GPGwang-Min Park

Gwang-Min Park

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gwang-Min Park has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Dae Hyun Kim

    Department of Physical and Rehabilitation Medicine, Center for Prevention and Rehabilitation, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea

    1 shared publication
  • Ji Cheol Shin

    Department and Research Institute of Rehabilitation Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea

    1 shared publication
  • Juntaek Hong

    Department and Research Institute of Rehabilitation Medicine, Yonsei University College of Medicine, Seoul, Korea

    1 shared publication
  • Su-Hyun Cho

    Department and Research Institute of Rehabilitation Medicine, Yonsei University College of Medicine, Seoul 03722, Republic of Korea

    1 shared publication

Latest Publications

  • Open Access

    Effects and Safety of Wearable Exoskeleton for Robot-Assisted Gait Training: A Retrospective Preliminary Study

    by Gwang-Min Park, Su-Hyun Cho, Jun-Taek Hong, Dae-Hyun Kim, Ji-Cheol Shin

    Background: Wearable devices for robot-assisted gait training (RAGT) provide overground gait training for the rehabilitation of neurological injuries. We aimed to evaluate the effectiveness and safety of RAGT in patients with a neurologic deficit. Methods: Twenty-eight patients receiving more than ten sessions of overground RAGT using a joint-torque-assisting wearable exoskeletal robot were retrospectively analyzed in this study. Nineteen patients with brain injury, seven patients with spinal cord injury and two patients with peripheral nerve injury were included. Clinical outcomes, such as the Medical Research Council scale for muscle strength, Berg balance scale, functional ambulation category, trunk control tests, and Fugl–Meyer motor assessment of the lower extremities, were recorded before and after RAGT. Parameters for RAGT and adverse events were also recorded. Results: The Medical Research Council scale scores for muscle strength (36.6 to 37.8), Berg balance scale (24.9 to 32.2), and functional ambulation category (1.8 to 2.7) significantly improved after overground RAGT (p < 0.05). The familiarization process was completed within six sessions of RAGT. Only two mild adverse events were reported. Conclusions: Overground RAGT using wearable devices can improve muscle strength, balance, and gait function. It is safe in patients with neurologic injury.