Lanxin Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lanxin Peng has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Changzheng Chen
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, No. 3888, Dong Nanhu Road, Changchun 130033, China
1 shared publication - Changzheng Chen
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
1 shared publication - Fengfeng Shu
Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP), Chinese Academy of Sciences, Changchun 130033, China
1 shared publication - Hongbo Zhao
School of Instrument Seicence and Opto-Electronics Engineering, Hefei University of Technology, Hefei 230009, China
1 shared publication - Junyu Dong
State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
1 shared publication - Xiaodong Sui
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
1 shared publication
Latest Publications
- Open Access
Active Support Correction and Variable Triangular Layout Optimization for an Annular Thin Mirror in Optical Remote-Sensing Systems
Surface-figure stability is essential to high-resolution optical remote-sensing systems that employ lightweight annular primary mirrors. This study proposes a variable triangular active support layout for a 660 mm annular thin mirror with a 100 mm central aperture. The layout is parameterized within a one-sixth annular sector and constructed over the full aperture by six-fold rotational replication. Finite-element influence functions, Annular Zernike modal fitting, and Kriging surrogate modeling are integrated to assess modal controllability while reducing the cost of repeated finite-element analyses. The objective function accounts for surface-figure maintenance under gravity, correction residuals for representative low-order Annular Zernike modes, geometric constraints, and the actuator-force limit. Optimization is performed using the covariance matrix adaptation evolution strategy (CMA-ES), followed by local refinement. For a 36-point support configuration, the optimized variable triangular layout satisfies the 12.66 nm RMS residual requirement under axial and radial gravity and for all representative Z4–Z11 target surfaces. Among the annular, triangular, square, hexagonal, Fibonacci, and proposed layouts, the proposed layout yields the lowest composite objective-function value, a mean corrected RMS residual of 2.15 nm, and an effective response-matrix rank of 35. Monte Carlo simulations with independent ±1 mm support-position perturbations further demonstrate its robustness to installation errors.
Open AccessActive Support Correction and Variable Triangular Layout Optimization for an Annular Thin Mirror in Optical Remote-Sensing Systems
Surface-figure stability is essential to high-resolution optical remote-sensing systems that employ lightweight annular primary mirrors. This study proposes a variable triangular active support layout for a 660 mm annular thin mirror with a 100 mm central aperture. The layout is parameterized within a one-sixth annular sector and constructed over the full aperture by six-fold rotational replication. Finite-element influence functions, Annular Zernike modal fitting, and Kriging surrogate modeling are integrated to assess modal controllability while reducing the cost of repeated finite-element analyses. The objective function accounts for surface-figure maintenance under gravity, correction residuals for representative low-order Annular Zernike modes, geometric constraints, and the actuator-force limit. Optimization is performed using the covariance matrix adaptation evolution strategy (CMA-ES), followed by local refinement. For a 36-point support configuration, the optimized variable triangular layout satisfies the 12.66 nm RMS residual requirement under axial and radial gravity and for all representative Z4–Z11 target surfaces. Among the annular, triangular, square, hexagonal, Fibonacci, and proposed layouts, the proposed layout yields the lowest composite objective-function value, a mean corrected RMS residual of 2.15 nm, and an effective response-matrix rank of 35. Monte Carlo simulations with independent ±1 mm support-position perturbations further demonstrate its robustness to installation errors.
