Ryusuke Deguchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ryusuke Deguchi has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Isao Hara
Department of Urology Wakayama Medical University Wakayama Japan
3 shared publications - Shimpei Yamashita
Department of Urology Wakayama Medical University Wakayama Japan
3 shared publications - Yasuo Kohjimoto
Department of Urology Wakayama Medical University Wakayama Japan
2 shared publications - Yuya Iwahashi
Department of Forensic Medicine, Wakayama Medical University, 811-1 Kimiidera, Wakayama 641-8509, Japan
2 shared publications - Atsushi Okada
Department of Nephro-urology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
1 shared publication - Kazumi Taguchi
Department of Urology, University of Alabama at Birmingham, Birmingham, USA
1 shared publication
Latest Publications
- 1 February 2024
- Published by SAGE Publications in Journal of Endourology
- Vol. 38 (2) , 186-192
Comparison of Percutaneous Renal Access Between Robot-Assisted Fluoroscopy Guidance Using the Bi-Plane Method and Ultrasound Guidance: A Multicenter Randomized Control Benchtop Study
Purpose: To evaluate the efficacy of supine percutaneous renal access by robot-assisted (RA) fluoroscopy and ultrasound (US) guidance in terms of procedural outcomes and surgeon workload. Methods: We conducted a multicenter, randomized, controlled benchtop study involving 32 urologists using a renal phantom model. RA puncture was performed using the developed version of automated needle targeting with X-ray (ANT-X), which determines the direction of the needle. US puncture was performed under US guidance. The primary endpoint was the single-puncture success rate, and the secondary outcomes were the procedural time for each step, time of fluoroscopic exposure, and workload assessment. Results: The single-puncture success rates were 90.6% and 56.3% for RA and US punctures, respectively (P<0.01). In RA puncture, the median device setup time was 120 s longer, the median total procedural time was 100 s longer, the median time of fluoroscopic exposure was 40 s longer, the median needle puncture time was 17 s shorter, and the distance from the target sphere was 1 cm shorter than those in US puncture (all P<0.01). The mental and physical task workload, effort required by the surgeons, frustration felt by the surgeons, and overall National Aeronautics and Space Administration Task Load Index scores were lower in the RA puncture group than in the US puncture group (P=0.01, P=0.046, P<0.01, P=0.021, and P=<0.01, respectively). Conclusions: RA puncture using ANT-X, which can also be used for puncture in the supine position, offers advantages over renal puncture in terms of accuracy and surgical workload.
- 1 February 2024
- Published by SAGE Publications in Journal of Endourology
- Vol. 38 (2) , 186-192
Comparison of Percutaneous Renal Access Between Robot-Assisted Fluoroscopy Guidance Using the Bi-Plane Method and Ultrasound Guidance: A Multicenter Randomized Control Benchtop Study
Purpose: To evaluate the efficacy of supine percutaneous renal access by robot-assisted (RA) fluoroscopy and ultrasound (US) guidance in terms of procedural outcomes and surgeon workload. Methods: We conducted a multicenter, randomized, controlled benchtop study involving 32 urologists using a renal phantom model. RA puncture was performed using the developed version of automated needle targeting with X-ray (ANT-X), which determines the direction of the needle. US puncture was performed under US guidance. The primary endpoint was the single-puncture success rate, and the secondary outcomes were the procedural time for each step, time of fluoroscopic exposure, and workload assessment. Results: The single-puncture success rates were 90.6% and 56.3% for RA and US punctures, respectively (P<0.01). In RA puncture, the median device setup time was 120 s longer, the median total procedural time was 100 s longer, the median time of fluoroscopic exposure was 40 s longer, the median needle puncture time was 17 s shorter, and the distance from the target sphere was 1 cm shorter than those in US puncture (all P<0.01). The mental and physical task workload, effort required by the surgeons, frustration felt by the surgeons, and overall National Aeronautics and Space Administration Task Load Index scores were lower in the RA puncture group than in the US puncture group (P=0.01, P=0.046, P<0.01, P=0.021, and P=<0.01, respectively). Conclusions: RA puncture using ANT-X, which can also be used for puncture in the supine position, offers advantages over renal puncture in terms of accuracy and surgical workload.
- Open Access
- 22 September 2023
- Published by Wolters Kluwer Health in Current Urology
- Vol. 18 (2) , 148-154
Impact of postoperative sexual function on health-related quality of life after robot-assisted radical prostatectomy
Background: We investigated potential disparities in health-related quality of life, particularly concerning urinary function, between patients with preserved and those with impaired sexual function after robot-assisted radical prostatectomy (RARP). Materials and methods: Between December 2012 and April 2020, 704 men underwent RARP in our hospital. This study included 155 patients with a preoperative 5-item International Index of Erectile Function (IIEF-5) of ≥12 points and an assessable IIEF-5 at 12 months postoperatively. Health-related quality of life was assessed using the 8-item Short-Form Health Survey and Expanded Prostate Cancer Index Composite (EPIC) preoperatively and at 3, 6, and 12 months postoperatively. A logistic regression analysis and Wilcoxon rank sum tests were performed. Results: Patients were grouped according to the median IIEF-5 score 12 months after surgery: those with preserved sexual function (n = 71) and those with impaired sexual function (n = 84). The mental component summary of the 8-item Short-Form Health Survey was better in the group with preserved sexual function at 6 months postoperatively than in the group with impaired sexual function (p < 0.01). In the EPIC, the group with preserved sexual function performed better not only in the sexual domain but also in the urinary domain at all time points compared with the group with impaired sexual function (p < 0.01). In the comparison of the urinary subdomains of the EPIC, there were no significant differences in urinary function or incontinence, but there were significant differences in urinary distress and irritative/obstructive scores (p < 0.01). Conclusions: Patients with preserved postoperative sexual function after RARP showed better urinary function than those with impaired sexual function. Hence, preserved sexual function is closely associated with urinary function.
