Ravi Kumar Dwivedi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ravi Kumar Dwivedi has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Avinash Selot
Department of Mechanical Engineering, Maulana Azad National Institute of Technology (MANIT), Bhopal, MP, India
2 shared publications - Amit Suhane
Department of Mechanical Engineering, MANIT, Bhopal, India
1 shared publication - Anoop Pratap Singh
Mechanical Engineering Department, Maulana Azad National Institute of Technology Bhopal, India
1 shared publication - Ayush Srivastav
Department of Mechanical Engineering, Maulana Azad National Institute of Technology, Bhopal, India
1 shared publication - John Ashutosh Santoshi
Department of Orthopaedics, All India Institute of Medical Sciences Bhopal, India
1 shared publication - Prateek Behera
All India Institute of Medical Sciences, Bhopal, 462020, India
1 shared publication
Latest Publications
- Open Access
- 1 March 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3196 (1)
A Custom Lightweight CNN for High-Accuracy Real-Time Detection of Stringing Defects in Fused Filament Fabrication (FFF)
Stringing is one of the most common surface defects in Fused Filament Fabrication (FFF) that degrades part quality and dimensional accuracy. This paper presents a lightweight image-based classification approach using a custom Convolutional Neural Network (CNN) optimized for embedded platforms. A dataset of 1,379 high-resolution (640×640) images was collected using a dual-camera setup on a Creality Ender 3 Pro printer, with defects induced by varying key process parameters through a Design of Experiments (DoE) approach. The proposed CNN achieved 93.8% accuracy, outperforming baseline models such as VGG16 and ResNet50, while maintaining low computational cost. The model was further quantized to TensorFlow Lite and deployed on a Raspberry Pi 4 for real-time defect detection. Results demonstrate that lightweight CNNs can serve as practical, cost-effective tools for automated monitoring of desktop-scale 3D printing.
- 1 March 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3196 (1)
Open AccessA Custom Lightweight CNN for High-Accuracy Real-Time Detection of Stringing Defects in Fused Filament Fabrication (FFF)
Stringing is one of the most common surface defects in Fused Filament Fabrication (FFF) that degrades part quality and dimensional accuracy. This paper presents a lightweight image-based classification approach using a custom Convolutional Neural Network (CNN) optimized for embedded platforms. A dataset of 1,379 high-resolution (640×640) images was collected using a dual-camera setup on a Creality Ender 3 Pro printer, with defects induced by varying key process parameters through a Design of Experiments (DoE) approach. The proposed CNN achieved 93.8% accuracy, outperforming baseline models such as VGG16 and ResNet50, while maintaining low computational cost. The model was further quantized to TensorFlow Lite and deployed on a Raspberry Pi 4 for real-time defect detection. Results demonstrate that lightweight CNNs can serve as practical, cost-effective tools for automated monitoring of desktop-scale 3D printing.
- 28 April 2024
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 58 (6) , 785-793
Finite Element Analysis of Postoperative Stability of Transverse Scaphoid Waist Fracture
Background and Purpose Scaphoid waist fractures are often stabilised with compression screws, Kirschner wires (K-wires), or a combination of both. While clinical and bio-mechanical studies evaluating their utility are available, the ideal configuration of implant that would provide adequate stability to permit early use of the hand is debatable. We examined configurations of a single screw, one screw along with a K-wire, and two K-wires used for a transverse scaphoid waist fracture fixation aiming to assess the stability provided by each in the immediate postoperative period. Methods Computer-aided design (CAD) models of the scaphoid, K-wire, and headless compression screw were created. A transverse fracture was created at the scaphoid waist, and the CAD models of the screw and K-wire were used to fix the fracture in different configurations in a distal to proximal direction. Finite Element Analysis (FEA) was used to examine the strength of configurations when they were subjected to compression and distraction forces. The total maximum deformation (TDef) and factor of safety (FoS) for each configuration were calculated and used as indirect indicators of postoperative stability. Results When a single screw was used, the configurations with the screw directed posteriorly from either centre or anterior had the best combined TDef and FoS values. For one screw and one K-wire, the configuration with screw and K-wire parallel to each other with the screw located along the long axis in the AP projection and anterior to the K-wire in the lateral projection had the best combined TDef and FoS values. When using two K-wires, configurations with the two wires diverging proximally on the lateral projection had the best combined TDef and FoS values. Conclusions When fixing a transverse scaphoid waist fracture with a single screw, the screw directed posteriorly from either the centre or anterior aspect of the distal pole has the best stability, a parallel configuration has the best stability when fixing it using a screw and a K-wire, and divergent configuration has the best stability when fixing it with two K-wires only.
