Yuan Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuan Gao has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jianian Li
Faculty of Modern Agricultural Engineering, Kunming University of Science and Technology, Kunming 650500, China
2 shared publications - Chenglin Wang
Faculty of Modern Agricultural Engineering, Kunming University of Science and Technology, Kunming 650504, China
1 shared publication - Guoxuan Wang
Faculty of Modern Agricultural Engineering, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication - Jiawen Liang
Faculty of Modern Agricultural Engineering, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication - Jingyuan Zeng
Guangdong Provincial Key Laboratory of Conservation and Precision Utilization of Characteristic Agricultural Resources in Mountainous Areas, College of Computer Science, Jiaying University, Meizhou 514015, China
1 shared publication - Xing Li
Faculty of Modern Agricultural Engineering, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication
Latest Publications
- Open Access
- 5 August 2024
- Published by MDPI AG in Agriculture
- Vol. 14 (8) , 1291
Spectrophotometric-Based Sensor for the Detection of Multiple Fertilizer Solutions
The online detection of fertilizer solution information is a crucial link in the implementation of intelligent and precise variable fertilization techniques. However, achieving simultaneous rapid online detection of multiple fertilizer components is still challenging. Therefore, a rapid detection method based on spectrophotometry for qualitative and quantitative identification of four fertilizers (typical N, P, and K fertilizers: KNO3, (NH4)2SO4, KH2PO4, and K2SO4) was proposed in this work. Full-scan absorption spectra of fertilizer solutions at varying concentrations were obtained using a UV–visible/near-infrared spectrophotometer. By assessing the linear fit between fertilizer concentration and absorbance at each wavelength within the characteristic band, the characteristic wavelengths for KNO3, (NH4)2SO4, KH2PO4, and K2SO4 were identified as 214 nm, 410 nm, 712 nm, and 1708 nm, respectively. The identification method of fertilizer type and the prediction model of concentration were constructed based on characteristic wavelength and the Lambert–Beer law. Based on the above analysis, a four-channel photoelectric sensor was designed with four LEDs emitting wavelengths closely matched to characteristic wavelengths for fertilizer detection. A detection strategy of “qualitative analysis followed by quantitative detection” was proposed to realize the online detection of four fertilizer types and their concentrations. Evaluation of the sensor’s performance showed its high stability, with an accuracy of 81.5% in recognizing fertilizer types. Furthermore, the relative error of the sensor detection was substantially less than ±15% for the fertilizer concentrations not exceeding 80 mg/L. These results confirm the capability of the sensor to meet the practical requirements for online detection of four fertilizer types and concentrations in the field of agricultural engineering.
- 5 August 2024
- Published by MDPI AG in Agriculture
- Vol. 14 (8) , 1291
Open AccessSpectrophotometric-Based Sensor for the Detection of Multiple Fertilizer Solutions
The online detection of fertilizer solution information is a crucial link in the implementation of intelligent and precise variable fertilization techniques. However, achieving simultaneous rapid online detection of multiple fertilizer components is still challenging. Therefore, a rapid detection method based on spectrophotometry for qualitative and quantitative identification of four fertilizers (typical N, P, and K fertilizers: KNO3, (NH4)2SO4, KH2PO4, and K2SO4) was proposed in this work. Full-scan absorption spectra of fertilizer solutions at varying concentrations were obtained using a UV–visible/near-infrared spectrophotometer. By assessing the linear fit between fertilizer concentration and absorbance at each wavelength within the characteristic band, the characteristic wavelengths for KNO3, (NH4)2SO4, KH2PO4, and K2SO4 were identified as 214 nm, 410 nm, 712 nm, and 1708 nm, respectively. The identification method of fertilizer type and the prediction model of concentration were constructed based on characteristic wavelength and the Lambert–Beer law. Based on the above analysis, a four-channel photoelectric sensor was designed with four LEDs emitting wavelengths closely matched to characteristic wavelengths for fertilizer detection. A detection strategy of “qualitative analysis followed by quantitative detection” was proposed to realize the online detection of four fertilizer types and their concentrations. Evaluation of the sensor’s performance showed its high stability, with an accuracy of 81.5% in recognizing fertilizer types. Furthermore, the relative error of the sensor detection was substantially less than ±15% for the fertilizer concentrations not exceeding 80 mg/L. These results confirm the capability of the sensor to meet the practical requirements for online detection of four fertilizer types and concentrations in the field of agricultural engineering.
