of Public Health, Baltimore, MD
1 shared publication
Latest Publications
- Open Access
- 23 February 2019
- Published by Oxford University Press (OUP) in Military Medicine
- Vol. 184 (11-12) , 601-605
Clinical Outcomes with the Intrepid Dynamic Exoskeletal Orthosis: A Retrospective Analysis
Severe lower limb injuries have a negative impact on many aspects of an individual’s life. One rehabilitative option for patients who have undergone limb salvage is the Intrepid Dynamic Exoskeletal Orthosis (IDEO). The IDEO is a custom-made dynamic response device which is used to restore function for patients with a wide variety of injuries. Clinical outcomes were routinely collected on patients fit with IDEOs at the Center for the Intrepid, Brooke Army Medical Center. The purpose of this retrospective study was to analyze the clinical outcomes collection process and the patient outcomes collected as part of routine clinical care. The Brooke Army Medical Center IRB approved this study and granted waivers of informed consent and HIPAA authorization. Electronic medical records were reviewed over an 18-month period from July 2014 to January 2016. Records were examined to obtain the date of IDEO delivery, date of outcomes form completion, responses on the forms, and to verify diagnosis or injury. Data gathered included wear time, IDEO comfort, pain with and without the IDEO, Lower Extremity Functional Scale scores with and without the IDEO, and global rating of change questions for everyday activities and high impact activities. Wilcoxon signed-ranked tests were used to compare pain and function with vs. without the IDEO. During the 18-month period, new IDEOs were delivered to 156 unique patients. Outcomes forms were collected as part of routine clinical care from 90 of these 156 patients (58%). An additional nine forms were collected from patients who received their IDEOs prior to July 2014. In all, 99 outcomes forms were collected. Mean follow-up time from IDEO delivery to outcomes form completion was 35 ± 31 days for the original 90 patients. The most common patient diagnoses were fracture, nerve injury, arthritis, and fusion. Responses on the forms indicated that patients were generally comfortable wearing their IDEOs (8.3 ± 1.3 on a 0–10 scale) and wore them most of the day (10.7 ± 3.4 hours per day). Improvement in pain (from 5.2 ± 2.9 to 1.7 ± 1.6 points on a 0–10 scale) and Lower Extremity Functional Scale scores (from 29.7 ± 16.6 to 59.5 ± 13.6 points) with the IDEO were both more than the minimal clinically important difference and were statistically significant (p < 0.001). This descriptive retrospective study demonstrated that it was feasible to collect clinical outcomes data which were relevant for characterizing the effects of IDEO use and enabled quantification of improvements in self-reported function and walking pain with the IDEO. Due to the retrospective nature of this study, limitations include missing data and the lack of any performance measures to complement the self-reported data. Clinical outcomes collection continues as a routine part of clinical care and there remains an ongoing aim to collect information on all patients to obtain an accurate assessment of devices and services and ultimately better serve our patients.
- 23 February 2019
- Published by Oxford University Press (OUP) in Military Medicine
- Vol. 184 (11-12) , 601-605
Open AccessClinical Outcomes with the Intrepid Dynamic Exoskeletal Orthosis: A Retrospective Analysis
Severe lower limb injuries have a negative impact on many aspects of an individual’s life. One rehabilitative option for patients who have undergone limb salvage is the Intrepid Dynamic Exoskeletal Orthosis (IDEO). The IDEO is a custom-made dynamic response device which is used to restore function for patients with a wide variety of injuries. Clinical outcomes were routinely collected on patients fit with IDEOs at the Center for the Intrepid, Brooke Army Medical Center. The purpose of this retrospective study was to analyze the clinical outcomes collection process and the patient outcomes collected as part of routine clinical care. The Brooke Army Medical Center IRB approved this study and granted waivers of informed consent and HIPAA authorization. Electronic medical records were reviewed over an 18-month period from July 2014 to January 2016. Records were examined to obtain the date of IDEO delivery, date of outcomes form completion, responses on the forms, and to verify diagnosis or injury. Data gathered included wear time, IDEO comfort, pain with and without the IDEO, Lower Extremity Functional Scale scores with and without the IDEO, and global rating of change questions for everyday activities and high impact activities. Wilcoxon signed-ranked tests were used to compare pain and function with vs. without the IDEO. During the 18-month period, new IDEOs were delivered to 156 unique patients. Outcomes forms were collected as part of routine clinical care from 90 of these 156 patients (58%). An additional nine forms were collected from patients who received their IDEOs prior to July 2014. In all, 99 outcomes forms were collected. Mean follow-up time from IDEO delivery to outcomes form completion was 35 ± 31 days for the original 90 patients. The most common patient diagnoses were fracture, nerve injury, arthritis, and fusion. Responses on the forms indicated that patients were generally comfortable wearing their IDEOs (8.3 ± 1.3 on a 0–10 scale) and wore them most of the day (10.7 ± 3.4 hours per day). Improvement in pain (from 5.2 ± 2.9 to 1.7 ± 1.6 points on a 0–10 scale) and Lower Extremity Functional Scale scores (from 29.7 ± 16.6 to 59.5 ± 13.6 points) with the IDEO were both more than the minimal clinically important difference and were statistically significant (p < 0.001). This descriptive retrospective study demonstrated that it was feasible to collect clinical outcomes data which were relevant for characterizing the effects of IDEO use and enabled quantification of improvements in self-reported function and walking pain with the IDEO. Due to the retrospective nature of this study, limitations include missing data and the lack of any performance measures to complement the self-reported data. Clinical outcomes collection continues as a routine part of clinical care and there remains an ongoing aim to collect information on all patients to obtain an accurate assessment of devices and services and ultimately better serve our patients.