- 28 April 2024
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 58 (6) , 785-793
Finite Element Analysis of Postoperative Stability of Transverse Scaphoid Waist Fracture
Background and Purpose Scaphoid waist fractures are often stabilised with compression screws, Kirschner wires (K-wires), or a combination of both. While clinical and bio-mechanical studies evaluating their utility are available, the ideal configuration of implant that would provide adequate stability to permit early use of the hand is debatable. We examined configurations of a single screw, one screw along with a K-wire, and two K-wires used for a transverse scaphoid waist fracture fixation aiming to assess the stability provided by each in the immediate postoperative period. Methods Computer-aided design (CAD) models of the scaphoid, K-wire, and headless compression screw were created. A transverse fracture was created at the scaphoid waist, and the CAD models of the screw and K-wire were used to fix the fracture in different configurations in a distal to proximal direction. Finite Element Analysis (FEA) was used to examine the strength of configurations when they were subjected to compression and distraction forces. The total maximum deformation (TDef) and factor of safety (FoS) for each configuration were calculated and used as indirect indicators of postoperative stability. Results When a single screw was used, the configurations with the screw directed posteriorly from either centre or anterior had the best combined TDef and FoS values. For one screw and one K-wire, the configuration with screw and K-wire parallel to each other with the screw located along the long axis in the AP projection and anterior to the K-wire in the lateral projection had the best combined TDef and FoS values. When using two K-wires, configurations with the two wires diverging proximally on the lateral projection had the best combined TDef and FoS values. Conclusions When fixing a transverse scaphoid waist fracture with a single screw, the screw directed posteriorly from either the centre or anterior aspect of the distal pole has the best stability, a parallel configuration has the best stability when fixing it using a screw and a K-wire, and divergent configuration has the best stability when fixing it with two K-wires only.
- 23 September 2023
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 45 (10) , 1-25
Machine learning and sensor-based approach for defect detection in MEX additive manufacturing process- A Review
- 23 September 2023
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 45 (10) , 1-25
Machine learning and sensor-based approach for defect detection in MEX additive manufacturing process- A Review
- 1 April 2022
- Published by Pleiades Publishing Ltd in Protection of Metals and Physical Chemistry of Surfaces
- Vol. 58 (2) , 325-338
In the Context of Nano Lubrication, Do Nanoparticles Exhibit Favourable Impacts on All Tribo Surfaces? A Review
Several studies in recent years show that nanoparticles have unlimited potential to enhance the tribological capabilities of lubricating oils. Several reviews are available that elaborate on the importance of nanoparticles in oil lubrication. Since friction is a surficial phenomenon, knowing about nano lubrication without knowing the surface of the tribological members would be only one side of the coin. So, this review focuses on tribological member materials used to evaluate lubricating oil performance. This review also provides detailed elemental information about nano lubrication along with tribological test methods.
- 1 April 2022
- Published by Pleiades Publishing Ltd in Protection of Metals and Physical Chemistry of Surfaces
- Vol. 58 (2) , 325-338
In the Context of Nano Lubrication, Do Nanoparticles Exhibit Favourable Impacts on All Tribo Surfaces? A Review
Several studies in recent years show that nanoparticles have unlimited potential to enhance the tribological capabilities of lubricating oils. Several reviews are available that elaborate on the importance of nanoparticles in oil lubrication. Since friction is a surficial phenomenon, knowing about nano lubrication without knowing the surface of the tribological members would be only one side of the coin. So, this review focuses on tribological member materials used to evaluate lubricating oil performance. This review also provides detailed elemental information about nano lubrication along with tribological test methods.