MRMadhavan L. Raghavan

Madhavan L. Raghavan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Madhavan L. Raghavan has a total of 81 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Lobar Sliding Reduces Parenchymal Distortion More in the Right Lung Than the Left Lung

    by Adam E. Galloy, Joseph M. Reinhardt, Madhavan L. Raghavan

    Interlobar sliding has long been suspected to help the lungs adapt to changes in thoracic cavity shape by reducing parenchymal distortion. Our previous controlled computational experiment tested the hypothesis that lung lobar sliding reduces parenchymal distortion during breathing, but only the left lung was studied. The goal of this study was to extend this analysis to the right lung which has three lobes and two fissures compared to the left lung's two lobes and single fissure. Finite elastic contact mechanics models of the right lung were used to perform paired subject-specific simulations of lung deformation with and without lobar sliding from end inhale to end exhale at both tidal breathing volumes (n = 8) and breath hold volumes near total lung capacity and functional residual capacity (n = 6). Consistent with the hypothesis, we found that parenchymal distortion, quantified with the spatial mean of the anisotropic deformation index (ADI) throughout each lung model, was lesser in the models with lobar sliding than their nonsliding counterparts (p = 0.008, 13% median difference for tidal breathing and p = 0.03, 19.6% median difference for breath holds). This effect was several times larger than was previously observed in the left lung (p = 0.008, 5.3% median difference for tidal breathing and p = 0.03, 3.2% median difference for breath holds), likely due to the greater number of sliding interfaces in the right lung than the left which better allow the right lung to adapt to the thoracic cavity.


  • A Comparative Study of Machine Learning and Algorithmic Approaches to Automatically Identify the Yield Point in Normal and Aneurysmal Human Aortic Tissues

    by Timothy K. Chung, Joseph Kim, Pete H. Gueldner, David. A. Vorp, Madhavan L. Raghavan

    The stress–strain curve of biological soft tissues helps characterize their mechanical behavior. The yield point on this curve is when a specimen breaches its elastic range due to irreversible microstructural damage. The yield point is easily found using the offset yield method in traditional engineering materials. However, correctly identifying the yield point in soft tissues can be subjective due to its nonlinear material behavior. The typical method for yield point identification is visual inspection, which is investigator-dependent and does not lend itself to automation of the analysis pipeline. An automated algorithm to identify the yield point objectively assesses soft tissues' biomechanical properties. This study aimed to analyze data from uniaxial extension testing on biological soft tissue specimens and create a machine learning (ML) model to determine a tissue sample's yield point. We present a trained machine learning model from 279 uniaxial extension curves from testing aneurysmal/nonaneurysmal and longitudinal/circumferential oriented tissue specimens that multiple experts labeled through an adjudication process. The ML model showed a median error of 5% in its estimated yield stress compared to the expert picks. The study found that an ML model could accurately identify the yield point (as defined) in various aortic tissues. Future studies will be performed to validate this approach by visually inspecting when damage occurs and adjusting the model using the ML-based approach.


  • Role of lung lobar sliding on parenchymal distortion during breathing

    by Adam E. Galloy, Joseph M. Reinhardt, Madhavan L. Raghavan

    The role of lobar sliding in lung mechanics is poorly understood. Delineating this role could help explain how breathing is affected by anatomical differences between subjects such as incomplete and missing lobar fissures. We used computational contact mechanics models of lungs from human subjects to delineate the effect of lobar sliding by comparing simulations that allowed and disallowed sliding. We found evidence consistent with the hypothesis that lung lobar sliding reduces parenchymal distortion during breathing.


  • Flow Monitoring of ECMO Circuit for Detecting Oxygenator Obstructions

    by Srivats Sarathy, Joseph W. Turek, Jian Chu, Aditya Badheka, Marco A. Nino, M. L. Raghavan

    Oxygenator thrombosis during extracorporeal membrane oxygenation (ECMO), is a complication that necessitates component replacement. ECMO centers monitor clot burden by intermittent measurement of pressure drop across the oxygenator. An increase in pressure drop at a preset flow rate suggests an increase in resistance/clot formation within the oxygenator. This monitoring method comes with inherent disadvantages such as monitoring gaps, and increased risk of air embolism and infection. We explored utilizing flow measurement, which avoids such risks, as an indicator of ECMO circuit obstructions. The hypothesis that flow rate through a shunt tube in the circuit will increase as distal resistances in the circuit increases was tested. We experimentally simulated controlled levels of oxygenator obstructions using glass microspheres in an ex vivo veno-venous ECMO circuit and measured the change in shunt flow rate using over the tube ultra-sound flow probes. A mathematical model was also used to study the effect of distal resistances in the ECMO circuit on shunt flow. Results of both the mathematical model and the experiments showed a clear and measurable increase in shunt flow with increasing levels of oxygenator obstruction. Therefore, flow monitoring appears to be an effective non-contact and continuous method to monitor for obstruction during ECMO.