- Open Access
Online Rapid Detection Method of Fertilizer Solution Information Based on Characteristic Frequency Response Features
Online rapid detection of a fertilizer solution’s type and concentration is crucial for intelligent water and fertilizer machines to realize intellectual precision variable fertilization. In this paper, a cylindrical capacitance sensor was designed based on the dielectric properties of the fertilizer solution, and an online rapid detection method of fertilizer type and concentration was proposed based on the characteristic frequency response mode. Three fertilizer solutions, potassium chloride, calcium superphosphate, and urea, were used as test objects. Ten concentrations of each fertilizer solution in the 10~100 g/L range were taken as the test fertilizer solution. Then, under the action of a series of sine wave excitation signals from 1 kHz to 10 MHz, the sensor’s amplitude-frequency/phase-frequency response data were obtained. The detection strategy of ‘first type, then concentration’ was adopted to realize rapid online detection of fertilizer type and concentration. Experimental results indicated that the maximum relative error of the sensor stability test was 0.72%, and the maximum error of concentration detection was 7.26%. Thus, the intelligent water and fertilizer machine can give feedback on the information of a fertilizer solution in real-time during the process of precise variable fertilization, thus improving the intelligence of water and fertilizer machines.
Open AccessOnline Rapid Detection Method of Fertilizer Solution Information Based on Characteristic Frequency Response Features
Online rapid detection of a fertilizer solution’s type and concentration is crucial for intelligent water and fertilizer machines to realize intellectual precision variable fertilization. In this paper, a cylindrical capacitance sensor was designed based on the dielectric properties of the fertilizer solution, and an online rapid detection method of fertilizer type and concentration was proposed based on the characteristic frequency response mode. Three fertilizer solutions, potassium chloride, calcium superphosphate, and urea, were used as test objects. Ten concentrations of each fertilizer solution in the 10~100 g/L range were taken as the test fertilizer solution. Then, under the action of a series of sine wave excitation signals from 1 kHz to 10 MHz, the sensor’s amplitude-frequency/phase-frequency response data were obtained. The detection strategy of ‘first type, then concentration’ was adopted to realize rapid online detection of fertilizer type and concentration. Experimental results indicated that the maximum relative error of the sensor stability test was 0.72%, and the maximum error of concentration detection was 7.26%. Thus, the intelligent water and fertilizer machine can give feedback on the information of a fertilizer solution in real-time during the process of precise variable fertilization, thus improving the intelligence of water and fertilizer machines.
- 20 October 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12350, 685-691
Algorithm research for prize-collecting dominating set problem on special graph
The prize-collecting dominating set (PCDS) problem is the generalization of the minimum dominating set (MDS) problem. The MDS problem requires a dominating set in a given graph, namely a subset of vertexes. Any vertex in the graph belongs to the closed neighborhood of the subset of vertexes, where the subset of vertexes with the smallest cardinality is the MDS. In the PCDS problem: given an undirected graph, its vertex setV has nonnegative weighting functionω and nonnegative penalty functionπ . Finding a vertex subset D⊂V, for vertexes do not belong to the closed neighborhood of D , we need to pay penalties for them. The objective of this issue is to minimize the sum of weights and penalties. As we all know that the MDS problem is NP-hard in general graph, obviously, PCDS problem is NP-hard, too., In certain cases, the PCDS problem can achieve better results than the MDS problem, which has a certain value in practical applications such as facility location and logistics management. Whether the problem is limited to a special graph will get useful structural characterization and corresponding algorithm results is considered, designed polynomial time exact algorithm on the star and according to the r -LMP approximation algorithm, designed the 2-LMP approximation algorithm on the path and cycle.
- 20 October 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12350, 685-691
Algorithm research for prize-collecting dominating set problem on special graph
The prize-collecting dominating set (PCDS) problem is the generalization of the minimum dominating set (MDS) problem. The MDS problem requires a dominating set in a given graph, namely a subset of vertexes. Any vertex in the graph belongs to the closed neighborhood of the subset of vertexes, where the subset of vertexes with the smallest cardinality is the MDS. In the PCDS problem: given an undirected graph, its vertex setV has nonnegative weighting functionω and nonnegative penalty functionπ . Finding a vertex subset D⊂V, for vertexes do not belong to the closed neighborhood of D , we need to pay penalties for them. The objective of this issue is to minimize the sum of weights and penalties. As we all know that the MDS problem is NP-hard in general graph, obviously, PCDS problem is NP-hard, too., In certain cases, the PCDS problem can achieve better results than the MDS problem, which has a certain value in practical applications such as facility location and logistics management. Whether the problem is limited to a special graph will get useful structural characterization and corresponding algorithm results is considered, designed polynomial time exact algorithm on the star and according to the r -LMP approximation algorithm, designed the 2-LMP approximation algorithm on the path and cycle.