LLLiu Lu

Liu Lu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Liu Lu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Xiaohu Yang

    Institute of the Building Environment & Sustainability Technology, School of Human Settlements and Civil Engineering, Xi’an Jiaotong University, Xi’an 710049, China

    2 shared publications
  • Chenlei Yu

    State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace, Xi'an Jiaotong University, Xi'an 710049, China

    1 shared publication
  • Moxiao Li

    State Key Laboratory of Mechanics and Control of Mechanical Structures, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China; Nanjing 210016, China

    1 shared publication
  • Pan Luo

    Shaanxi Yanchang Petroleum (Group) Co., Ltd., Xi’an 710065, China

    1 shared publication
  • Qihui Wang

    National Innovation Platform (Center) for Industry-Education Integration of Energy Storage Technology, Xi’an Jiaotong University, Xi’an 710049, China

    1 shared publication
  • Sandra K. S. Boetcher

    Department of Mechanical Engineering, Embry-Riddle Aeronautical University

    1 shared publication

Latest Publications

  • Open Access

    Effects of Formation and Injection Parameters on Multi-Field Damage Evolution of Hot Dry Rock During CO2 Fracturing

    by Xiao Sun, Pan Luo, Xing Guo, Liu Lu, Qihui Wang, Xiaohu Yang

    Low-temperature CO2 fracturing generates obvious thermal tensile disturbance via reservoir–fluid temperature difference, which is an efficient stimulation technology for hot dry rock (HDR). In this work, a two-dimensional plane-strain thermo-hydro-mechanical-damage (THMD) coupling numerical model considering granite mechanical heterogeneity is established, and seven single-variable simulation cases are designed to quantitatively analyze the joint effects of fluid type, reservoir temperature, injection parameters, and in situ stress on HDR damage, temperature-pore pressure field, and system energy evolution. The results show that the damaged area induced by CO2 injection is five times larger than that of water under identical baseline conditions. Raising reservoir temperature or injection pressure significantly strengthens thermo-seepage coupling effects, with the maximum damaged area ratio increased by over 220%. Higher CO2 injection pressure and lower injection temperature weaken thermal stress and restrain fracture propagation; an anisotropic stress field only produces a single main fracture without complex branch networks. Energy analysis indicates injection pressure dominates the accumulation of HDR strain potential energy, and the potential energy under high injection pressure can reach more than 11 times the baseline value. This study quantitatively analyzes the individual influences of fluid type, reservoir temperature, injection temperature, injection pressure, and in situ stress anisotropy on HDR damage evolution, and discusses their combined effects.

  • Analytical Fractal Model for Effective Thermal Conductivity of Open-Cell Metallic Foams With Coated Hollow Ligaments

    by Tian Xiao, Liu Lu, Chenlei Yu, Sandra K. S. Boetcher, Xiaohu Yang, Moxiao Li, Tian Jian Lu

    Coating the hollow ligaments of open-cell (fluid-through) metallic foams (MFs) fabricated via the sintering route with a thin layer of graphene can improve the effective thermal conductivity (ETC) of the foam without significantly increasing its flow resistance, potentially important for thermal storage applications. However, the Euclidean geometry cannot accurately depict the random distribution of pores within MFs. To this end, the present study aims to analyze how such thin coatings affect the ETC of MF by employing the fractal theory to depict the random distribution of its open pores. Subsequently, a cubic representative structure is chosen for self-similar pores in the fractal to establish a correlation between the geometric parameters of MF and its fractal dimension. Upon determining the thermal resistance provided a representative structure of the foam having coated hollow ligaments, its ETC is derived as a function of fractal dimension, dimensionless parameters of pore size, porosity, and thermal conductivity of relevant materials (e.g., ligaments, coatings, and filling medium). For validation, existing experimental data are used to compare with analytical predictions, with good agreement achieved. It is demonstrated that the ligament hollowness weakens the thermal conduction of MFs. In addition, when the coating has a thermal conductivity greater than that of ligament, the coating enhances the ability of the foam to conduct heat. Although the ligament hollowness and coating thickness are imperative factors affecting the ETC, the material makes of ligament and coating plays a decisive role in the ETC.