Shijia Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shijia Yang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Dayin Wang
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
2 shared publications - Jianlong Zhao
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
2 shared publications - Ning Wang
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
2 shared publications - Shilun Feng
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, CHINA
2 shared publications - Yuan Luo
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
2 shared publications - Gaozhe Cai
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
1 shared publication
Latest Publications
- Open Access
- 6 April 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (4) , 177
A Novel DNA Synthesis Platform Design with High-Throughput Paralleled Addressability and High-Density Static Droplet Confinement
Using DNA as the next-generation medium for data storage offers unparalleled advantages in terms of data density, storage duration, and power consumption as compared to existing data storage technologies. To meet the high-speed data writing requirements in DNA data storage, this paper proposes a novel design for an ultra-high-density and high-throughput DNA synthesis platform. The presented design mainly leverages two functional modules: a dynamic random-access memory (DRAM)-like integrated circuit (IC) responsible for electrode addressing and voltage supply, and the static droplet array (SDA)-based microfluidic structure to eliminate any reaction species diffusion concern in electrochemical DNA synthesis. Through theoretical analysis and simulation studies, we validate the effective addressing of 10 million electrodes and stable, adjustable voltage supply by the integrated circuit. We also demonstrate a reaction unit size down to 3.16 × 3.16 μm2, equivalent to 10 million/cm2, that can rapidly and stably generate static droplets at each site, effectively constraining proton diffusion. Finally, we conducted a synthesis cycle experiment by incorporating fluorescent beacons on a microfabricated electrode array to examine the feasibility of our design.
- 6 April 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (4) , 177
Open AccessA Novel DNA Synthesis Platform Design with High-Throughput Paralleled Addressability and High-Density Static Droplet Confinement
Using DNA as the next-generation medium for data storage offers unparalleled advantages in terms of data density, storage duration, and power consumption as compared to existing data storage technologies. To meet the high-speed data writing requirements in DNA data storage, this paper proposes a novel design for an ultra-high-density and high-throughput DNA synthesis platform. The presented design mainly leverages two functional modules: a dynamic random-access memory (DRAM)-like integrated circuit (IC) responsible for electrode addressing and voltage supply, and the static droplet array (SDA)-based microfluidic structure to eliminate any reaction species diffusion concern in electrochemical DNA synthesis. Through theoretical analysis and simulation studies, we validate the effective addressing of 10 million electrodes and stable, adjustable voltage supply by the integrated circuit. We also demonstrate a reaction unit size down to 3.16 × 3.16 μm2, equivalent to 10 million/cm2, that can rapidly and stably generate static droplets at each site, effectively constraining proton diffusion. Finally, we conducted a synthesis cycle experiment by incorporating fluorescent beacons on a microfabricated electrode array to examine the feasibility of our design.
- Open Access
- 4 April 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (4) , 174
A Novel Microfluidic Strategy for Efficient Exosome Separation via Thermally Oxidized Non-Uniform Deterministic Lateral Displacement (DLD) Arrays and Dielectrophoresis (DEP) Synergy
Exosomes, with diameters ranging from 30 to 150 nm, are saucer-shaped extracellular vesicles (EVs) secreted by various type of human cells. They are present in virtually all bodily fluids. Owing to their abundant nucleic acid and protein content, exosomes have emerged as promising biomarkers for noninvasive molecular diagnostics. However, the need for exosome separation purification presents tremendous technical challenges due to their minuscule size. In recent years, microfluidic technology has garnered substantial interest as a promising alternative capable of excellent separation performance, reduced reagent consumption, and lower overall device and operation costs. In this context, we hereby propose a novel microfluidic strategy based on thermally oxidized deterministic lateral displacement (DLD) arrays with tapered shapes to enhance separation performance. We have achieved more than 90% purity in both polystyrene nanoparticle and exosome experiments. The use of thermal oxidation also significantly reduces fabrication complexity by avoiding the use of high-precision lithography. Furthermore, in a simulation model, we attempt to integrate the use of dielectrophoresis (DEP) to overcome the size-based nature of DLD and distinguish particles that are close in size but differ in biochemical compositions (e.g., lipoproteins, exomeres, retroviruses). We believe the proposed strategy heralds a versatile and innovative platform poised to enhance exosome analysis across a spectrum of biochemical applications.
