Mark Phillips
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mark Phillips has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Aarti Nandani
Clinical Trials Pharmacy, Royal Free London NHS Foundation Trust, London NW3 2QG, UK
2 shared publications - Ahmed Abdelaal Ahmed Mahmoud Metwally Alkhatip
Department of Anaesthesia, Birmingham Children’s Hospital, United Kingdom
2 shared publications - Alison Evans
University College London (UCL)/University College London Hospitals NHS Trust (UCLH) Joint Research Office, London WC1E 6BT, UK
2 shared publications - Ameet Bakhai
Royal Free London NHS Foundation Trust, London, UK
2 shared publications - Amit Chunilal Nathwani
Research Department of Haematology, UCL Cancer Institute, University College London, London, United Kingdom
2 shared publications - Anne Riddell
Katharine Dormandy Haemophilia Centre Royal Free Hospital London UK
2 shared publications
Latest Publications
- Open Access
- 8 September 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (18) , 5848
Nebulized Recombinant Tissue Plasminogen Activator (rt-PA) for Acute COVID-19-Induced Respiratory Failure: An Exploratory Proof-of-Concept Trial
Acute lung injury in COVID-19 results in diffuse alveolar damage with disruption of the alveolar-capillary barrier, coagulation activation, alveolar fibrin deposition and pulmonary capillary thrombi. Nebulized recombinant tissue plasminogen activator (rt-PA) has the potential to facilitate localized thrombolysis in the alveolar compartment and improve oxygenation. In this proof-of-concept safety study, adults with COVID-19-induced respiratory failure and a 2/FiO2 (P/F) ratio requiring invasive mechanical ventilation (IMV) or non-invasive respiratory support (NIRS) received nebulized rt-PA in two cohorts (C1 and C2), alongside standard of care, between 23 April–30 July 2020 and 21 January–19 February 2021, respectively. Matched historical controls (MHC; n = 18) were used in C1 to explore efficacy. Safety co-primary endpoints were treatment-related bleeds and <1.0–1.5 g/L fibrinogen reduction. A variable dosing strategy with clinical efficacy endpoint and minimal safety concerns was determined in C1 for use in C2; patients were stratified by ventilation type to receive 40–60 mg rt-PA daily for ≤14 days. Nine patients in C1 (IMV, 6/9; NIRS, 3/9) and 26 in C2 (IMV, 12/26; NIRS, 14/26) received nebulized rt-PA for a mean (SD) of 6.7 (4.6) and 9.1(4.6) days, respectively. Four bleeds (one severe, three mild) in three patients were considered treatment related. There were no significant fibrinogen reductions. Greater improvements in mean P/F ratio from baseline to study end were observed in C1 compared with MHC (C1; 154 to 299 vs. MHC; 154 to 212). In C2, there was no difference in the baseline P/F ratio of NIRS and IMV patients. However, a larger improvement in the P/F ratio occurred in NIRS patients (NIRS; 126 to 240 vs. IMV; 120 to 188) and fewer treatment days were required (NIRS; 7.86 vs. IMV; 10.5). Nebulized rt-PA appears to be well-tolerated, with a trend towards improved oxygenation, particularly in the NIRS group. Randomized clinical trials are required to demonstrate the clinical effect significance and magnitude.
- 8 September 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (18) , 5848
Open AccessNebulized Recombinant Tissue Plasminogen Activator (rt-PA) for Acute COVID-19-Induced Respiratory Failure: An Exploratory Proof-of-Concept Trial
Acute lung injury in COVID-19 results in diffuse alveolar damage with disruption of the alveolar-capillary barrier, coagulation activation, alveolar fibrin deposition and pulmonary capillary thrombi. Nebulized recombinant tissue plasminogen activator (rt-PA) has the potential to facilitate localized thrombolysis in the alveolar compartment and improve oxygenation. In this proof-of-concept safety study, adults with COVID-19-induced respiratory failure and a 2/FiO2 (P/F) ratio requiring invasive mechanical ventilation (IMV) or non-invasive respiratory support (NIRS) received nebulized rt-PA in two cohorts (C1 and C2), alongside standard of care, between 23 April–30 July 2020 and 21 January–19 February 2021, respectively. Matched historical controls (MHC; n = 18) were used in C1 to explore efficacy. Safety co-primary endpoints were treatment-related bleeds and <1.0–1.5 g/L fibrinogen reduction. A variable dosing strategy with clinical efficacy endpoint and minimal safety concerns was determined in C1 for use in C2; patients were stratified by ventilation type to receive 40–60 mg rt-PA daily for ≤14 days. Nine patients in C1 (IMV, 6/9; NIRS, 3/9) and 26 in C2 (IMV, 12/26; NIRS, 14/26) received nebulized rt-PA for a mean (SD) of 6.7 (4.6) and 9.1(4.6) days, respectively. Four bleeds (one severe, three mild) in three patients were considered treatment related. There were no significant fibrinogen reductions. Greater improvements in mean P/F ratio from baseline to study end were observed in C1 compared with MHC (C1; 154 to 299 vs. MHC; 154 to 212). In C2, there was no difference in the baseline P/F ratio of NIRS and IMV patients. However, a larger improvement in the P/F ratio occurred in NIRS patients (NIRS; 126 to 240 vs. IMV; 120 to 188) and fewer treatment days were required (NIRS; 7.86 vs. IMV; 10.5). Nebulized rt-PA appears to be well-tolerated, with a trend towards improved oxygenation, particularly in the NIRS group. Randomized clinical trials are required to demonstrate the clinical effect significance and magnitude.
