Yue Di
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yue Di has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Chi Cheng
Department of Ophthalmology, Shanghai Children's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200062, China
2 shared publicationsHao Wu
Department of Ophthalmology, Shanghai Children's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200062, China
2 shared publicationsTing Wan
Department of Ophthalmology, Jinshan Hospital, Fudan University, Shanghai 201508, China
2 shared publications- Tong Qiao
School of Medicine, Department of Ophthalmology, Shanghai Children' s Hospital, Shanghai Jiao Tong University city, Shanghai, 200062, China.
2 shared publications Wenting Luo
School of Medicine, Department of Ophthalmology, Shanghai Children' s Hospital, Shanghai Jiao Tong University city, Shanghai, 200062, China
2 shared publicationsHan Ye
Department of Ophthalmology, Shanghai Children’s Hospital, School of medicine, Shanghai Jiaotong University, Shanghai, China
1 shared publication
Latest Publications
- Open Access
- 18 February 2026
- Published by Press of International Journal of Ophthalmology (IJO Press) in International Journal of Ophthalmology
- Vol. 19 (2) , 211-218
Pharmacological and light-driven pupillary accommodation in guinea pigs: comparative effects of muscarinic modulators and illumination across developmental stages
AIM: To investigate the effects of different light intensities and various mydriatic and miotic drugs on pupil accommodation in guinea pigs. METHODS: Forty-two-week-old guinea pigs were randomly divided into four groups to assess pupillary responses under varying light intensities (100, 250, 500 lx) and pharmacological interventions (1% atropine, 1% cyclopentolate, 1% tropicamide, or 2% pilocarpine). Baseline pupil size and eccentricity were recorded using a non-contact Python-based imaging system integrating edge detection and pixel-to-distance conversion. Direct illumination effects were measured at sequential time points, followed by drug administration and longitudinal tracking of pupillary changes. The protocol was repeated at 12wk of age for developmental comparisons. Post-experiment, enucleated eyes were analyzed to evaluate in vitro vs in vivo differences. RESULTS: Significant age-dependent differences in pupil dynamics were observed. Both 2- and 12-week-old guinea pigs exhibited marked pupil constriction under direct illumination (P<0.001), with decreased eccentricity post-constriction (P<0.001). Indirect illumination caused inconsistent pupil size changes (2-week: P=0.68; 12-week: P=0.49). Pharmacologically, atropine, cyclopentolate, and tropicamide induced pupil dilation (P<0.001), whereas pilocarpine caused constriction (P<0.001). All drug groups showed reduced eccentricity (P<0.001). In vivo/in vitro comparisons revealed significant structural differences. CONCLUSION: This study investigates pupillary responses in developing guinea pigs, revealing a direct pupillary light reflex (PLR) with light intensity-dependent responses, while indirect PLR was undetectable. The differential effects of muscarinic modulators on pupillary responses underscore the critical role of cholinergic signaling in ocular accommodation, with age-related variations in sensitivity. Additionally, a novel non-contact measurement methodology achieved a precision of 0.01 mm for pupillary quantification, enhancing accuracy in ocular studies.
- 18 February 2026
- Published by Press of International Journal of Ophthalmology (IJO Press) in International Journal of Ophthalmology
- Vol. 19 (2) , 211-218
Open AccessPharmacological and light-driven pupillary accommodation in guinea pigs: comparative effects of muscarinic modulators and illumination across developmental stages
AIM: To investigate the effects of different light intensities and various mydriatic and miotic drugs on pupil accommodation in guinea pigs. METHODS: Forty-two-week-old guinea pigs were randomly divided into four groups to assess pupillary responses under varying light intensities (100, 250, 500 lx) and pharmacological interventions (1% atropine, 1% cyclopentolate, 1% tropicamide, or 2% pilocarpine). Baseline pupil size and eccentricity were recorded using a non-contact Python-based imaging system integrating edge detection and pixel-to-distance conversion. Direct illumination effects were measured at sequential time points, followed by drug administration and longitudinal tracking of pupillary changes. The protocol was repeated at 12wk of age for developmental comparisons. Post-experiment, enucleated eyes were analyzed to evaluate in vitro vs in vivo differences. RESULTS: Significant age-dependent differences in pupil dynamics were observed. Both 2- and 12-week-old guinea pigs exhibited marked pupil constriction under direct illumination (P<0.001), with decreased eccentricity post-constriction (P<0.001). Indirect illumination caused inconsistent pupil size changes (2-week: P=0.68; 12-week: P=0.49). Pharmacologically, atropine, cyclopentolate, and tropicamide induced pupil dilation (P<0.001), whereas pilocarpine caused constriction (P<0.001). All drug groups showed reduced eccentricity (P<0.001). In vivo/in vitro comparisons revealed significant structural differences. CONCLUSION: This study investigates pupillary responses in developing guinea pigs, revealing a direct pupillary light reflex (PLR) with light intensity-dependent responses, while indirect PLR was undetectable. The differential effects of muscarinic modulators on pupillary responses underscore the critical role of cholinergic signaling in ocular accommodation, with age-related variations in sensitivity. Additionally, a novel non-contact measurement methodology achieved a precision of 0.01 mm for pupillary quantification, enhancing accuracy in ocular studies.