- 4 April 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (4) , 174
Open AccessA Novel Microfluidic Strategy for Efficient Exosome Separation via Thermally Oxidized Non-Uniform Deterministic Lateral Displacement (DLD) Arrays and Dielectrophoresis (DEP) Synergy
Exosomes, with diameters ranging from 30 to 150 nm, are saucer-shaped extracellular vesicles (EVs) secreted by various type of human cells. They are present in virtually all bodily fluids. Owing to their abundant nucleic acid and protein content, exosomes have emerged as promising biomarkers for noninvasive molecular diagnostics. However, the need for exosome separation purification presents tremendous technical challenges due to their minuscule size. In recent years, microfluidic technology has garnered substantial interest as a promising alternative capable of excellent separation performance, reduced reagent consumption, and lower overall device and operation costs. In this context, we hereby propose a novel microfluidic strategy based on thermally oxidized deterministic lateral displacement (DLD) arrays with tapered shapes to enhance separation performance. We have achieved more than 90% purity in both polystyrene nanoparticle and exosome experiments. The use of thermal oxidation also significantly reduces fabrication complexity by avoiding the use of high-precision lithography. Furthermore, in a simulation model, we attempt to integrate the use of dielectrophoresis (DEP) to overcome the size-based nature of DLD and distinguish particles that are close in size but differ in biochemical compositions (e.g., lipoproteins, exomeres, retroviruses). We believe the proposed strategy heralds a versatile and innovative platform poised to enhance exosome analysis across a spectrum of biochemical applications.
- Open Access
- 15 February 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (2) , 274
Construction and Manipulation of Serial Gradient Dilution Array on a Microfluidic Slipchip for Screening and Characterizing Inhibitors against Human Pancreatic Lipase
Obesity is one of the foremost public health concerns. Human pancreatic lipase (hPL), a crucial digestive enzyme responsible for the digestion of dietary lipids in humans, has been validated as an important therapeutic target for preventing and treating obesity. The serial dilution technique is commonly used to generate solutions with different concentrations and can be easily modified for drug screening. Conventional serial gradient dilution is often performed with tedious multiple manual pipetting steps, where it is difficult to precisely control fluidic volumes at low microliter levels. Herein, we presented a microfluidic SlipChip that enabled formation and manipulation of serial dilution array in an instrument-free manner. With simple slipping steps, the compound solution could be diluted to seven gradients with the dilution ratio of 1:1 and co-incubated with the enzyme (hPL)-substrate system for screening the anti-hPL potentials. To ensure complete mixing of solution and diluent during continuous dilution, we established a numerical simulation model and conducted an ink mixing experiment to determine the mixing time. Furthermore, we also demonstrated the serial dilution ability of the proposed SlipChip using standard fluorescent dye. As a proof of concept, we tested this microfluidic SlipChip using one marketed anti-obesity drug (Orlistat) and two natural products (1,2,3,4,6-penta-O-galloyl-β-D-glucopyranose (PGG) and sciadopitysin) with anti-hPL potentials. The IC50 values of these agents were calculated as 11.69 nM, 8.22 nM and 0.80 μM, for Orlistat, PGG and sciadopitysin, respectively, which were consistent with the results obtained by conventional biochemical assay.
- 15 February 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (2) , 274
Open AccessConstruction and Manipulation of Serial Gradient Dilution Array on a Microfluidic Slipchip for Screening and Characterizing Inhibitors against Human Pancreatic Lipase
Obesity is one of the foremost public health concerns. Human pancreatic lipase (hPL), a crucial digestive enzyme responsible for the digestion of dietary lipids in humans, has been validated as an important therapeutic target for preventing and treating obesity. The serial dilution technique is commonly used to generate solutions with different concentrations and can be easily modified for drug screening. Conventional serial gradient dilution is often performed with tedious multiple manual pipetting steps, where it is difficult to precisely control fluidic volumes at low microliter levels. Herein, we presented a microfluidic SlipChip that enabled formation and manipulation of serial dilution array in an instrument-free manner. With simple slipping steps, the compound solution could be diluted to seven gradients with the dilution ratio of 1:1 and co-incubated with the enzyme (hPL)-substrate system for screening the anti-hPL potentials. To ensure complete mixing of solution and diluent during continuous dilution, we established a numerical simulation model and conducted an ink mixing experiment to determine the mixing time. Furthermore, we also demonstrated the serial dilution ability of the proposed SlipChip using standard fluorescent dye. As a proof of concept, we tested this microfluidic SlipChip using one marketed anti-obesity drug (Orlistat) and two natural products (1,2,3,4,6-penta-O-galloyl-β-D-glucopyranose (PGG) and sciadopitysin) with anti-hPL potentials. The IC50 values of these agents were calculated as 11.69 nM, 8.22 nM and 0.80 μM, for Orlistat, PGG and sciadopitysin, respectively, which were consistent with the results obtained by conventional biochemical assay.