- Open Access
- 20 June 2023
- Published by MDPI AG in Preprints.org
Nebulized recombinant tissue plasminogen activator (rt-PA) for acute COVID-19-induced severe respiratory failure: an exploratory proof of concept trial
Nebulized thrombolysis offers locally targeted therapy with potentially lower bleeding risk than systemic administration for coronavirus disease 2019 (COVID-19) respiratory failure. In a proof-of-concept safety study, adult patients with COVID-19-induced respiratory failure and a <300mmHg PaO2/FiO2 (P/F) ratio, requiring invasive mechanical ventilation (IMV) or non-invasive respiratory support (NIRS) received nebulized rt-PA in two cohorts (C1 and C2), alongside standard of care during the first two UK COVID-19 waves. Matched historical controls (MHC; n=18) were used in C1. Safety co-primary endpoints were treatment-related bleeds and fibrinogen reduction to <1.0–1.5 g/L. A dose escalation strategy for improved efficacy with the least safety concerns was determined in C1 for use in C2; patients were stratified by ventilation type to receive 40–60 mg rt-PA per day for ≤14 days. Nine patients in C1 (IMV, 6/9; NIRS, 3/9) and 26 in C2 (IMV, 12/26; NIRS, 14/26) received nebulized rt-PA for a mean (SD) of 6.7 (4.6) and 9.1(4.6) days, respectively. Four bleeding events (one severe and three mild) in three patients were considered treatment-related. No significant fibrinogen reductions were reported. Greater improvement in mean P/F ratio from baseline to end of study was observed in C1 compared with MHC [C1; 154 to 299 vs MHC; 154 to 212). In C2, there was no difference in the baseline P/F ratio of NIRS and IMV patients. However, a larger improvement in P/F ratio was observed in NIRS patients [NIRS; 126 to 240 vs IMV; 120 to 188) and they required fewer treatment days (NIRS; 7.86 vs IMV; 10.5). Nebulized rt-PA appears to be well-tolerated, showing a trend of improved oxygenation and faster recovery in patients with acute COVID-19-induced respiratory failure requiring respiratory support; this effect was more pronounced in the NIRS group. Further investigation is required to study the potential of this novel treatment approach.
- 20 June 2023
- Published by MDPI AG in Preprints.org
Open AccessNebulized recombinant tissue plasminogen activator (rt-PA) for acute COVID-19-induced severe respiratory failure: an exploratory proof of concept trial
Nebulized thrombolysis offers locally targeted therapy with potentially lower bleeding risk than systemic administration for coronavirus disease 2019 (COVID-19) respiratory failure. In a proof-of-concept safety study, adult patients with COVID-19-induced respiratory failure and a <300mmHg PaO2/FiO2 (P/F) ratio, requiring invasive mechanical ventilation (IMV) or non-invasive respiratory support (NIRS) received nebulized rt-PA in two cohorts (C1 and C2), alongside standard of care during the first two UK COVID-19 waves. Matched historical controls (MHC; n=18) were used in C1. Safety co-primary endpoints were treatment-related bleeds and fibrinogen reduction to <1.0–1.5 g/L. A dose escalation strategy for improved efficacy with the least safety concerns was determined in C1 for use in C2; patients were stratified by ventilation type to receive 40–60 mg rt-PA per day for ≤14 days. Nine patients in C1 (IMV, 6/9; NIRS, 3/9) and 26 in C2 (IMV, 12/26; NIRS, 14/26) received nebulized rt-PA for a mean (SD) of 6.7 (4.6) and 9.1(4.6) days, respectively. Four bleeding events (one severe and three mild) in three patients were considered treatment-related. No significant fibrinogen reductions were reported. Greater improvement in mean P/F ratio from baseline to end of study was observed in C1 compared with MHC [C1; 154 to 299 vs MHC; 154 to 212). In C2, there was no difference in the baseline P/F ratio of NIRS and IMV patients. However, a larger improvement in P/F ratio was observed in NIRS patients [NIRS; 126 to 240 vs IMV; 120 to 188) and they required fewer treatment days (NIRS; 7.86 vs IMV; 10.5). Nebulized rt-PA appears to be well-tolerated, showing a trend of improved oxygenation and faster recovery in patients with acute COVID-19-induced respiratory failure requiring respiratory support; this effect was more pronounced in the NIRS group. Further investigation is required to study the potential of this novel treatment approach.