Shiri Zarour
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shiri Zarour has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Or Goren
Division of Anesthesia, Intensive Care and Pain, Tel Aviv Sourasky University Medical Center, Gray Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, Israel
2 shared publications - Amal Khoury
Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
1 shared publication - Anat Reiner-Benaim
Department of Epidemiology, Biostatistics and Community Health Sciences, School of Public Health, Faculty of Health Sciences, Ben Gurion University of the Negev, Beer Sheva, Israel
1 shared publication - Avi Beri
Urology Department, Tel-Aviv Medical Center, Tel-Aviv University, Tel-Aviv 6423906, Israel
1 shared publication - Barak Cohen
Division of Anesthesia, Intensive Care, and Pain Management, Tel-Aviv Medical Center, Tel-Aviv University, Tel-Aviv 6423906, Israel
1 shared publication - Dana Karol
Division of Anesthesia, Intensive Care, and Pain, Tel-Aviv Medical Center, Tel-Aviv University, Tel-Aviv 6423906, Israel
1 shared publication
Latest Publications
- 4 September 2025
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-7
Effect of intraoperative tranexamic acid on blood loss and outcomes in intertrochanteric fractures: a retrospective study of 1728 patients
Purpose To evaluate the effect of intraoperative tranexamic acid (TXA) on perioperative blood loss, transfusion requirements, and clinical outcomes in patients undergoing proximal femoral nailing (PFN) for intertrochanteric fractures. Methods A retrospective cohort study of 1,728 patients who underwent PFN fixation for intertrochanteric fractures between 2017 and 2024. Perioperative hemoglobin (Hb) dynamics, transfusion requirements, and clinical outcomes were compared between patients receiving 1–1.5 g intravenous TXA (n = 1,446) and controls (n = 282). Results The TXA group demonstrated reduced perioperative Hb decline (2.15 ± 1.40 vs 2.76 ± 1.57 g/dL, p < 0.001) and lower rates of Hb drop > 2 g/dL (47.9% vs 63.5%, OR 0.53, p < 0.001). TXA administration was associated with decreased transfusion requirements (7.1% vs 11.0%, p = 0.021). Multivariate analysis confirmed TXA as an independent protective factor against blood loss. Mortality rates showed no significant difference between groups. Conclusion Intraoperative TXA during PFN fixation was associated with reduced perioperative blood loss and transfusion requirements. These findings support TXA as an effective blood conservation strategy in elderly patients with intertrochanteric fractures.
- 4 September 2025
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-7
Effect of intraoperative tranexamic acid on blood loss and outcomes in intertrochanteric fractures: a retrospective study of 1728 patients
Purpose To evaluate the effect of intraoperative tranexamic acid (TXA) on perioperative blood loss, transfusion requirements, and clinical outcomes in patients undergoing proximal femoral nailing (PFN) for intertrochanteric fractures. Methods A retrospective cohort study of 1,728 patients who underwent PFN fixation for intertrochanteric fractures between 2017 and 2024. Perioperative hemoglobin (Hb) dynamics, transfusion requirements, and clinical outcomes were compared between patients receiving 1–1.5 g intravenous TXA (n = 1,446) and controls (n = 282). Results The TXA group demonstrated reduced perioperative Hb decline (2.15 ± 1.40 vs 2.76 ± 1.57 g/dL, p < 0.001) and lower rates of Hb drop > 2 g/dL (47.9% vs 63.5%, OR 0.53, p < 0.001). TXA administration was associated with decreased transfusion requirements (7.1% vs 11.0%, p = 0.021). Multivariate analysis confirmed TXA as an independent protective factor against blood loss. Mortality rates showed no significant difference between groups. Conclusion Intraoperative TXA during PFN fixation was associated with reduced perioperative blood loss and transfusion requirements. These findings support TXA as an effective blood conservation strategy in elderly patients with intertrochanteric fractures.
- Open Access
- 3 April 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (7) , 2072
Utility of NICaS Non-Invasive Hemodynamic Monitoring in Critically Ill Patients with COVID-19
(1) Background: COVID-19 presented many challenges to effective treatments, such as managing cardiovascular insufficiency while mitigating risks to healthcare providers. This study utilized NICaS, a non-invasive hemodynamic monitor that provides advanced data via whole-body impedance analysis. We investigated the associated trends in hemodynamic parameters obtained by the NICaS device and their correlation with in-hospital all-cause mortality during COVID-19 hospitalization in the intensive care unit. (2) Methods: Data from 29 patients with COVID-19 admitted to the intensive care unit and monitored with NICaS between April 2020 and February 2021 were analyzed retrospectively. (3) Results: Decreasing cardiac output and cardiac power were significantly associated with death. Total peripheral resistance was significantly increasing in non-survivors as was total body water percentage. Those admitted with a heart rate above 90 beats per minute had a significantly reduced survival. (4) Conclusions: Non-invasive hemodynamic monitoring via the NICaS device is simple and effective in evaluating critically ill patients with COVID-19 and may help guide clinical management via remote monitoring. Controlling tachycardia may help ensure adequate oxygen supply-demand ratio. A hint toward a beneficiary effect of a restrictive fluid balance may be observed.
