Anastasia Shpikina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anastasia Shpikina has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Veccia
Young Academic Urologists (YAU) Working Group in Urotechnology of the European Association of Urology, 30016 Arnhem, The Netherlands
1 shared publication - Andrey Morozov
Sechenov First Moscow State Medical University (Sechenov University)
1 shared publication - Camilla Azilgareeva
Institute for Urology and Reproductive Health, Sechenov University, 119991 Moscow, Russia
1 shared publication - Dmitry Enikeev
Institute for Urology and Reproductive Health, Sechenov University, Moscow, Russia
1 shared publication - Enrico Checcucci
Department of Surgery, Candiolo Cancer Institute, FPO-IRCCS, Candiolo, Turin, Italy -
1 shared publication - German E. Krupinov
I.M. Sechenov First Moscow State Medical University (Sechenov University)
1 shared publication
Latest Publications
- Open Access
Robot-Assisted Magnetic Resonance Imaging-Targeted versus Systematic Prostate Biopsy; Systematic Review and Meta-Analysis
Introduction: Robot-assisted devices have been recently developed for use in prostate biopsy. However, it is possible advantages over standard biopsy remain unclear. We aimed to assess the diagnostic performance and safety of robot-assisted targeted (RA-TB) and systematic prostate biopsies (RA-SB). Methods: A systematic literature search was performed in MEDLINE and Scopus databases. The detailed search strategy is available at Prospero (CRD42021269290). The primary outcome was the clinically significant prostate cancer (PCa) detection rate. The secondary outcomes included the overall detection rate of PCa, cancer detection rate per core, and complications. Results: The clinically significant cancer detection rate, overall cancer detection rate, and “per patient” did not significantly differ between RA-TB and RA-SB [OR = 1.02 (95% CI 0.83; 1.26), p = 0.05, I2 = 62% and OR = 0.95 (95% CI 0.78; 1.17), p = 0.17, I2 = 40%, respectively]. There were no differences in the clinically insignificant cancer detection rate “per patient” between RA-TB and RA-SB [OR = 0.81 (95% CI 0.54; 1.21), p = 0.31, I2 = 0%]. RA-TB had a significantly higher cancer detection rate “per core” [OR = 3.01 (95% CI 2.77; 3.27), p < 0.0001, I2 = 96%]. Conclusion: RA-TB and RA-SB are both technically feasible and have comparable clinical significance and overall PCa detection rates.
Open AccessRobot-Assisted Magnetic Resonance Imaging-Targeted versus Systematic Prostate Biopsy; Systematic Review and Meta-Analysis
Introduction: Robot-assisted devices have been recently developed for use in prostate biopsy. However, it is possible advantages over standard biopsy remain unclear. We aimed to assess the diagnostic performance and safety of robot-assisted targeted (RA-TB) and systematic prostate biopsies (RA-SB). Methods: A systematic literature search was performed in MEDLINE and Scopus databases. The detailed search strategy is available at Prospero (CRD42021269290). The primary outcome was the clinically significant prostate cancer (PCa) detection rate. The secondary outcomes included the overall detection rate of PCa, cancer detection rate per core, and complications. Results: The clinically significant cancer detection rate, overall cancer detection rate, and “per patient” did not significantly differ between RA-TB and RA-SB [OR = 1.02 (95% CI 0.83; 1.26), p = 0.05, I2 = 62% and OR = 0.95 (95% CI 0.78; 1.17), p = 0.17, I2 = 40%, respectively]. There were no differences in the clinically insignificant cancer detection rate “per patient” between RA-TB and RA-SB [OR = 0.81 (95% CI 0.54; 1.21), p = 0.31, I2 = 0%]. RA-TB had a significantly higher cancer detection rate “per core” [OR = 3.01 (95% CI 2.77; 3.27), p < 0.0001, I2 = 96%]. Conclusion: RA-TB and RA-SB are both technically feasible and have comparable clinical significance and overall PCa detection rates.