    Evaluation of Pipe Thickness by Magnetic Hammer Test with a Tunnel Magnetoresistive Sensor

    by Jun Ito, Yudai Igarashi, Ryota Odagiri, Shigetaka Suzuki, Hiroshi Wagatsuma, Kazuhiro Sugiyama, Mikihiko Oogane

    A new nondestructive inspection method, the magnetic hammer test (MHT), which uses a compact and highly sensitive tunnel magnetoresistance (TMR) sensor, is proposed. This method complements the magnetic flux leakage method and eliminates the issues of the hammer test. It can therefore detect weak magnetic fields generated by the natural vibration of a pipe with a high signal-to-noise ratio. In this study, several steel pipes with different wall thicknesses were measured using a TMR sensor to demonstrate the superiority of MHT. The results of the measurement show that wall thickness can be evaluated with the accuracy of several tens of microns from the change in the natural vibration frequency of the specimen pipe. The pipes were also inspected underwater using a waterproofed TMR sensor, which demonstrated an accuracy of less than 100 μm. The validity of these results was by simulating the shielding of magnetic fields and vibration of the pipes with the finite element method (FEM) analysis. The proposed noncontact, fast, and accurate method for thickness testing of long-distance pipes will contribute to unmanned, manpower-saving nondestructive testing (NDT) in the future.


  • Open Access

    Development of Magnetocardiograph without Magnetically Shielded Room Using High-Detectivity TMR Sensors

    by Koshi Kurashima, Makoto Kataoka, Takafumi Nakano, Kosuke Fujiwara, Seiichi Kato, Takenobu Nakamura, Masaki Yuzawa, Masanori Masuda, Kakeru Ichimura, Shigeki Okatake, et al.

    A magnetocardiograph that enables the clear observation of heart magnetic field mappings without magnetically shielded rooms at room temperatures has been successfully manufactured. Compared to widespread electrocardiographs, magnetocardiographs commonly have a higher spatial resolution, which is expected to lead to early diagnoses of ischemic heart disease and high diagnostic accuracy of ventricular arrhythmia, which involves the risk of sudden death. However, as the conventional superconducting quantum interference device (SQUID) magnetocardiographs require large magnetically shielded rooms and huge running costs to cool the SQUID sensors, magnetocardiography is still unfamiliar technology. Here, in order to achieve the heart field detectivity of 1.0 pT without magnetically shielded rooms and enough magnetocardiography accuracy, we aimed to improve the detectivity of tunneling magnetoresistance (TMR) sensors and to decrease the environmental and sensor noises with a mathematical algorithm. The magnetic detectivity of the TMR sensors was confirmed to be 14.1 pTrms on average in the frequency band between 0.2 and 100 Hz in uncooled states, thanks to the original multilayer structure and the innovative pattern of free layers. By constructing a sensor array using 288 TMR sensors and applying the mathematical magnetic shield technology of signal space separation (SSS), we confirmed that SSS reduces the environmental magnetic noise by −73 dB, which overtakes the general triple magnetically shielded rooms. Moreover, applying digital processing that combined the signal average of heart magnetic fields for one minute and the projection operation, we succeeded in reducing the sensor noise by about −23 dB. The heart magnetic field resolution measured on a subject in a laboratory in an office building was 0.99 pTrms and obtained magnetocardiograms and current arrow maps as clear as the SQUID magnetocardiograph does in the QRS and ST segments. Upon utilizing its superior spatial resolution, this magnetocardiograph has the potential to be an important tool for the early diagnosis of ischemic heart disease and the risk management of sudden death triggered by ventricular arrhythmia.