- Open Access
Design and Error Analysis of an Optical Measurement System for the Wavefront of Large-Aperture Segmented Mirror
To better meet the wavefront measurement requirements for large-aperture segmented mirrors after in-orbit deployment, this paper designs a measurement system based on an optical camera and targets. This system utilizes photogrammetry principles to measure target positions, fit the wavefront of the segmented mirror, and form a closed-loop control with the calibration mechanism. Based on the wavefront measurement range and accuracy requirements during the coarse calibration phase of the segmented mirror, the optical system was first designed. The measurement camera features a 16° × 12° rectangular field of view with a 100 mm focal length, achieving near-diffraction-limited imaging quality. The structural fundamental frequency of the measurement camera exceeds 400 Hz. Under a 4 °C temperature rise environment, the surface error of the optical lens remains better than 1/80. Based on error theory, a quantitative analysis of error sources and their impact on target position measurement accuracy was conducted, yielding theoretical measurement errors of ±0.0853 mm in the Z-direction and ±0.1525 mm in the X-direction. Through focal length calibration and imaging tests of the prototype, the measurement camera achieved a modulation transfer function greater than 0.11 with excellent imaging quality. With a focal length of 101.356 mm and a measurement range exceeding ±4 mm, it meets design requirements. Finite element simulation and Monte Carlo methods analyzed wavefront fitting accuracy under different operating conditions, yielding peak-to-valley values of 0.397 mm and root mean square values of 0.073 mm. The wavefront measurement system designed in this paper meets the structural rigidity and temperature adaptability requirements for in-orbit measurement systems. The prototype’s field of view satisfies the wavefront measurement range requirements, the camera’s focal length meets design specifications with good imaging quality, and the wavefront measurement deviation meets the accuracy requirements for the coarse calibration phase. Compared to current wavefront measurement systems, the proposed system significantly expands the measurement range, offering a novel wavefront measurement method for coarse calibration of tiled mirrors.Open AccessDesign and Error Analysis of an Optical Measurement System for the Wavefront of Large-Aperture Segmented Mirror
To better meet the wavefront measurement requirements for large-aperture segmented mirrors after in-orbit deployment, this paper designs a measurement system based on an optical camera and targets. This system utilizes photogrammetry principles to measure target positions, fit the wavefront of the segmented mirror, and form a closed-loop control with the calibration mechanism. Based on the wavefront measurement range and accuracy requirements during the coarse calibration phase of the segmented mirror, the optical system was first designed. The measurement camera features a 16° × 12° rectangular field of view with a 100 mm focal length, achieving near-diffraction-limited imaging quality. The structural fundamental frequency of the measurement camera exceeds 400 Hz. Under a 4 °C temperature rise environment, the surface error of the optical lens remains better than 1/80. Based on error theory, a quantitative analysis of error sources and their impact on target position measurement accuracy was conducted, yielding theoretical measurement errors of ±0.0853 mm in the Z-direction and ±0.1525 mm in the X-direction. Through focal length calibration and imaging tests of the prototype, the measurement camera achieved a modulation transfer function greater than 0.11 with excellent imaging quality. With a focal length of 101.356 mm and a measurement range exceeding ±4 mm, it meets design requirements. Finite element simulation and Monte Carlo methods analyzed wavefront fitting accuracy under different operating conditions, yielding peak-to-valley values of 0.397 mm and root mean square values of 0.073 mm. The wavefront measurement system designed in this paper meets the structural rigidity and temperature adaptability requirements for in-orbit measurement systems. The prototype’s field of view satisfies the wavefront measurement range requirements, the camera’s focal length meets design specifications with good imaging quality, and the wavefront measurement deviation meets the accuracy requirements for the coarse calibration phase. Compared to current wavefront measurement systems, the proposed system significantly expands the measurement range, offering a novel wavefront measurement method for coarse calibration of tiled mirrors. - Open Access
- 10 February 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (2) , 420
A Meniscus Multifocusing Compound Eye Camera Based on Negative Pressure Forming Technology
To meet the challenge of preparing a high-resolution compound eye, this paper proposes a multi-focal-length meniscus compound eye based on MEMS negative pressure molding technology. The aperture is increased, a large field of view angle of 101.14° is obtained, and the ommatidia radius of each stage is gradually increased from 250 μm to 440 μm. A meniscus structure is used to improve the imaging quality of the marginal compound eye so that its resolution can reach 36.00 lp/mm. The prepared microlenses have a uniform shape and a smooth surface, and both panoramic image stitching and moving object tracking are achieved. This technology has great potential for application in many fields, including automatic driving, machine vision, and medical endoscopy.
- 10 February 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (2) , 420
Open AccessA Meniscus Multifocusing Compound Eye Camera Based on Negative Pressure Forming Technology
To meet the challenge of preparing a high-resolution compound eye, this paper proposes a multi-focal-length meniscus compound eye based on MEMS negative pressure molding technology. The aperture is increased, a large field of view angle of 101.14° is obtained, and the ommatidia radius of each stage is gradually increased from 250 μm to 440 μm. A meniscus structure is used to improve the imaging quality of the marginal compound eye so that its resolution can reach 36.00 lp/mm. The prepared microlenses have a uniform shape and a smooth surface, and both panoramic image stitching and moving object tracking are achieved. This technology has great potential for application in many fields, including automatic driving, machine vision, and medical endoscopy.