- 22 September 2023
- Published by Wolters Kluwer Health in Current Urology
- Vol. 18 (2) , 148-154
Open AccessImpact of postoperative sexual function on health-related quality of life after robot-assisted radical prostatectomy
Background: We investigated potential disparities in health-related quality of life, particularly concerning urinary function, between patients with preserved and those with impaired sexual function after robot-assisted radical prostatectomy (RARP). Materials and methods: Between December 2012 and April 2020, 704 men underwent RARP in our hospital. This study included 155 patients with a preoperative 5-item International Index of Erectile Function (IIEF-5) of ≥12 points and an assessable IIEF-5 at 12 months postoperatively. Health-related quality of life was assessed using the 8-item Short-Form Health Survey and Expanded Prostate Cancer Index Composite (EPIC) preoperatively and at 3, 6, and 12 months postoperatively. A logistic regression analysis and Wilcoxon rank sum tests were performed. Results: Patients were grouped according to the median IIEF-5 score 12 months after surgery: those with preserved sexual function (n = 71) and those with impaired sexual function (n = 84). The mental component summary of the 8-item Short-Form Health Survey was better in the group with preserved sexual function at 6 months postoperatively than in the group with impaired sexual function (p < 0.01). In the EPIC, the group with preserved sexual function performed better not only in the sexual domain but also in the urinary domain at all time points compared with the group with impaired sexual function (p < 0.01). In the comparison of the urinary subdomains of the EPIC, there were no significant differences in urinary function or incontinence, but there were significant differences in urinary distress and irritative/obstructive scores (p < 0.01). Conclusions: Patients with preserved postoperative sexual function after RARP showed better urinary function than those with impaired sexual function. Hence, preserved sexual function is closely associated with urinary function.
- Open Access
- 10 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (4) , 1409
Dynamic Changes in Fluid Temperatures during Laser Irradiation Using Various Laser Modes: A Thermography-Based In Vitro Phantom Study
The differences in dynamic thermal changes during laser lithotripsy between various laser pulse modes are unclear. We used thermography to evaluate the temporal changes in high-temperature areas during laser activation in order to compare different laser pulse modes. An unroofed artificial kidney model was used for the experiments. The laser fired for 60 s with a laser setting of 0.4 J/60 Hz in the following four different laser pulse modes without saline irrigation: short pulse mode (SPM), long pulse mode (LPM), virtual basket mode (VBM) and Moses mode (MM). Using the first 30 s of moving images, we compared the ratio of a high-temperature area of >43 °C to the total area every 5 seconds. The dynamic changes in fluid temperatures were shown to be different between the laser pulse modes. The extent of the high-temperature areas during the laser activation was large in the LPM and MM compared with the SPM and VBM. While the high-temperature areas expanded in an anterior direction in the early laser irradiation period using the LPM, they spread in a posterior direction in the early laser activation period using the MM. Although only the temperature profile in one specific plane was investigated, these results are considered useful for preventing thermal injuries during retrograde intrarenal surgeries.
- 10 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (4) , 1409
Open AccessDynamic Changes in Fluid Temperatures during Laser Irradiation Using Various Laser Modes: A Thermography-Based In Vitro Phantom Study
The differences in dynamic thermal changes during laser lithotripsy between various laser pulse modes are unclear. We used thermography to evaluate the temporal changes in high-temperature areas during laser activation in order to compare different laser pulse modes. An unroofed artificial kidney model was used for the experiments. The laser fired for 60 s with a laser setting of 0.4 J/60 Hz in the following four different laser pulse modes without saline irrigation: short pulse mode (SPM), long pulse mode (LPM), virtual basket mode (VBM) and Moses mode (MM). Using the first 30 s of moving images, we compared the ratio of a high-temperature area of >43 °C to the total area every 5 seconds. The dynamic changes in fluid temperatures were shown to be different between the laser pulse modes. The extent of the high-temperature areas during the laser activation was large in the LPM and MM compared with the SPM and VBM. While the high-temperature areas expanded in an anterior direction in the early laser irradiation period using the LPM, they spread in a posterior direction in the early laser activation period using the MM. Although only the temperature profile in one specific plane was investigated, these results are considered useful for preventing thermal injuries during retrograde intrarenal surgeries.