LGLeon S. Grigoryants

Leon S. Grigoryants

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Leon S. Grigoryants has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative characteristics of facial scanners

    by S.V. Apresyan, A.G. Stepanov, A.P. Zrazhevskaya, V.K. Suonio, L.S. Grigoryants

    The development of digital technologies and devices used in orthopedic dentistry makes it possible to reduce the time for making a prosthesis, reduce costs and improve the quality of manufactured prostheses. One of the most important stages in the production of a prosthesis in a digital protocol is the stage of obtaining digital impressions, which must be as accurate as possible. Goal — to experimentally evaluate the accuracy of three-dimensional images and determine the most suitable models of facial scanners, optimal in terms of price and quality ratio. Materials and Methods.The study examined four scanner models: 3dMDface, ObiScanner, Einstar, and Planmeca ProMax 3D ProFace. The reference model chosen was the stationary scanner VT MINI V2 (Volume Technologies, Russia). A facial mannequin with areas of textured surface was used, and specific points (grooves, indentations) were selected, as these points could be reproduced across different scans: points 1 and 2 represent the outer corners of the eyes, points 3 and 4 correspond to the corners of the mouth, and point 5 indicates the chin. All obtained images were imported into the Exocad software, where each scan was sequentially overlaid onto the reference model scan, and the distance between the scans was measured. Five such studies were conducted for each scanner. Results. The ObiScanner demonstrated the least deviation from the reference scan at a greater number of points: point 1 — 0.069 mm; point 4 — 0.015 mm; point 5 — 0.045 mm, and it is also acceptable in terms of price and availability. The Planmeca ProMax 3D ProFace scanner showed the least deviation from the reference scan at point 3 (0.008 mm), but it is the most expensive among the scanners involved in the study. The 3dMDface scanner had the least deviation at point 2 (0.068 mm) from the reference, but it is the most difficult to access and the second most expensive among the scanners in the study. The Einstar scanner exhibited higher deviation values from the reference scan at each point compared to the other scanners involved in the study, but it has the lowest cost and is easily accessible for purchase.

  • Evaluation of clinical effectiveness of hygiene products for the care of facial prostheses

    by Alexander I. Igumnov, Samvel V. Apresyan, Alexander G. Stepanov, Artavazd E. Kharazyan, Leon S. Grigoryants, Valeria K. Suonio, Anastasia P. Zrazhevskaya

    BACKGROUND: Because of the porous structure of the structural material used in the production of facial prostheses, without careful hygienic care, microbial biofilms may form on the material surface, its color and shape may change, and premature aging may occur. Means for the hygienic care of facial prostheses and research to confirm their clinical effectiveness are crucial in dentistry. AIM: To increase the effectiveness of the hygienic treatment of facial epitheses. METHODS: A single-center randomized study was conducted to assess the clinical effectiveness of hygiene products for the care of facial prostheses. This study involved patients with exenteration of the eye socket, previously prosthetic with adhesive fixation epitheses. The patients were divided into four groups and received different hygienic care methods. Furthermore, during the use of the prosthesis for 14 days and 1 and 3 months, the tissues of the prosthetic bed and hygienic condition of the prosthesis were evaluated, and the quality of life of patients was determined. RESULTS: According to the results of measuring the area of inflammation of tissues of the prosthetic bed of the eye socket at different terms, positive dynamics were found in the groups that used the proposed hygiene products. CONCLUSION: A strong positive correlation (r 0.9) of the average values of the quality of life index, area of inflammation, and hygiene index of the orbital epitheses in the study groups at the appropriate time indicates improved quality of life of patients who used the proposed hygiene products by reducing the amount of bacterial plaque on the surface of the epithesis and, in turn, reducing the area of inflammatory reactions and increasing comfort in wearing the prosthesis.

  • Open Access

    Comparative evaluation of the accuracy of the dental arch display using modern intraoral three-dimensional scanners

    by Irina D. Borodina, Leon S. Grigoryants, Magammed A. Gadzhiev, Svetlana S. Apresyan, Roman V. Batov, Alexander G. Stepanov

    BACKGROUND: At present, modern dentists used dental intraoral three-dimensional (3D) scanners routinely in their daily work. Obtaining an optical 3D image of the teeth and dentition helps avoid errors at the stage of obtaining traditional silicone impressions and significantly reduces the level of discomfort during dental procedures. Intraoral scanner systems are commercially available today. Despite their advantages over traditional silicone impressions, the accuracy of the optical impressions obtained during total and subtotal prosthetics on the upper and lower jaw are still questionable. AIM: This study aimed to evaluate the accuracy of scanning models of the patients dentition obtained using intraoral scanners and to determine the currently available models of digital devices that are optimal in terms of price and quality. MATERIAL AND METHODS: The reference scan (master model) was an optical image of the reference model of the upper jaw of a patient with a full dentition made by additive 3D-printing technology obtained using a laboratory scanner. To level out the shrinkage errors of photopolymerization materials, the resulting model was scanned on the same day using intraoral scanners selected for the study. The obtained scan results were compared with the reference scan of the control group. Based on the measurements made at reference points, the average error value relative to the master model and its precision were calculated for each scanner. In addition to the average values, the error parameters of the scanners in the frontal and chewing sections were calculated, as well as the arc error, which was equal to the difference in the values of the discrepancy at the reference points at which the maximum and minimum values were obtained. The cost and availability of scanners on the domestic market, under the sanctions policy of foreign countries, were also considered. RESULTS: The CEREC Primescan AC scanner showed the best accuracy according to the results of model discrepancies. It has an average error of 13.727.34. The arc error was 18.8 microns, and the discrepancies in the frontal area and chewing area were 18 and 6.8 microns, respectively. 3Shape Trios 3 scanner has the closest accuracy, with an average error of 16.285.94 microns. The error value of Aoralscan 3 was 42.0818.34 microns, its arc accuracy was 65 microns, and the discrepancies in the frontal and chewing areas were 33 and 55.1 microns, respectively. Emerald S Mode C had an average error of 35.8422.29 microns, which was higher than that of Medit i500 and Aoralscan 3; however, Aoralscan 3 showed better precision (18.34 microns versus 22.29 microns). According to the comparison results of the models in the MeshLab program, CEREC Primescan AC showed the smallest median of distances (18 microns). The TRIOS 3 and Emerald S Mode C differed from the standard by an average of 29 microns, and Aoralscan 3 scanners had of 33 microns and Medit i500 had 41 microns. CONCLUSION: The precision of Aoralscan 3 scanner, which is the best among its analogs in the price category, makes it the most affordable scanner for dental surgical, orthodontic, and orthopedic fields. CEREC Primescan AC is the leader of the premium scanners involved in the study and available in the dental market.