- 17 October 2018
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 100 (20) , 1781-1789
Multisite Evaluation of a Custom Energy-Storing Carbon Fiber Orthosis for Patients with Residual Disability After Lower-Limb Trauma
Background: The Intrepid Dynamic Exoskeletal Orthosis (IDEO) is a custom energy-storing carbon fiber ankle-foot orthosis developed for lower-extremity trauma patients. Studies conducted at the military treatment facility where the IDEO was developed demonstrated benefits of the IDEO when used with the Return to Run Physical Therapy (RTR PT) program. The current study was designed to determine if results could be replicated at other military treatment facilities and to examine whether early performance gains in patient-reported functional outcomes remained at 12 months. Methods: Study participants included service members who had functional deficits that interfered with daily activities at least 1 year after a traumatic unilateral lower-extremity injury at or below the knee. Participants were evaluated before receiving the IDEO, immediately following completion of RTR PT, and at 6 and 12 months. Agility, strength/power, and speed were assessed using well-established performance tests. Self-reported function was measured using the Short Musculoskeletal Function Assessment (SMFA). The Orthotics and Prosthetics Users’ Survey was administered to assess satisfaction with the IDEO. Of 87 participants with complete baseline data, 6 did not complete any physical therapy and were excluded from the analysis. Follow-up rates immediately following completion of the RTR PT and at 6 and 12 months were 88%, 75%, and 79%, respectively. Results: Compared with baseline, improvement at completion of RTR PT was observed in all but 1 performance test. SMFA scores for all domains except hand and arm function were lower (improved function) at 6 and 12 months. Satisfaction with the IDEO was high following completion of RTR PT, with some attenuation at the time of follow-up. Conclusions: This study adds to the evidence supporting the efficacy of the IDEO coupled with RTR PT. However, despite improvement in both performance and self-reported functioning, deficits persist compared with population norms. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 17 October 2018
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 100 (20) , 1781-1789
Multisite Evaluation of a Custom Energy-Storing Carbon Fiber Orthosis for Patients with Residual Disability After Lower-Limb Trauma
Background: The Intrepid Dynamic Exoskeletal Orthosis (IDEO) is a custom energy-storing carbon fiber ankle-foot orthosis developed for lower-extremity trauma patients. Studies conducted at the military treatment facility where the IDEO was developed demonstrated benefits of the IDEO when used with the Return to Run Physical Therapy (RTR PT) program. The current study was designed to determine if results could be replicated at other military treatment facilities and to examine whether early performance gains in patient-reported functional outcomes remained at 12 months. Methods: Study participants included service members who had functional deficits that interfered with daily activities at least 1 year after a traumatic unilateral lower-extremity injury at or below the knee. Participants were evaluated before receiving the IDEO, immediately following completion of RTR PT, and at 6 and 12 months. Agility, strength/power, and speed were assessed using well-established performance tests. Self-reported function was measured using the Short Musculoskeletal Function Assessment (SMFA). The Orthotics and Prosthetics Users’ Survey was administered to assess satisfaction with the IDEO. Of 87 participants with complete baseline data, 6 did not complete any physical therapy and were excluded from the analysis. Follow-up rates immediately following completion of the RTR PT and at 6 and 12 months were 88%, 75%, and 79%, respectively. Results: Compared with baseline, improvement at completion of RTR PT was observed in all but 1 performance test. SMFA scores for all domains except hand and arm function were lower (improved function) at 6 and 12 months. Satisfaction with the IDEO was high following completion of RTR PT, with some attenuation at the time of follow-up. Conclusions: This study adds to the evidence supporting the efficacy of the IDEO coupled with RTR PT. However, despite improvement in both performance and self-reported functioning, deficits persist compared with population norms. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.