HZHao Zhong

Hao Zhong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hao Zhong has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Anni Deng

    Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China

    1 shared publication
  • Guoliang Huang

    School of Biomedical Engineering, Tsinghua University, Beijing, 100084, China; National Engineering Research Center for Beijing Biochip Technology, Beijing, 102206, China

    1 shared publication
  • Han Yang

    Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China

    1 shared publication
  • Lei Zhang

    Department of Obstetrics and Gynecology, Beijing TsingHua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, China

    1 shared publication
  • Leyang Huang

    Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China

    1 shared publication
  • Meng Li

    Department of Obstetrics and Gynecology, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing 102218, China

    1 shared publication

Latest Publications

  • Open Access

    An Integrated and Multi-Target Nucleic Acid Isothermal Analysis System for Rapid Diagnosis of Vulvovaginal Candidiasis

    by Xiangyu Jin, Meng Li, Zeyin Mao, Anni Deng, Wenqi Lv, Leyang Huang, Hao Zhong, Han Yang, Lei Zhang, Qinping Liao, et al.

    Rapid identification of Candida species is significant for the diagnosis of vulvovaginal candidiasis (VVC). An integrated and multi-target system for the rapid, high-specificity, and high-sensitivity detection of four Candida species was developed. The system consists of a rapid sample processing cassette and a rapid nucleic acid analysis device. The cassette could process the Candida species to release nucleic acids in 15 min. The released nucleic acids were analyzed by the device as fast as within 30 min, using the loop-mediated isothermal amplification method. The four Candida species could be simultaneously identified, with each reaction using only 1.41 µL of reaction mixture, which was low cost. The RPT (rapid sample processing and testing) system could detect the four Candida species with high sensitivity (90 days, and the system could also be used for the detection of bacteria.