Haocheng Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Haocheng Ma has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Hai-Feng Zhang
College of Electronic and Optical Engineering & College of Flexible Electronics (Future Technology), Nanjing University of Posts and Telecommunications (NJUPT) 1 , Nanjing 210023
1 shared publication - Jingwei Huang
College of Electronic and Optical Engineering & College of Flexible Electronics (Future Technology), Nanjing University of Posts and Telecommunications, Nanjing 210023, China
1 shared publication - Junyang Sui
College of Electronic and Optical Engineering & College of Flexible Electronics (Future Technology), Nanjing University of Posts and Telecommunications, Nanjing 210023, China
1 shared publication - Qi Chen
College of Electronic and Optical Engineering & College of Flexible Electronics (Future Technology), Nanjing University of Posts and Telecommunications, Nanjing 210023, China
1 shared publication - Si-Yuan Liao
Shenzhen Institute of Advanced Electronic Materials, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
1 shared publication
Latest Publications
- Open Access
A Liquid Crystal-Modulated Metastructure Sensor for Biosensing
In this paper, a liquid crystal-modulated metastructure sensor (MS) is proposed that can detect the refractive index (RI) of a liquid and change the detection range under different applied voltages. The regulation of the detection range is based on the different bias states of the liquid crystal at different voltages. By changing the sample in the cavity that is to be detected, the overall electromagnetic characteristics of the device in the resonant state are modified, thus changing the position of the absorption peaks so that different RI correspond to different absorption peaks, and finally realizing the sensing detection. The refractive index unit is denoted as RIU. The range of the refractive index detection is 1.414–2.828 and 2.121–3.464, and the corresponding absorption peak variation range is 0.8485–1.028 THz and 0.7295–0.8328 THz, with a sensitivity of 123.8 GHz/RIU and 75.6 GHz/RIU, respectively. In addition, an approach to optimizing resonant absorption peaks is explored, which can suppress unwanted absorption generated during the design process by analyzing the energy distribution and directing the current flow on the substrate. Four variables that have a more obvious impact on performance are listed, and the selection and change trend of the numerical values are focused on, fully considering the errors that may be caused by manufacturing and actual use. At the same time, the incident angle and polarization angle are also included in the considered range, and the device shows good stability at these angles. Finally, the influence of the number of resonant rings on the sensing performance is also discussed, and its conclusion has guiding value for optimizing the sensing demand. This new liquid crystal-modulated MS has the advantages of a small size and high sensitivity and is expected to be used for bio-detection, sensing, and so on. All results in this work were obtained with the aid of simulations based on the finite element method.
Open AccessA Liquid Crystal-Modulated Metastructure Sensor for Biosensing
In this paper, a liquid crystal-modulated metastructure sensor (MS) is proposed that can detect the refractive index (RI) of a liquid and change the detection range under different applied voltages. The regulation of the detection range is based on the different bias states of the liquid crystal at different voltages. By changing the sample in the cavity that is to be detected, the overall electromagnetic characteristics of the device in the resonant state are modified, thus changing the position of the absorption peaks so that different RI correspond to different absorption peaks, and finally realizing the sensing detection. The refractive index unit is denoted as RIU. The range of the refractive index detection is 1.414–2.828 and 2.121–3.464, and the corresponding absorption peak variation range is 0.8485–1.028 THz and 0.7295–0.8328 THz, with a sensitivity of 123.8 GHz/RIU and 75.6 GHz/RIU, respectively. In addition, an approach to optimizing resonant absorption peaks is explored, which can suppress unwanted absorption generated during the design process by analyzing the energy distribution and directing the current flow on the substrate. Four variables that have a more obvious impact on performance are listed, and the selection and change trend of the numerical values are focused on, fully considering the errors that may be caused by manufacturing and actual use. At the same time, the incident angle and polarization angle are also included in the considered range, and the device shows good stability at these angles. Finally, the influence of the number of resonant rings on the sensing performance is also discussed, and its conclusion has guiding value for optimizing the sensing demand. This new liquid crystal-modulated MS has the advantages of a small size and high sensitivity and is expected to be used for bio-detection, sensing, and so on. All results in this work were obtained with the aid of simulations based on the finite element method.