- 3 April 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (7) , 2072
Open AccessUtility of NICaS Non-Invasive Hemodynamic Monitoring in Critically Ill Patients with COVID-19
(1) Background: COVID-19 presented many challenges to effective treatments, such as managing cardiovascular insufficiency while mitigating risks to healthcare providers. This study utilized NICaS, a non-invasive hemodynamic monitor that provides advanced data via whole-body impedance analysis. We investigated the associated trends in hemodynamic parameters obtained by the NICaS device and their correlation with in-hospital all-cause mortality during COVID-19 hospitalization in the intensive care unit. (2) Methods: Data from 29 patients with COVID-19 admitted to the intensive care unit and monitored with NICaS between April 2020 and February 2021 were analyzed retrospectively. (3) Results: Decreasing cardiac output and cardiac power were significantly associated with death. Total peripheral resistance was significantly increasing in non-survivors as was total body water percentage. Those admitted with a heart rate above 90 beats per minute had a significantly reduced survival. (4) Conclusions: Non-invasive hemodynamic monitoring via the NICaS device is simple and effective in evaluating critically ill patients with COVID-19 and may help guide clinical management via remote monitoring. Controlling tachycardia may help ensure adequate oxygen supply-demand ratio. A hint toward a beneficiary effect of a restrictive fluid balance may be observed.
- Open Access
Assessment of Intra-Abdominal Pressure with a Novel Continuous Bladder Pressure Monitor—A Clinical Validation Study
Introduction: Intra-abdominal hypertension and the resulting abdominal compartment syndrome are serious complications of severely ill patients. Diagnosis requires an intra-abdominal pressure (IAP) measurement, which is currently cumbersome and underused. We aimed to test the accuracy of a novel continuous IAP monitor. Methods: Adults having laparoscopic surgery and requiring urinary catheter intra-operatively were recruited to this single-arm validation study. IAP measurements using the novel monitor and a gold-standard foley manometer were compared. After anesthesia induction, a pneumoperitoneum was induced through a laparoscopic insufflator, and five randomly pre-defined pressures (between 5 and 25 mmHg) were achieved and simultaneously measured via both methods in each participant. Measurements were compared using Bland–Altman analysis. Results: In total, 29 participants completed the study and provided 144 distinct pairs of pressure measurements that were analyzed. A positive correlation between the two methods was found (R2 = 0.93). There was good agreement between the methods, with a mean bias (95% CI) of −0.4 (−0.6, −0.1) mmHg and a standard deviation of 1.3 mmHg, which was statistically significant but of no clinical importance. The limits of agreement (where 95% of the differences are expected to fall) were −2.9 and 2.2 mmHg. The proportional error was statistically insignificant (p = 0.85), suggesting a constant agreement between the methods across the range of values tested. The percentage error was 10.7%. Conclusions: Continuous IAP measurements using the novel monitor performed well in the clinical setup of controlled intra-abdominal hypertension across the evaluated range of pressures. Further studies should expand the range to more pathological values.
Open AccessAssessment of Intra-Abdominal Pressure with a Novel Continuous Bladder Pressure Monitor—A Clinical Validation Study
Introduction: Intra-abdominal hypertension and the resulting abdominal compartment syndrome are serious complications of severely ill patients. Diagnosis requires an intra-abdominal pressure (IAP) measurement, which is currently cumbersome and underused. We aimed to test the accuracy of a novel continuous IAP monitor. Methods: Adults having laparoscopic surgery and requiring urinary catheter intra-operatively were recruited to this single-arm validation study. IAP measurements using the novel monitor and a gold-standard foley manometer were compared. After anesthesia induction, a pneumoperitoneum was induced through a laparoscopic insufflator, and five randomly pre-defined pressures (between 5 and 25 mmHg) were achieved and simultaneously measured via both methods in each participant. Measurements were compared using Bland–Altman analysis. Results: In total, 29 participants completed the study and provided 144 distinct pairs of pressure measurements that were analyzed. A positive correlation between the two methods was found (R2 = 0.93). There was good agreement between the methods, with a mean bias (95% CI) of −0.4 (−0.6, −0.1) mmHg and a standard deviation of 1.3 mmHg, which was statistically significant but of no clinical importance. The limits of agreement (where 95% of the differences are expected to fall) were −2.9 and 2.2 mmHg. The proportional error was statistically insignificant (p = 0.85), suggesting a constant agreement between the methods across the range of values tested. The percentage error was 10.7%. Conclusions: Continuous IAP measurements using the novel monitor performed well in the clinical setup of controlled intra-abdominal hypertension across the evaluated range of pressures. Further studies should expand the range to more pathological values.