- Open Access
- 17 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 30049
Digital measurement of pupil size, corneal size, and eccentricity in Guinea pigs using python compared with traditional OCT
To develop a Python-based digital technique for accurate measurement of pupil size, corneal size, and eccentricity in guinea pigs, and to validate its efficiency and accuracy against traditional OCT methods in ophthalmology research. Fourteen healthy guinea pigs were selected, and the eye images were captured using a camera, and the image analysis program was written by Python 3.9. The program integrated edge detection (Canny algorithm), curve fitting (conic curve equation) and pixel-actual distance conversion modules, and designed a graphical user interface (GUI) to visualize the operation. Measured parameters included pupil size, corneal size and eccentricity to compare the difference between in vivo and ex vivo measurements and to verify the accuracy of the method. The Python program clearly identified the guinea pig pupil and corneal limbus, and the fitted curves were in high agreement with the actual contours. Pupil and corneal size measured with an accuracy of 0.01 mm. In vivo and in vitro measurements showed that pupil size increased significantly after ex vivo (p < 0.001), whereas there was no significant difference in eccentricity (p = 0.38). Compared to optical coherence tomography (OCT), the method did not differ significantly in accuracy (p > 0.05), but significantly improved efficiency and reduced reliance on specialized equipment. The Python-based digital measurement technique can effectively and accurately quantify the morphological parameters of the guinea pig eye, providing reliable technical support for non-contact measurements in experimental animals.
- 17 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 30049
Open AccessDigital measurement of pupil size, corneal size, and eccentricity in Guinea pigs using python compared with traditional OCT
To develop a Python-based digital technique for accurate measurement of pupil size, corneal size, and eccentricity in guinea pigs, and to validate its efficiency and accuracy against traditional OCT methods in ophthalmology research. Fourteen healthy guinea pigs were selected, and the eye images were captured using a camera, and the image analysis program was written by Python 3.9. The program integrated edge detection (Canny algorithm), curve fitting (conic curve equation) and pixel-actual distance conversion modules, and designed a graphical user interface (GUI) to visualize the operation. Measured parameters included pupil size, corneal size and eccentricity to compare the difference between in vivo and ex vivo measurements and to verify the accuracy of the method. The Python program clearly identified the guinea pig pupil and corneal limbus, and the fitted curves were in high agreement with the actual contours. Pupil and corneal size measured with an accuracy of 0.01 mm. In vivo and in vitro measurements showed that pupil size increased significantly after ex vivo (p < 0.001), whereas there was no significant difference in eccentricity (p = 0.38). Compared to optical coherence tomography (OCT), the method did not differ significantly in accuracy (p > 0.05), but significantly improved efficiency and reduced reliance on specialized equipment. The Python-based digital measurement technique can effectively and accurately quantify the morphological parameters of the guinea pig eye, providing reliable technical support for non-contact measurements in experimental animals.
- 16 January 2023
- Published by Taylor & Francis in Current Eye Research
- Vol. 48 (5) , 465-473
Development and Validation of a Simple Nomogram for Predicting Rapid Myopia Progression in Children with Orthokeratology Management
To develop and validate an ideal nomogram and an online calculator for predicting rapid myopia progression risk in children managed with orthokeratology (ortho-k).Data of children undergoing ortho-...
- 16 January 2023
- Published by Taylor & Francis in Current Eye Research
- Vol. 48 (5) , 465-473
Development and Validation of a Simple Nomogram for Predicting Rapid Myopia Progression in Children with Orthokeratology Management
To develop and validate an ideal nomogram and an online calculator for predicting rapid myopia progression risk in children managed with orthokeratology (ortho-k).Data of children undergoing ortho-...