  • Open Access

    Electrochemical Approach to Measure Physiological Fluid Flow Rates

    by Srivats Sarathy, Marco A. Nino, Abdulsattar H. Ghanim, Srinivasan Rajagopal, Syed Mubeen, M. L. Raghavan

    In vivo measurement of the flow rate of physiological fluids such as the blood flow rate in the heart is vital in critically ill patients and for those undergoing surgical procedures. The reliability of these measurements is therefore quite crucial. However, current methods in practice for measuring flow rates of physiological fluids suffer from poor repeatability and reliability. Here, we assessed the feasibility of a flow rate measurement method that leverages time transient electrochemical behavior of a tracer that is injected directly into a medium (the electrochemical signal caused due to the tracer injectate will be diluted by the continued flow of the medium and the time response of the current—the electrodilution curve—will depend on the flow rate of the medium). In an experimental flow loop apparatus equipped with an electrochemical cell, we used the AC voltammetry technique and tested the feasibility of electrodilution-based measurement of the flow rate using two mediums—pure water and anticoagulated blood—with 0.9 wt% saline as the injectate. The electrodilution curve was quantified using three metrics—change in current amplitude, total time, and change in the total charge for a range of AC voltammetry settings (peak voltages and frequencies). All three metrics showed an inverse relationship with the flow rate of water and blood, with the strongest negative correlation obtained for change in current amplitude. The findings are a proof of concept for the electrodilution method of the flow rate measurement and offer the potential for physiological fluid flow rate measurement in vivo.


  • Investigation of the Observed Rupture Lines in Abdominal Aortic Aneurysms Using Crack Propagation Simulations

    by S. Attarian, S. Xiao, T. C. Chung, E. S. da Silva, M. L. Raghavan

    The objective of the study is to use crack propagation simulation to study the rupture site characteristics in ruptured abdominal aortic aneurysms (AAA). In a study population of four ruptured AAA harvested whole from cadavers, the rupture lines were precisely documented. The wall properties such as thickness and material parameters were experimentally determined. Using subject-specific three-dimensional (3D) geometry and a finite elastic isotropic material model with subject-specific parameters, crack propagation simulations were conducted based on basic fracture mechanics principles to investigate if and how localized weak spots may have led to the rupture lines observed upon harvest of ruptured AAA. When an initial crack was imposed at the site of peak wall stress, the propagated path did not match the observed rupture line. This indicates that in this study population, the peak wall stress was unlikely to have caused the observed rupture. When cracks were initiated at random locations in the AAA along random orientations and for random initial lengths, the orientation of the resulting propagated rupture line was always longitudinal. This suggests that the AAA morphology predisposes the AAA to rupture longitudinally, which is consistent with observations. And finally, it was found that, in this study population, rupture may have initiated at short segments of less than 1 cm length that then propagated to the observed rupture lines. This finding provides some guidance for the spatial resolution (approx. 1 cm) of weak spots to investigate for in AAA during ex vivo experimental and in vivo elastography studies. The small study population and lack of a reliable failure model for AAA tissue make these findings preliminary.


