HZHaining Zhang

Haining Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Haining Zhang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Hao Xu

    Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, China

    3 shared publications
  • Wenzhe Wang

    Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, China

    2 shared publications
  • Xinzhe Lu

    Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, China

    2 shared publications
  • Zian Zhang

    Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, China

    2 shared publications
  • Chengyu Lv

    Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, China

    1 shared publication
  • Hao Xu

    Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, People’s Republic of China

    1 shared publication

Latest Publications

  • Open Access

    A new designed full process coverage robot-assisted total hip arthroplasty: a multicentre randomized clinical trial

    by Xinzhe Lu, Zian Zhang, Hao Xu, Wenzhe Wang, Haining Zhang

    Objective: To compare the effect of a new complete robot-assisted total hip arthroplasty (RA-THA) with that of the manual total hip arthroplasty (MTHA) and to verify the accuracy and safety of the former. Methods: Overall, 148 patients were enroled from 3 March 2021 to 28 December 2021 in this study and classified into RA-THA (n=74 patients) and MTHA (n=74 patients) groups. The sex, age, operative side, BMI, diagnosis, other basic information, operative time, acetabular prosthesis anteversion and inclination, femoral prosthesis anteversion and angulation, femoral prosthesis filling rate, leg length discrepancy (LLD), Harris hip score, and visual analogue scale (VAS) score of the two groups were compared. Results: No significant differences were observed in the two groups regarding sex, age, operative side, BMI, diagnosis, Harris hip score, VAS score, acetabular inclination, acetabular prosthesis anteversion, femoral prosthesis anteversion, combined anteversion, and femoral prosthesis filling rate (P>0.05). The operative time was significantly longer in the RA-THA group than in the MTHA group (106.71±25.22 min vs. 79.42±16.16 min; t=7.30, PP<0.05). Conclusion: The complete RA-THA has some advantages over the traditional procedure in restoring the lower limb length and controlling the femoral prosthesis angulation. Thus, this study verifies the accuracy and safety of the robot-assisted system.


  • Open Access

    Accuracy and safety of a new robotic arm for both femoral and acetabular side in total hip arthroplasty: a cadaveric study

    by Xinzhe Lu, Zian Zhang, Wenzhe Wang, Hao Xu, Haining Zhang

    Background: To investigate the accuracy and safety of a newly constructed robotic arm which can cover the whole process of THA, we performed a series of robot-assisted total hip replacement on the cadaver. Methods: Fifteen frozen cadaveric specimens (30 hips) were used for this study. In this investigation, united hip system and Longwell robotic-assisted system were used. The entire lower limb was CT scanned prior to surgery. The 3D model was produced based on CT data; the site of the prosthesis, including acetabular anteversion, inclination angle, and the position of femoral prosthesis, was planned. With the assistance of a robotic arm, the surgeon changed the parameters based on the preoperative plan and the actual condition during surgery, and completed the whole procedure. Following surgery, we measured the acetabular anteversion angle, acetabular inclination angle, femur anteversion angle, combined anteversion angle, stem angulation, and canal fill ratio. Results: The parameters proved that the acetabular anteversion angle was 16.85 ± 3.00°, the acetabular inclination angle was 40.38 ± 5.37°, femur anteversion angle was 15.90 ± 9.01°, combined anteversion angle was 32.75 ± 9.03°, stem angulation was 1.84 ± 0.99°, and leg length discrepancy was 2.47 ± 1.43 mm. The canal fill ratio (CFR) of femoral prosthesis of osteotomy line in sagittal section is 99.72 ± 1.54% and in coronal section is 62.94 ± 8.91%; below osteotomy line 2.5 cm in sagittal section is 100.00% and in coronal section is 81.48 ± 12.94%; below osteotomy line 7.5 cm in sagittal section is 59.51 ± 12.94% and in coronal section is 89.79 ± 11.13%; femoral shaft isthmus in sagittal section is 56.41 ± 13.80% and in coronal section is 84.95 ± 15.17%. Conclusion: The accuracy and safety of this novel robotic arm are suitable for preparing both the acetabular and femoral sides, providing evidence for clinical trial.


  • Open Access

    Accuracy and safety of a new Robotic arm for both femoral and acetabular side in Total Hip Arthroplasty: A Cadaveric Study

    by Xinzhe Lu, Zian Zhang, Wenzhe Wang, Hao Xu, Haining Zhang

    Background To investigate the accuracy and safety of a newly constructed robotic arm which can cover the whole process of THA, we performed a series of robot-assisted total hip replacement on the cadaver. Methods Fifteen frozen cadaveric specimens (30 hips) were used for this study. In this investigation, United hip system and Longwell robotic-assisted system were used. The entire lower limb was CT scanned prior to surgery. The 3D model was produced based on CT data, the site of the prosthesis, including acetabular anteversion, inclination angle, and the position of femoral prosthesis were planned. With the assistance of a robotic arm, the surgeon changed the parameters based on the preoperative plan and the actual condition during surgery, and completed the whole procedure. Following surgery, we measured the acetabular anteversion angle, acetabular inclination angle, femur anteversion angle, combined anteversion angle, stem angulation, and canal-fill-ratio. Results The parameters proved that the acetabular anteversion angle was 16.85 ± 3.00 °, and the acetabular inclination angle was 40.38 ± 5.37 °, femur anteversion angle was 15.90 ± 9.01 °, combined anteversion angle was 32.75 ± 9.03 °, stem angulation was 1.84 ± 0.99 °, leg length discrepancy was 2.47 ± 1.43mm. The canal-fill-rate (CFR) of femoral prosthesis was also satisfactory. Conclusion The accuracy and safety of this novel robotic arm are suitable for preparing both the acetabular and femoral sides, providing evidence for clinical trial.