  • Efficacy of Flow Monitoring During ECMO

    by Aditya Badheka, Sara E. Stucker, Joseph W. Turek, Madhavan L. Raghavan

    The hypothesis that blood flow monitoring could serve as an effective early indicator of distal obstruction during extracorporeal membrane oxygenation (ECMO) was tested under controlled experimental conditions. The ECMO circuit typically includes (or could be easily modified to include) a shunt that bifurcates from the main line returning a small amount of blood to the pump with access points for drug infusions. Distal circuit obstructions in the oxygenator and beyond will result in an increased diversion of flow from the distal line to the shunt. Thus, elevations in flow through the shunt can serve as a marker for distal circuit obstruction. An ECMO training circuit was adapted with a resistance chamber that simulates controlled and varying levels of distal obstructions. Experiments were conducted under pediatric and adult pump target flow rates simulating different levels of distal obstructions while documenting the shunt flow and pressure drop across the obstruction. There was measurable and statistically significant elevation in the shunt flow at all flow rates because of different levels of obstruction from baseline values and hence consistent with the hypothesis that shunt flow can serve as an indicator of distal obstruction in the ECMO circuit. Flow monitoring is over the tube, hands free, continuous, and easy to implement. Therefore, it has the potential to serve as an early nonspecific indicator of elevated distal resistance in the ECMO circuit, which can then trigger other measurements (such as pressure drop across the oxygenator) for a more specific assessment of the source for distal resistance.


  • Open Access

    Volumetry and biomechanical parameters detected by 3D and 2D ultrasound in patients with and without an abdominal aortic aneurysm

    by Nayara Cioffi Batagini, Carlos Augusto Pinto Ventura, Madhavan L Raghavan, Maria Cristina Chammas, Adriano Tachibana, Erasmo Simão da Silva

    The objective was to demonstrate the ability of ultrasound (US) with 3D properties to evaluate volumetry and biomechanical parameters of the aorta in patients with and without abdominal aortic aneurysm (AAA). Thirty-one patients with normal aortas (group 1), 46 patients with AAA measuring 3.0–5.5 cm (group 2) and 31 patients with AAA ⩾ 5.5 cm (group 3) underwent a 2D/3D-US examination of the infra-renal aorta, and the images were post-processed prior to being analyzed. In the maximum diameter, the global circumferential strain and the global maximum rotation assessed by 2D speckle-tracking algorithms were compared among the three groups. The volumetry data obtained using 3D-US from 40 AAA patients were compared with the volumetry data obtained by a contemporary computed tomography (CT) scan. The median global circumferential strain was 2.0% (interquartile range (IR): 1.0–3.0), 1.0% (IR: 1.0–2.0) and 1.0% (IR: 1.0–1.75) in groups 1, 2 and 3, respectively ( p < 0.001). The median global maximum rotation decreased progressively from group 1 to group 3 (1.38º (IR: 0.77–2.13), 0.80º (IR: 0.57–1.0) and 0.50º (IR: 0.31–0.75), p < 0.001). AAA volume estimations by 3D-US correlated well with CT ( R 2 = 0.76). In conclusion, US with 3D properties is non-invasive and has the potential to evaluate volumetry and biomechanical characteristics of AAA.


  • Aneurysm Shape Reconstruction from Biplane Angiograms in the ISUIA Collection

    by Madhavan L. Raghavan, for the International Study of Unruptured Intracranial Aneurysms Investigators, Gaurav V. Sharda, John Huston, J Mocco, Ana W. Capuano, James C. Torner, Punam K. Saha, Irene Meissner, Robert D. Brown

    The International Study of Unruptured Intracranial Aneurysms (ISUIA) is an epidemiologic international study of the natural history of unruptured intracranial aneurysms that enrolled 4,060 subjects. A conventional biplane cerebral angiogram available for central review was required for enrollment resulting in a large database. Data on aneurysms that ruptured during follow-up of the 1,692 untreated subjects provides an opportunity to investigate the anatomic features that may be predictive of future rupture. The objective of the study is to develop and test a method for three-dimensional (3D) shape reconstruction of aneurysms using biplane angiographic data in the ISUIA for retrospective morphometric assessment. Beginning with the two boundaries of the biplane views, curve morphing techniques were employed to estimate a number of intermediate boundaries around the aneurysm sac resulting in the creation of a 3D sac surface. The method was tested using simulated biplane “angiograms” of pre-reconstructed 3D models of patient-specific aneurysms. An algorithm to perform the image analysis was developed, and the morphometric indices of 150 intracranial aneurysms in the ISUIA database were estimated. Simultaneously, experienced neuroradiologists made manual measurements of key dimensions in the sac from the biplane angiograms for all cases. 3D reconstructions using our proposed method matched well with the original pre-reconstructed 3D geometries and were consistent with manual measurements of the neuroradiologists for the ISUIA aneurysms. A method for reconstructing the 3D geometry of the intracranial aneurysm sac from biplane angiograms in the ISUIA database with reasonable fidelity has been developed.